Instruction Manual &
Safety Warnings

Table of Contents

Instructions
2
2
Battery precautions
2
Items included in system
3
Additional items needed
3
3
4
5
Battery Maintenance
5
5
5
5
5
5
6
Lights and Alarms
6
Power alarm
6
6
7
7
Battery alarm
8
9
9
Testing the System
Testing the pump
9
9
Weep holes
9
10
10
Technical support
11
Replacement Parts Diagram & List 11
12
13
Combination Primary and
Backup Sump Pump System
Model CITE-33
IMPORTANT: Even if you have the Basement Watchdog sump pump system installed
by someone else, you must read and follow the safety information contained in this
manual. Failure to do so could result in property damage, serious injury, or death.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Combo CITE-33 and is the answer not in the manual?

Questions and answers

Summary of Contents for The Basement Watchdog Combo CITE-33

  • Page 1: Table Of Contents

    Connecting the backup pump Technical support Connecting the battery IMPORTANT: Even if you have the Basement Watchdog sump pump system installed Replacement Parts Diagram & List 11 Connecting the charger by someone else, you must read and follow the safety information contained in this...
  • Page 2: Important Safety Warnings And

    DANGER vicinity of the battery. • MAKE SURE THERE IS A PROPERLY manufacturer for any repairs at the following • Use the Basement Watchdog control unit Do not use system to pump flammable or GROUNDED RECEPTACLE AVAILABLE. This address: explosive fluids such as gasoline, fuel oil, for charging a LEAD-ACID battery only.
  • Page 3: Introduction

    Introduction Model CITE-33 The Basement Watchdog combination sump pump system is designed to provide both primary and backup pumping capabilities. The primary pump will operate as long as it is receiving AC power. If the power is Backup interrupted, or more water is coming into...
  • Page 4: Installing The Pipe And Pump

    You should place a pump the sump pit) to the end of the existing The Basement Watchdog combination system the discharge pipe until it is even with stand or bricks on the floor of the sump pit to discharge is 19".
  • Page 5: Battery Instructions

    In addition, the unique materials in shock. Wear eye protection. Work in a well- 1. Mounting the backup control unit: (a) the Basement Watchdog AGM battery enable ventilated area. Do not smoke or allow a Thread one plastic cable tie through the it to last longer in standby service.
  • Page 6: Product Operation 6 Warranty

    While the pumps are active, water will come The Basement Watchdog backup sump pump out of the 3/16" hole that is located on the top During a power outage or times when the...
  • Page 7: Replacing The Backup Pump

    the primary pump has resumed normal hydrogen or oxygen gas that may have pump and primary float switch. Remove 15. Slide the backup pump assembly into the been emitted from the battery. operation and the backup pump is no longer the wye pipe.
  • Page 8 2. Remove the charger plug from the back of as the rubber union is loosened. Now reverse the process. the backup controller. 7. Separate the pump assembly from the 14. Screw in the check valve on the top of 3. Unplug the backup pump from the back rubber union and lift it out of the sump by the new primary pump.
  • Page 9: Cleaning Battery Terminals

    REPLACING THE BATTERY your car battery. 6. Clean any corrosion off of the ring connectors on the ends of the battery Once the AC power is restored, the battery DANGER wires. Us a stiff brush or sandpaper. will recharge automatically, unless it is old or Risk of electrical shock or battery explosion, DO NOT apply corrosion-resisting sprays damaged.
  • Page 10: Testing The Primary Float Switch

    WATER SPRAYING FROM PUMP TESTING THE PRIMARY PUMP MAINTENANCE CHECKLIST FLOAT SWITCH Maintenance should be performed 1-2 times While the pumps are active, water will come per year. out of the 3/16" hole located on the top of It is important to manually test the the main pump and the 3/16"...
  • Page 11: Parts & Service Information

    Replacement Parts List BOTTOM VIEW Description Part No. 1/3 HP AC sump pump SIT-33NS Caged dual float switch with piggyback controller BWC2 Emergency backup pump 1011014 Emergency control unit BWE-CONT Wye PVC pipe fitting with 45° elbow 1120017 Support bracket for backup pump 1121018 Battery cap with hole for the fluid sensor 1125000...
  • Page 12: Troubleshooting Guide

    Primary Pump Troubleshooting Guide Backup Pump Troubleshooting Guide DANGER DANGER Read safety warnings & instructions before attempting any repairs or maintenance. Read safety warnings & instructions before attempting any repairs or maintenance. THE PUMP WILL NOT START OR RUN Potential Cause Solutions BATTERY PROBLEM Potential Cause...
  • Page 13 All parts and labor (excluding installation) for a period of: • 2-year standard warranty; 4 yrs when purchased WITH the Basement Watchdog Battery (BW-27AGM) AND registered online The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace the product and return it postage prepaid.
  • Page 14 Watching Out for You! Scan the QR code to tap into a wealth of knowledge and get the most out of your CITE-33 combination sump pump system. Or visit our vast collection of online resources by typing in this URL directly into your Web browser: www.basementwatchdog.com/support/cite-33-combination-sump-pump-resources/ Installation User Resources...
  • Page 15 Additional Products to Help Protect Your Basement Basement Wash-Dog Maintenance Free Battery Water Alarms Sewage Pump SUMP SYSTEM CLEANER BW-27AGM BW-WA360 SW-50T WDT20 1/2 HP FEATURES AND BENEFITS: ƒ Patented design allows it to detect water on any side ƒ Senses as little as ¹/ ₃₂ " of water ƒ...
  • Page 16 © 2023, Glentronics, Inc. 1806185 08/23...

Table of Contents