Download Print this page

Advertisement

Quick Links

Reach Anchor Manual
ANSI
Z359.18-2017 Type A
OSHA 1926.502, 1910.140, 1910.66
024-4109
Reach Anchor Assembly
022-4086
023-4107
024-4110
Magnetic Quick Connector Base
024-4111
V2. 2024 Copyright Safewaze: 220-00079
Reach Anchor
Reach Anchor Pole
Reach Anchor:
Reach Anchor:
Hook Attachment

Advertisement

loading
Need help?

Need help?

Do you have a question about the 022-4086 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SafeWaze 022-4086

  • Page 1 Reach Anchor Manual ANSI Z359.18-2017 Type A OSHA 1926.502, 1910.140, 1910.66 024-4109 Reach Anchor Assembly 022-4086 Reach Anchor 023-4107 Reach Anchor Pole Reach Anchor: 024-4110 Magnetic Quick Connector Base Reach Anchor: 024-4111 Hook Attachment V2. 2024 Copyright Safewaze: 220-00079...
  • Page 2: User Information

    Read and understand instructions before using equipment! Do not throw away instructions! Always verify the latest revision of the Safewaze Manual is being utilized. Visit the Safewaze website, or contact Customer Service, for updated manuals. IMPORTANT: • Please refer to this manual for essential instructions on the use, care, or suitability of this equipment for your application.
  • Page 3 Women who are pregnant and individuals considered minors must not use any Safewaze equipment. • Do not alter or misuse equipment. Only Safewaze, or entities authorized in writing by Safewaze, may make repairs to Safewaze fall protection equipment.
  • Page 4: Table Of Contents

    Compatibility of Connectors ► ► 11.0 Making Connections ► ► 12.0 Installation / Operation of Reach Anchor ► ► 13.0 Inspection / Maintenance ► ► 14.0 Labels ► ► 15.0 Annual Inspection Form ► ► V2. 2024 Copyright Safewaze: 220-00079...
  • Page 5: Introduction

    Safewaze. Use of this equipment in a manner outside the scope of those covered within this manual can result in serious injury or death. The equipment covered in this manual must only be used by trained personnel in workplace applications.
  • Page 6: Rescue Plan

    (2267.9 kg) per user attached. Or, anchorages for attachment should be designed, installed, and used as part of a complete PFAS which maintains a safety factor of at least two and is under the supervision of a Qualified Person. V2. 2024 Copyright Safewaze: 220-00079...
  • Page 7: Allowed Anchorage Applications

    Do not allow the lifeline to pass under arms or between the legs. • Sharp Edges: Safewaze Class 1 SRLs are NOT designed for use in Leading Edge Environments. Should a specific work area have an extremely sharp edge/ edges that may come into contact with the lifeline constituent of the SRL, a Class 2 SRL is required.
  • Page 8: Product Specifications

    Work Positioning: Safewaze Anchors are authorized for use in Work Positioning applications. Work Positioning allows a worker to be supported during suspension while freeing both hands to conduct work operations. The structure to which the Anchor is attached must withstand loads applied in the directions permitted by the system of at least 3,000 lbs.
  • Page 9 Note: Numbers used in these examples are based on ZERO offset and setback with the anchor directly overhead or below, to represent an in-line Fall Clearance calculation. Consult with a Competent Person when working in different scenarios and when using non-Safewaze equipment. 6' FREE FALL LANYARD (OVERHEAD) EXAMPLE...
  • Page 10: Compatibility Of Connectors

    ► ► 10.0 COMPATIBILITY OF CONNECTORS • Safewaze equipment is designed for, and tested with, associated Safewaze components or systems. If substitutions or replacements are made, ensure all components meet the applicable ANSI requirements. Read and follow manufacturer’s instructions for all components and subsystems in your PFAS. Not following this guidance may jeopardize compatibility of equipment and possibly affect the safety and reliability of the system.
  • Page 11: Making Connections

    Ensure all connectors are fully closed and locked. Safewaze connectors (hooks, carabiners, and D-rings) are designed to be used only as specified in each product’s manual. See Figure 3 for examples of inappropriate connections.
  • Page 12: Installation / Operation Of Reach Anchor

    Cord with the Hook Head attachment. Lower the black Shuttle to the ground. 14. Use the Hook Head of the Pole to pull the Locking Switch located on the Clamp Assembly into a downwards position. V2. 2024 Copyright Safewaze: 220-00079...
  • Page 13 Do not reposition the Reach Anchor by dragging its extension arms along the I-beam, pipe, and/or other pre-established anchor points. Anchor Point Floor Locking Switch in "up" position V2. 2024 Copyright Safewaze: 220-00079...
  • Page 14 Flip Lever unlocked Flip Levers locked DO NOT put carabiner through Pull Cord V2. 2024 Copyright Safewaze: 220-00079...
  • Page 15 Remove Hook Head through Pull Cord Install Locking Switch in "down" position V2. 2024 Copyright Safewaze: 220-00079...
  • Page 16: Inspection / Maintenance

    Hook Head. Repairs/Disposal: • Only Safewaze, or entities authorized in writing by Safewaze, may make repairs to Safewaze fall protection equipment. Dispose of the anchor if inspection reveals an unsafe or defective condition. If damaged and unserviceable, the system should be destroyed so as not to allow accidental re-use.
  • Page 17 IMAGE 1: COMPONENT INSPECTION Clamp Assembly Extension Arm(s) Locking Switch Pole Mount Shuttle Housing Label Pack D-Ring Pull Cord Tagline Shuttle Pole Magnet Head Hook Head Flip Lever(s) Pole Extension Label V2. 2024 Copyright Safewaze: 220-00079...
  • Page 18: Labels

    INITIAL DO NOT ATTEMPT TO SERVICE OR REPAIR THIS UNIT! CONTACT SAFEWAZE FOR SERVICE OR REPAIR INFORMATION. Device must be inspected prior to each use in accordance with the manufacturer’s instructions. Inspect the device for label legibility, any evidence of damage or defects, and missing components or parts.
  • Page 19: Annual Inspection Form

    ANNUAL INSPECTION FORM Inspection Inspector: Pass/Fail: Comments/ Date: Corrective Action: V2. 2024 Copyright Safewaze: 220-00079...
  • Page 20 Address: 225 Wilshire Ave SW, Concord, NC 28025 Phone: (800) 230-0319 Fax: 704-262-9051 Email: info@safewaze.com Website: safewaze.com V2. 2024 Copyright Safewaze: 220-00079...

This manual is also suitable for:

024-4109023-4107024-4110024-4111