Items included:
Pump
Dual float and controller
Stainless steel hose clamp
2 inch x 1½-inch reducer
adapter (on ¾ HP pump only)
Note:
The ¾ HP pump will accomodate a 2-inch discharge pipe. However, most
homes have 1½-inch pipes. Therefore we have included a 2-inch x 1½-inch reducer
adapter with this pump. You may replace your 1½-inch discharge pipe with a 2-inch
discharge pipe, and a 2-inch adapter to obtain the optimum gallons per hour.
You may also need:
1½-inch or 2 inch rigid PVC pipe to
connect to the existing plumbing
A check valve or union
PVC pipe cleaner and cement
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS
and OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need
to refer to it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
Risk of electric shock. To reduce this risk, observe the
!
WARNING
following precautions.
• ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or
damp surface while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump
is wired with a 3-prong grounded plug. To reduce the risk of electric shock, be
certain that it is only connected to a properly grounded, 3-prong receptacle. If you
have a 2-prong receptacle, have a licensed electrician replace it with a 3-prong
receptacle according to local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length
of the pump's power cord, and at least 4 feet above the floor level to minimize
potential hazards from flood conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
• MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to
handle the power requirements noted on the nameplate of the pump.
To reduce the risk of hazards that can cause injury or
!
CAUTION
property damage, observe the following precautions.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT pull on the float switch cord.
• DO NOT expose the control unit to water, rain or snow.
• DO NOT place the controller on the floor. The electrical outlet should be within the
length of the pump's power cord and at least 4 ft above the floor.
• DO NOT operate the pump or control unit if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous
liquids. This product is rated for ground water use only.
• DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to
the manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
• When installing or replacing a primary sump pump you should also install a
battery backup sump pump system.
Specifications
½ HP Model BWT050
GPH @ 0'
GPH @ 10'
Pump diameter
Volts
115V, 60Hz
Amps
1½-inch
discharge
½ HP Pump
BWT050
¾ HP Model BWT075
4100
5300
2770
3630
7.375"
9.75"
115V, 60Hz
3.8
4.8
2-inch