Pentair EVERPURE CONSERV 75E Installation, Operation, Maintenance Manual
Pentair EVERPURE CONSERV 75E Installation, Operation, Maintenance Manual

Pentair EVERPURE CONSERV 75E Installation, Operation, Maintenance Manual

High efficiency reverse osmosis (ro) system

Advertisement

Quick Links

CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS (RO) SYSTEM
INSTALLATION, OPERATION & MAINTENANCE GUIDE
CONSERV 75E
EV9977-00 (US Market)
EV9977-01 (European Market)
EV9977-02 (British Market)
EV9977-03 (Australian Market)
INTRODUCTION
The Everpure Conserv 75E system is a pre-engineered, pre-assembled solution that delivers quality water for non-steam applications. This
all-in-one water treatment system helps minimize sediment, corrosion,* and scale* by reducing TDS, chlorine* and chloramines*.
INSPECTION
Before mounting the Conserv 75E system, inspect the parts. Use the table and illustration provided to verify the parts and quantities
provided. If any parts are missing, contact Customer Service at 800.942.1153 (US only), 630.307.3000 or CSeverpure@pentair.com.
2
1
*Not performance tested or certified by NSF.
PENTAIR® EVERPURE® CONSERV 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE
ORIGINAL INSTRUCTIONS
4
5
8
3
Conserv 75E
9
6
7
Parts
1. Back panel assembly
2. Cover
3. Support leg
4. GRO-75EN RO membrane cartridge
5. 4CC mineral cartridge
6. 4FC5-S filter cartridge
7. 4CB5 filter cartridge
8. Power cord
9. Blue, white and red tubing

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVERPURE CONSERV 75E and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair EVERPURE CONSERV 75E

  • Page 1 EV9977-03 (Australian Market) Conserv 75E INTRODUCTION The Everpure Conserv 75E system is a pre-engineered, pre-assembled solution that delivers quality water for non-steam applications. This all-in-one water treatment system helps minimize sediment, corrosion,* and scale* by reducing TDS, chlorine* and chloramines*. INSPECTION Before mounting the Conserv 75E system, inspect the parts.
  • Page 2: Tools Required

    Total Dissolved Solids: 1,000 ppm maximum Sulfide, Iron and Manganese: Less than 0.1 ppm Water Supply pH Limits: 4 to 11 Turbidity: 1.0 NTU maximum 2 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 3: Safety Instructions

    Do not use electrical heating tape or propane torch on this unit. PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 3...
  • Page 4: Installation Illustrations

    Note: Feet may be removed. 1/4" Tubing to Supply Water In Drain 3/8" Tubing 3. Install Pentair GRO-75EN RO membrane cartridge White GRO-75EN Blue 4 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 5 Closed Remove Plug Insert 3/8" Tubing Power Off Remove 3/8" Tubing Replace Plug Insert 3/8" Tube Closed Closed Open Flush for Five (5) Minutes PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 5...
  • Page 6 When pump stops, open for five (5) minutes. Repeat four (4) times NOTE: During the final flush, the storage tank and the 4CC mineral cartridge are flushed. 6 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 7 TDS meter (not included) No adjustment Repeat steps one needed and two until TDS is at adjustments are target no longer needed 2" Blending Valve PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 7...
  • Page 8: Installation

    CLOSE the inlet and outlet valves on the RO system. Reapply pressure to the plumbing by slowly OPENING the shut-off valve that was closed in the previous step. 8 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 9: Installing The Cartridges

    RO filter. Remove Cover Screw F. Insert RO water connection into the blue quick-connect port 4CB5 of the RO filter. 4FC5-S GRO-75EN Figure 4 PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 9...
  • Page 10: Storage Tank

    F. Flush the cartridge for five (5) minutes. Then CLOSE the incoming water shut-off valve. G. Remove the temporary tubing from the flush port. Reinsert the plug that was removed in Step 3. 10 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 11: Testing Your Reverse Osmosis System

    Under NSF/ANSI Standard 58, it is highly recommended that the blended water be tested at least every six (6) months to verify that the system is performing satisfactorily. PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 11...
  • Page 12: Changing The Cartridges

    OPEN the delivery faucet and flush the system for about 10 minutes, NOTE: If a drip pan is used, clean with dish soap and warm water. then follow the filter cartridge replacement instructions below. 12 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 13 Make a length of tubing with angle quick- connectors. Use the length of tubing with two right-angled quick-connectors to connect the white tubing at the top to the PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 13...
  • Page 14: Troubleshooting

    2. Otherwise, draw 1 gal (3.8 L) of water from the unit. After 10 minutes, run water from the blended water port and test the water again. 3. Determine when you last changed the RO cartridge and call Technical Support. 14 • PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE...
  • Page 15: Replacement Parts

    Waste water restrictor EV3114-07 4CB5 filter cartridge Conserv 75E cartridge kit 151120 Storage tank AS/NZS 3497 WM-40252 TDS meter GlobalMark.com.au Water Treatment Appliance - E359339 PENTAIR® EVERPURE® CONSERV® 75E HIGH EFFICIENCY REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION & MAINTENANCE GUIDE • 15...
  • Page 16 Southeast Asia | 390 Havelock Road, | #04-01 King’s Centre | Singapore 169662 | 65.6768.5800 Tel | cseverpure@pentair.com All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners ©2023 Pentair.

This manual is also suitable for:

Ev9977-00Ev9977-01Ev9977-02Ev9977-03

Table of Contents