List of Components ■ Main Unit Item Model Function High Temperature Multi-Channel Measurement start and stop Anemomaster PRO main unit 1595-0G Measurement value display Data management Software download site Information on download sites for software, information instruction manuals, etc. USB cable Connecting units 1580-1G AC adapter (90W)
Page 4
■ Probe Item Model Function Medium temperature probe 0213-00 Digital output of air velocity values High Temperature Probe 0214-00 Digital output of air velocity values High Temperature Probe 0215-00 Digital output of air velocity values ■ Options Item Model Function 0.5m 1580-30 1580-31...
Important Safety Information The symbols for the warnings used in this manual are defined below: Description of Symbols Warning Warnings in this classification indicate risks that may result in serious injury or death if not observed. Caution Warnings in this classification indicate risks that may result in injury or damage to the surrounding objects if not observed.
Page 6
Failure to observe the above may cause electric shock, fire, and/or damage. Please contact your local distributor or Kanomax service center for repair. Caution (Proper Handling) Pull out the plug when the instrument is not in use.
Page 7
(Forbidden)This instrument is designed to be used in the clean air flow without dusts and/or foreign substances. Touching or hitting the air velocity sensor with a foreign substance may cause damage to the sensor. Dust and/or foreign substances adhered to the air velocity sensor can hinder accurate measurement.
Page 8
(Forbidden)When disposing of the product, do not throw it together with general garbage. Always follow all applicable laws when disposing of this unit and AC adaptor. or contact your sales agent. ( Forbidden ) Turn off the power when connecting or disconnecting the connector.
Table of Contents List of Components ..........................i Important Safety Information ......................iii Table of Contents ..........................vii 1. Part Names and Functions ....................... 9 Main Unit(Model 1595-0G) ......................9 High Temperature Hub Unit(Model 1593-0G) ................10 Analog Unit(Model 1592-0G) .......................
Screen transition diagram........................43 High Temperature Hub Unit ........................44 Connection ............................. 44 Power ON/OFF ............................46 LED display ............................. 46 Analog Unit ..............................47 Connection ............................. 47 Power ON/OFF ............................49 LED display ............................. 49 Probe ................................50 Connection ............................. 50 Power ON/OFF ............................
1. Part Names and Functions 1. Main Unit(Model 1595-0G) ① ② ③ ④ ⑧ ⑤ ⑥ ⑦ ⑨ ⑪ ⑫ ⑩ Name Function ① LED (Blue/Red) Displays the status of this unit ② LAN terminal Communicates with the PC via Ethernet ③...
2. High Temperature Hub Unit(Model 1593-0G) ① ② ⑤ ③ ④ ⑧ ⑥ ⑦ Name Function ① LED (Blue/Red) Displays the status of this unit ② Probe-to-probe Communicates with another probe communication terminal (1 to 6 CH) ③ Unit-to unit communication Communicates with another unit terminal (UP/DOWN) ④...
3. Analog Unit(Model 1592-0G) ① ② ⑤ ⑥ ⑦ ⑧ Name Function ① LED (Blue/Red) Displays the status of this unit Outputs analog values to have been set in the main unit. ② Analog output terminal Connects to CH to be used in the dividing (1 to 12 CH) terminal block (accessory), and wire to the output.
2. Getting Ready to Measure System configuration This system uses multiple units, cables and power supply devices combined as shown below. This chapter explains how to configure them to get ready to measurements. ・Main Unit Displays measured values, starts/stops measurements, and sets measurement settings. At least one main unit has to be used.
Wrong connections can cause malfunction and/or damage. Prior to turn the power ON, read this User’s Manual carefully, configure each instrument in the following sequence. Do not connect or disconnect the probe or connector while the power is supplied. 1. Connect the unit 2....
Page 16
If you use the clip (optionally available), you can fix the units to connect. As the below figure shows, insert the clip into the insertion port of adjacent units to connect. To disconnect the connected units, remove this clip first and disconnect. To disconnect the connected units, put your fingers in the hand well at the bottom face of the units, and pull the units outward.
Page 17
You can also remove the connected units by inserting the stylus (main unit accessory) into the indentation of the side of the units as far as it will go. Indentation Stylus 2. Connecting using a standard cable The main unit is equipped with the DOWN connecting connector, and the High temperature hub/analog units are equipped with the UP connecting connector and the DOWN connecting connector respectively.
Page 18
To disconnect the standard cable (optionally available), as the below figure shows, push and hold the release buttons, and remove the cable from the connector. 2. Getting Ready to Measure...
Page 19
How to connect the units by the above two methods, refer to the below. Situate the main unit in the first row. When connecting another unit, situate another unit to the next of the first unit. When connecting another unit again, connect the unit to the last connected unit.
Page 20
Do not connect the units as the following figure shows. With this connection, conducting accurate measurement is impossible. ※1 When adding another unit, using the standard cable, connect the communication terminal DOWN of the rearmost situated unit in the front block to the foremost situated unit in the rear block.
Connecting the power source The device is powered using the AC adapter (90W: main unit accessory, 160W: optionally available item) or the DC power connection cable (optionally available). Do not use any AC adapters or cables other than those specified. Failure to do so will result in failure or damage.
Page 22
When the units are connected with the standard cable, power in each unit is not connecting each other. Therefore, power should be supplied to each unit. When the connected-unit block is linked to another block with the standard cable, as the ...
Page 23
The below list shows the number of connected unit capable to operate with the AC adapter. Power supply 90W AC adapter 160W AC adapter The maximum number of Main unit 1 EA, Main unit 1 EA, connected unit High temperature hub unit 1 High temperature hub unit 2 EA, and Analog unit 1 EA EA, and Analog unit 2 EA...
Page 24
The orientations should be matched. Supplying power using the DC power connection cable (optionally available) Power can be supplied using the DC power connection cable (optionally available) if you don't use the AC adapter. However, the DC power cable sold separately is needed to be prepared by a user. (DC power: 12 to 24 V) Each unit must be used not more than the total power as below and not more than a current of 6A.
Page 25
Number of hub unit/analog unit connections and sampling rate Measuring at a high sampling rate when using multiple hubs and analog units requires extremely high processing power. To ensure stable measurements, please use within the ranges in the table below. Number of hub Sampling interval Minimum connections...
Connecting the probe For the probe-to-high temperature hub unit connection, connect the probe connector (CH1 to CH6) of the high temperature hub unit and the connector of the probe converter box with the high temperature standard cable (optionally available). High temperature standard cable (Optionally available) Probe converter box...
Trigger input connection Please use a φ2.5 audio plug for the trigger input terminal. φ2.5 audio plug Circuit The trigger input terminal is a non-voltage contact input. For connection, use a switch, relay, open collector output, or open drain output. Switch Relay Open collector...
Connecting the analog unit As to connection between the analog unit and the output, connect the dividing terminal block (accessory) to the analog unit, and wire to the output. Be sure to turn off the power to the analog unit during this step. Otherwise, malfunction and/or damage may occur. As to the pin layout of each CH on the analog output terminal, refer to the figure below.
Page 29
To wire the dividing terminal block, refer to the photos below. The allowed range of wires to use for wiring: Stranded wire (element wire: φ0.18 mm or thicker): 0.2 ㎟ to 1.25 ㎟ (AWG24 to AWG16: 9 mm length of stripped wire) Solid wire: φ0.4 mm to φ1.2mm (AWG26 to AWG16: 9 mm length of stripped wire) Pull the white...
3. Overall Flow Measurement Turn the power on, and set and save each parameter on the measurement setup screen displayed. The order in which you power on the HUB unit and analog unit does not matter, but make sure to power on the main unit last.
4. User Interface Main Unit Connection Name How to connect Connect this terminal to the LAN network that is the same LAN terminal one with the PC to be connected using a LAN cable. Connect this terminal to the PC to be connected using the USB terminal USB cable supplied with the main unit or a USB cable 2.0 (for PC)
Connect this connector (socket) to the connecting connector (plug) of another unit. Connecting connector If the unit-to-unit communication terminal has already (Socket) been used to connect to another unit, do not use this connector. Power ON/OFF To turn the power ON/OFF, use the power switch on the side of the unit. Prior to using the power switch, make sure that the AC adapter (90W/160W) is connected to the main unit, or to the connected units using the connecting connector.
Page 33
Title screen When the power switch is turned on, the title screen appears. After a short period of time, the screen changes to the measurement setup screen automatically. 4. User Interface...
⑥ ⑧ ⑩ ④ ⑤ ⑦ ⑨ Name Function ① Logo KANOMAX Logo is displayed. ② Unit name Indicates the measurement unit name. ③ Date/time Indicates date and time Measure setting Displays the measurement setup screen for various ④ button...
Measurement setup screen The measurement setup screen appears when starting the main unit or tapping the Measure setting button. On this screen, check/change various settings on measurement. Checking/changing the settings are not allowed during measurement. ⑬ ① ② ③ ④ ⑤...
Page 36
Save ⑪ measurement Set to save data after measurement automatically or not. data Remaining Displays the memory remaining capacity to save measurement ⑫ capacity data. Remaining time Select [remaining time] or [elapsed time] as the display of ⑬ display measurement time. ⑭...
Measurement screen Tap the Measure button to display the measurement screen. On this screen, set various display of measured values and select the measurement start/stop. ① ② ③ ④ ⑥ ⑤ 4. User Interface...
Page 38
Item Description Select the hub unit(s) to display measurement values. You ① Hub control can select up to 12 units. Switch the measured value display between ON/OFF by channel. ② Channel button (ON) (OFF) Switch the use of external trigger between ON/OFF. External trigger ③...
Graph screen Tap the Graph button to display the graph screen. On this screen, display measured values in graph form. ④ ① ⑧ ② ⑥ ⑦ ⑤ ③ Item Description Select the hub unit to display data in graph form. You can ①...
File screen Tap the File button to display the file screen. On this screen, you can rename the saved measured data, copy data to a USB memory, transfer data, and delete data. Those operations are not allowed during measurement. ⑦ ②...
Configuration screen Tap the Sys. setting button to display the configuration screen. On this screen, check/change the main unit settings. Changing/saving the settings are not allowed during measurement. ① ⑤ ② ③ ④ ⑨ ⑧ ⑦ ⑥ Item Description ① Time setting Set date/time for the internal clock.
Connect screen Tap the Connect button to display the connect screen. On this screen, you can check the connection status of each connected probe, product No. and serial No. ① ② Item Description Select the hub unit(s) to display data in graph form. You can ①...
Analog setup screen Tap the AN Setting button to display the analog setup screen. On this screen, you can select measured values of the probe outputting to the output CH of the analog unit. Checking/changing the settings are not allowed during measurement. ⑦...
Page 44
This shows the range relations among air velocity, current output and voltage output. Current Voltage Air velocity output output Connected probe range range range [m/s] [mA] 0213-00/0214-00/0215-00 0~50.0 4~20 0~5 Example: Probe 0213-00 and air velocity 20 m/s This shows the range relations among temperatures, current output and voltage output. Current Voltage Temperature...
interval is set to a short value, a delay may occur in the analog output. For details, see the section "Connecting Units" in this chapter. Screen transition diagram The screen consists of a three-level hierarchy. Operations on second level or less are mainly used.
High Temperature Hub Unit Connection Name How to connect Connect this terminal to the probe converter box of the probe to be connected using the high temperature Probe-to-probe standard cable (optionally available). communication terminal The available standard cable (optionally available) can (1 to 6 CH) be selected from 0.5 m, 2.0 m, 5.0 m, 10.0 m, 20.0 m and 40.0 m.
Page 47
Using the standard cable (optionally available), connect this terminal (DOWN) to the unit-to-unit communication terminal (UP) of the unit to be connected. For details, refer to 2. Getting Ready to Measure > Connecting the units. DOWN The available standard cable (optionally available) can be selected from 0.5 m, 2.0 m, 5.0 m, 10.0 m, 20.0 m and 40.0 m.
Power ON/OFF To turn the power ON/OFF, use the power switch on the side of the unit. Prior to using the power switch, make sure that the AC adapter (90W/160W) is connected to the main unit, or to the connected units using the connecting connector. Otherwise, malfunction and/or damage may occur.
Analog Unit Connection Name How to connect Using the dividing terminal block (accessory), connect this terminal to a device to be connected such as a Analog output terminal data logger. (1 to 12CH) For details, refer to 2. Getting Ready to Measure > Connecting the units.
Page 50
Using the standard cable (optionally available), connect this terminal unit-to-unit communication terminal (UP) of the unit to be connected. For details, 2. Getting Ready to Measure > Connecting the units. DOWN The available standard cable (optionally available) can be selected from 0.5 m, 2.0 m, 5.0 m, 10.0 m, 20.0 m and 40.0 m.
Power ON/OFF To turn the power ON/OFF, use the power switch on the side of the unit. Prior to using the power switch, make sure that the AC adapter (90W/160W) is connected to the main unit, or to the connected units using the connecting connector. Otherwise, malfunction or damage may occur.
Probe Connection Probe converter box Name How to connect Using the high temperature standard cable (optionally available), connect this terminal to the probe-to-probe communication terminal of the hub unit to be Hub unit-to-hub unit connected. communication terminal available high temperature standard cable (optionally available) can be selected from 0.5 m, 2.0 m, 5.0 m, 10.0 m, 20.0 m and 40.0 m.
Turn off the power, and turn on the power again. Error occurred in the built-in If LED (red) is still ON, please CPU. contact your distributor KANOMAX service center. Check adapter Flashing Power voltage is decreasing. (90W/160W) connected to the (Red) hub unit.
Probe Cleaning Dust such as fine/soot particles or machine oil adhered to the air flow element can change the heat dissipation (the amount of heat taken away). This can affect the reading of air velocity. Probes with a wire mesh or a filter cannot read an accurate measurement value when they are clogged with substances as dust.
5. Specifications ■ Main Unit Product name High Temperature Multi-Channel Anemomaster PRO main unit Model 1595-0G Display, Operation 7.0 inch color LCD with touch panel High temperature Multi-Channel Anemomaster PRO hub unit Connectable unit (Model 1593-0G) Multi-Channel Anemomaster PRO analog unit (Model 1592-0G) Data Communication function Communication...
Page 56
■ Hige Temperature Hub Unit Product name High Temperature Multi-Channel Anemomaster PRO hub unit Model 1593-0G High temperature Multi-Channel Anemomaster PRO main unit (Model 1595-0G) Connectable unit High temperature Multi-Channel Anemomaster PRO hub unit (Model 1593-0G) Multi-Channel Anemomaster PRO analog unit (Model 1592-0G) Model 0213-00: Medium Temperature Probe Connectable probe Model 0214-00: High Temperature Probe...
Page 57
■ Analog Unit Product name Multi-Channel Anemomaster PRO analog unit Model 1592-0G High temperature Multi-Channel Anemomaster PRO main unit (Model 1595-0G) High temperature Multi-Channel Anemomaster PRO hub Connectable unit unit (Model 1593-0G) Multi-Channel Anemomaster PRO analog unit (Model 1592-0G) Communication Unit-to-unit Serial communication (Standard cable) function...
Page 58
■ Probe For all probes, warranty period is one year from date of purchase. ・Probe converter box Operating environment 0 to 60℃, 5 to 95%RH with no condensation Storage environment -10 to 60℃, 0 to 90%RH with no condensation Dimensions W90mm ×...
Page 59
・Probe 0213-00 0214-00/0215-00 Model V0~50.0m/s V0~50.0m/s Velocity Velocity V0=0.2m/s:0~99℃ V0=0.2m/s:0~99℃ Measurement V0=0.4m/s:100~200℃ V0=0.4m/s:100~199℃ range Velocity V0=0.7m/s:200~299℃ V0=1.0m/s:300~400℃ Measurement range 0~200℃ 0~500℃ Temperature Display resolution Measurement range accuracy V0~4.99m/s ±0.15m/s 5.00~9.99m/s ±0.30m/s 0.01m/s Velocity 10.0~24.9m/s ±0.75m/s Measurement accuracy 25.0~50.0m/s ±1.50m/s 0~99.9℃ Temper 100~199℃...
Page 60
※ Model 0972-00/0973-00 probe is directional. Be sure to aim the direction mark at windward. Wind If you are not able to find a correct airflow direction, slowly rotate the probe and select a direction where you have a maximum velocity reading, and perform a measurement.
Page 61
■ Standard Cable Model 1580-30 1580-31 1580-32 1580-33 1580-34 1580-35 0.5 m 2.0 m 5.0 m 10.0 m 20.0 m 40.0 m Length ± tolerances +0.05,-0 +0.1,-0 +0.2,-0 +0.3,-0 +0.5,-0 +1.0,-0 Operating 0 to 60℃, 5 to 95%RH with no condensation environment Storage environment -10 to 60℃, 0 to 95%RH with no condensation...
7. Warranty and After-Sales Service The limited warranty set below is given by KANOMAX JAPAN, Inc. (hereafter referred to as “KJI”) with respect to this instrument, its attachment parts including standard accessories (hereafter referred to as “PRODUCT”) that you have purchased. PRODUCT you have purchased shall be the only one that the limited warranty stated herein applies to.
You are responsible for all return shipping charges to the authorized KANOMAX service center. This limited warranty covers all defects encountered in normal use of the PRODUCT, and does not apply...