The Basement Watchdog CITS-50 Instruction Manual & Safety Warnings

Combination primary and backup sump pump system

Advertisement

Quick Links

Instruction Manual &
Safety Warnings

Table of Contents

Instructions
Electrical precautions
1
Battery preparation
1
1
Introduction
Items included in system
2
Additional items needed
2
2
3
4-5
Mounting the backup control unit
5
5
Installing the battery fluid sensor
5
5
5
6
6
6
Lights and Alarms
6
6
7
7-8
Fuse alarm
8
Water Alarm
8-9
Pump alarm
9
9-10
10
Power alarm
10-11
Charging
11
11
Testing the System
11
11
11
Remote Alarm
11
USB Data Port
11
11
12
Technical support
12
13
Warranty
14
Combination Primary and
Backup Sump Pump System
Model CITS-50
This manual is for the systems that have the BWSP-A backup controller, which can accommodate
wet-cell or maintenance-free batteries. See page 4 for additional information.
IMPORTANT: Even if you have the Basement Watchdog sump pump system installed by
someone else, you must read and follow the safety information contained in this manual.
Failure to do so could result in property damage, serious injury, or death.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CITS-50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for The Basement Watchdog CITS-50

  • Page 1: Table Of Contents

    Product Operation Technical support Understanding the Warning IMPORTANT: Even if you have the Basement Watchdog sump pump system installed by Replacement Parts Diagram & List 12 Lights and Alarms someone else, you must read and follow the safety information contained in this manual.
  • Page 2: Important Safety Warnings And

    RECEPTACLE AVAILABLE. This pump is wired with repairs at the following address: explosive fluids such as gasoline, fuel oil, • Use the Basement Watchdog control unit for a 3-prong grounded plug. To reduce the risk of kerosene, etc. Glentronics, Inc.
  • Page 3: System Specifications

    Introduction Model CITS-50 The Basement Watchdog combination sump pump system Rubber is designed to provide both primary and backup pumping capabilities. The primary pump will operate as long as Union it is receiving AC power. If the power is interrupted or...
  • Page 4: Installing The Pipe And Pump

    Place a pump stand or bricks on the The Basement Watchdog combination system is pumps). They should be tight. wires with the cover. The pit cover usually has an floor of the sump pit to raise the pump above the compact and will fit in a sump pit as small as 12”...
  • Page 5: Preparing The Battery

    Use 1.265 specific gravity battery acid to The Basement Watchdog Big Standby battery fill the battery. It is available where you purchased has been designed to run this system for 60 the battery.
  • Page 6: Battery Maintenance

    If the metal tools on the battery dries out, the system will not work. battery. If battery CHARGER acid contacts eyes, If you are using The Basement Watchdog PUMP flush with water Maintenance Free Battery or a another brand...
  • Page 7: Connecting The Charger

    (6b). Review photos on the bottom The control unit for the Basement Watchdog a protective cage. Water will lift the bottom float • If the fourth light on the controller is also on, of page 5.
  • Page 8: Cleaning The Battery Terminals

    If necessary, fill the battery following the When another charger is used, first disconnect 4. Remove the fluid sensor from the battery. Unscrew instructions on page 4. the Basement Watchdog charger from the the wing nuts. Remove the battery cables. Page 7...
  • Page 9 pump wires to make sure they are connected 3. Fan the area around the top of the battery with securely to the pump plug. Check the rest of a piece of cardboard (or another nonmetallic the pump wires for any possible breaks. material) to remove any hydrogen or oxygen gas that may have been emitted from the 2.
  • Page 10: Replacing The Backup Pump

    • Check the main AC pump for failure. It may not be working, the float switch may be stuck, or CHARGER the pump may be too small to handle the inflow of water. PUMP • Ensure the check valve is working. FUSE •...
  • Page 11: Replacing The Primary Pump

    Before begin on the backup pump, the primary float, and handle on the primary pump. During this emergency, the Basement Watchdog this process you will primary pump. Remove the wye pipe. system will automatically switch to battery power need a new AC pump.
  • Page 12: System Operating

    CONNECT MODULE System Operating – LED Light button to silence the alarm. If the YELLOW button The CITS-50 can be connected to a home security The Basement is pressed before the pump has stopped, the alarm This light will always be on when power is coming system or other alarm devices to alert you to a Watchdog CONNECT®...
  • Page 13: Maintenance Checklist

    You can receive technical support, parts or service information by calling Glentronics, Inc. at 800-991- WYE PIPE 0466, option 3, or by visiting the Basement Watchdog website at www.basementwatchdog.com. Send your unit to the following address for repairs: Glentronics, Inc.
  • Page 14: Troubleshooting Guide

    Primary Pump Troubleshooting Guide Backup Pump Troubleshooting Guide DANGER DANGER Read safety warnings & instructions before attempting any repairs or maintenance. Read safety warnings & instructions before attempting any repairs or maintenance. THE PUMP WILL NOT START OR RUN BATTERY FLUID LOW Potential Cause Solutions Potential Cause...
  • Page 15 Limited Warranty By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.
  • Page 16: Maintenance-Free Battery

    Additional Products to Help Protect Your Basement Basement Wash-Dog Maintenance Free Battery Water Alarms Sewage Pump SUMP SYSTEM CLEANER BW-27AGM BW-WA360 SW-50T WDT20 1/2 HP FEATURES AND BENEFITS:  Patented design allows it to detect water on any side  Senses as little as ¹/₃₂” of water  Compact size (23/8”...