CHECK BATTERY
The device detects an implausible internal resistance of the inserted battery.
Ensure that the battery cap is tightened securely, and the poles of the inserted battery
make contact with the battery cap and the device. Inspect the poles of the inserted battery
as well as the contact points between the battery cap and the device (threads) for dirt or
debris and clean them if needed. This error message may indicate a defective or inferior
battery - if the error message persists even after performing the previous troubleshooting
steps, we strongly recommend replacing the battery promptly and disposing of it properly!
TOO HOT
DNA60C
The device is in safety shutdown mode due to the temperature inside exceeding 75°C.
Immediately remove the battery and allow the device to cool with the battery compartment
open for at least 5 minutes.
If this error message occurs frequently, it suggests that the device is operating in an
extreme performance setup (consider increasing the resistance [Ω] of the coil used and/or
reducing the device's power [W]).