RIB SUPER 2200 Manual
RIB SUPER 2200 Manual

RIB SUPER 2200 Manual

With l1-crx
Hide thumbs Also See for SUPER 2200:

Advertisement

Quick Links

SUPER 2200
L1-CRX
‫ / مع‬with
SUPER 2200 FCE
See page 17
‫رسومات فنية للمشروعات‬
Technical drawings for projects
SUPER 2200 FCM
‫عامل‬
‫مزود الطاقة‬
‫ماكس بوابة الوزن‬
‫ماكس التوجه‬
‫االنفعال االقصى‬
‫الشفرة‬
Operator
Power Supply
Max gate weight
Max Thrust
Max torque
Code
SUPER 2200 FCE
AA31004
230 V 50/60 Hz
2200 kg / 4850 lbs
106Kg / 233lbs
32/30 Nm
SUPER 2200 FCM
AA31008
3 ‫ / الصفحة العربية‬ENGLISH page 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUPER 2200 and is the answer not in the manual?

Questions and answers

Summary of Contents for RIB SUPER 2200

  • Page 1 SUPER 2200 L1-CRX ‫ / مع‬with SUPER 2200 FCE See page 17 ‫رسومات فنية للمشروعات‬ Technical drawings for projects SUPER 2200 FCM ‫عامل‬ ‫مزود الطاقة‬ ‫ماكس بوابة الوزن‬ ‫ماكس التوجه‬ ‫االنفعال االقصى‬ ‫الشفرة‬ Operator Power Supply Max gate weight Max Thrust...
  • Page 2 ‫ الحد األدنى و‬sqmm 1،5 ‫ مع‬H05RN -F ‫ برقية نوع‬RIB ‫2 ° - لل قسم ونوع من النصائح الستخدام الكابالت‬ 3° - Positioning of a possible couple of photoelectric cells: the radius of the photoelectric cells .‫...
  • Page 3 SUPER 2200 FCM ‫2: تركيب وضبط كامات اإليقاف‬ ‫من أجل التمكن من فتح البوابة يدويا من الضروري فتح الكارتير بالمفتاح الصحيح، ثم إدخال مفتاح‬ .‫ في برغي الفتح وإدارته 3 مرات بعكس اتجاه عقارب الساعة‬RIB )‫آلين (مفتاح مسدس األضالع‬ .‫ضع الكامات عىل أط ر اف الرف‬...
  • Page 4 . ‫أ ) ضع البوا بة يف منتصف الطر يق‬ ‫ عىل‬D I P 9 -10 -11 -12-14-15 ‫ ( إ يقا ف ) و‬OF F ‫ عىل‬SUPER 2200 DI P 1- 2- 3- 4 -5-6 -7-8-1 3- 16 ‫ب ) اضبط ا ملفا تيح الد قيقة للطرا ز‬...
  • Page 5 The sump with the appropriate key must be opened. Position the cams at the ends of the Insert the RIB hex key in the release screw and turn it 3 times anti-clockwise. rack rail. To restore the electric functioning, operate in the opposite direction.
  • Page 6 IMPORTANT: The system must comply with all the standards and Directives currently in force. ATTENTION: Install the APP card (or the APP+ card with its modules) and use your smartphone with the RIB GATE App to take advantage of all the advanced features that the...
  • Page 7: System Layout

    SYSTEM LAY-OUT A - SUPER 2200 operator B - Photoelectric cells (external) C - Rack M4 D - Key selector E - Tuned aerial F - Flashing lamp H - Galvanized column for P.E. cells I - Photo electric cells (internal)
  • Page 8 INSTALLATION SUPER 2200 CHECKING BEFORE THE INSTALLATION !! THE GATE SHALL MOVE FRICTIONLESS !! N.B.: Gate features must be uniformed with the standards and laws in force. The door/gate can be automated only if it is in a good condition and its conditions comply with the EN 12604 norm.
  • Page 9: Maintenance

    Measurements in mm/inch Measurements in mm/inch LIMIT SWITCH ADJUSTMENT SUPER 2200 FCE To adjust the assembly: release nuts G, after establishing the direction of movement of cam H for opening and closing, position the two limit switches, F, by turning knobs P and judging by sight.
  • Page 10: Electric Connections

    ELECTRIC CONNECTIONS code AC08082 COMMON Interactive online manuals STOP PHOTOCELL 1 PHOTOCELL 2 EDGE 1 EDGE 2 COMMON LIMIT SWITCH LIMIT SWITCH COMMON TIMER PEDESTRIAN SINGLE COMMAND CLOSE OPEN COMMON 24Vdc 0,4A ±15% A+TEST / A- PHOTOCELLS 24Vdc 0,4A ±15% AUTO-TEST 700 W MAX R=2,2K 1/4W...
  • Page 11 SERIAL COM / Connector for serial connection SYNC RADIO Connector for radio module ACG8069 RADIO Connector for radio receiver RIB, 24 Vdc supply 433 MHz Radio antenna PROG. Programming button Trimmer for automatic closing time adjustment (DISABLED DEFAULT AND DL11 LED OFF)
  • Page 12 DIP 15 DIP 16 MOTOR TYPE automatically the motor warming (code ACG4665). SUPER 2200 POINT C - TIMES PROGRAMMING N.B .: During the programming the safety functions Coast, Photocells, Stop button and Impact TORQUE TRIMMER - Electronic regulator for motor torque detection are active and their performance level is pl “b”...
  • Page 13 SUN 4CH 4-channel - blue keys and white led cod. ACG6054 1 - Set DIP 1 to ON and then DIP 3 to ON. SUN CLONE 2CH 2-channel - blue keys and yellow led cod. ACG6056 2 - LED DL12 flashes green 6 times if the memory is full (1000 codes). LED DL12 blinks red for 10 SUN CLONE 4CH 4-channel - blue keys and yellow led cod.
  • Page 14: Visual And Sound Alarms

    reopens. DL1. The radio commands and the automatic closing will be excluded, since their use in this mode PEDESTRIAN OPEN BUTTON (COM A+/PED.) is not allowed by the norms. Partial opening and closing control. Once the failing safety device is repaired, in automatic after 1 second, all standard commands During pedestrian opening, pausing or closing, you can control the opening of any command functioning again so radio commands and the automatic closing will be enabled again.
  • Page 15: Troubleshooting

    TROUBLE SHOOTING - All the inputs must be used as clean contacts because the power supply is generated internally (safe voltage) in the card and it is set in a way to guarantee the use of the double After having carried out all connections, by carefully following the layout and having positioned insulation and reinforced in relation to parts with hazardous voltage.
  • Page 16 TABLE SUMMARISING VISUAL AND SOUND ALARMS SIGNALS DURING PROGRAMMING SEQUENCE EVENT BUZZER STATUS FLASHER STATUS DL1 LED STATUS DIP 1 ON (hold-to-run mode) Flashes ON/OFF 250 ms Or failure of a safety device DIP 2 ON (full stroke programming) Flashes ON/OFF 500 ms DIP 2 ON >...
  • Page 17 ACCESSORIES - For the connections and the technical data of the optional equipments follow the relevant handbooks. RADIO TRANSMITTER SUN RADIO MODULE 433MHz code ACG8069 SUN 2CH cod. ACG6052 SUN 4CH cod. ACG6054 SUN CLONE 2CH cod. ACG6056 SUN CLONE 4CH cod.
  • Page 18 PHOTOCELLS CONNECTIONS 4 FIT SLIM / FIT SYNCRO photocells with self-test and infrared signal synchronizer 2 photocells FIT SLIM, FIT SYNCRO with self-test COM A+ COM A+ TX SYNCRO A+ TEST PHOT1 PHOT2 A+ TEST PHOT1 PHOT2 cod. ACG8028 cod. ACG8029 A*D+ A*D+ A*D+...
  • Page 19 Pressacavo nichelato 1/4” CME9400 Carcassina AC08082 Scheda L1 CEL1074 Pressacavo PG16 CMO1181 Statore SUPER 2200 230 V~ 50/60 Hz 1P ACG1080 Chiave per serratura carter CEL1129 Mors. mamm. 2 P.431/2LP CMO1314 Rotore con albero SUPER 2200 vent. ACG8103 Piastra da interrare...
  • Page 20: Made In Italy

    Declaration of incorporation for partly completed machinery - Machinery Directive 2006/42/EC, Annex II., B R.I.B. S.r.l. - Via Matteotti, 162 - 25014 Castenedolo - Brescia - Italy Tel. ++39.030.2135811 - www.ribind.it - ribind@ribind.it SUPER 2200 :‫موديل الجهاز‬ :‫الغرض من اإلقرار‬...

This manual is also suitable for:

Super 2200 fceSuper 2200 fcmAa31004Aa31008

Table of Contents