  • Page 1 D5233Q INSTRUCTION MANUAL SIL2 Switch/Proximity Transistor-Out Repeater DIN-Rail and Termination Board, Model D5233Q D5233- SIL2 Switch/Proximity Transistor-Out Repeater G.M. International ISM0660-0...
  • Page 2: Technical Data

    Characteristics General Description: The Switch/Proximity Detector Repeater D5233 is a module suitable for applications requiring SIL 2 level in safety related systems for high risk industries. The unit can be configured for switches or proximity detectors, located in Hazardous Area, and repeats the input state to an open-collector transistor in Safe Area. The selectable fault detection circuit is available for proximity sensors or switches equipped with end-of-line resistors.
  • Page 3: Ordering Information

    Ordering Information Power Bus and DIN-Rail accessories: Model: D5233 Connector JDFT050 Bus Mounting Kit OPT5096 4 channels Front Panel and Features SIL 2 / SC 3 (pending) Input from Zone 0/Div. 1 Installation in Zone 2/Div. 2 CONFIG High frequency transistor output Field open and short circuit detection STS/FLT Input inversion available...
  • Page 4 Parameters Table In the system safety analysis, always check the Hazardous Area/Hazardous Locations devices to conform with the related system documentation, if the device is Intrinsically Safe check its suitability for the Hazardous Area/Hazardous Locations and group encountered and that its maximum allowable voltage, current, power (Ui/Vmax, Ii/Imax, Pi/Pi) are not exceeded by the safety parameters (Uo/Voc, Io/Isc, Po/Po) of the D5233 series Associated Apparatus connected to it.
  • Page 5: Function Diagram

    In 1 Out 2 In 2 Out 3 Out 4 In 3 In 4 Supply BUS Connector Connector D5233Q used as double channel with Duplicator or Fault Output Configurator Voltage Free Voltage Free Contact Contact Proximity In 1 Out 1...
  • Page 6 Any unauthorized modification must be avoided. Operation The Switch/Proximity Detector Repeater type D5233Q is a unit with four independent channels suitable for applications requiring SIL 2 level (according to IEC 61508:2010) in safety related systems for high risk industries. The unit can be configured for switch or proximity detector (EN60947-5-6 NAMUR), NO or NC input and for NO or NC floating open collector transistor isolated (opto-coupled) output compatible with logic circuits.