Technical support Connecting the battery Replacement Parts Diagram & List 12 IMPORTANT: Even if you have the Basement Watchdog sump pump system installed by Connecting the charger Connecting the primary pump someone else, you must read and follow the safety information contained in this manual.
Return the product to the manufacturer for any attempting any maintenance or cleaning. • Use the Basement Watchdog control unit for POSITIVE NEGATIVE repairs at the following address: charging a LEAD-ACID battery only. DO NOT •...
Introduction The Basement Watchdog combination sump pump system is designed to provide both primary and backup pumping capabilities. The primary pump will operate as long as it is receiving AC power. If the power is interrupted, or more Backup Pump...
(primary and backup pumps). stand or bricks on the floor of the sump pit to They should be tight. The Basement Watchdog combination system is raise the pump above the debris. 12. Position the top of the pump compact and will fit in a sump pit as small as...
Within 15-30 minutes of adding acid, the battery paper towels or newspaper on top of it while you designed to fit the Basement Watchdog will be 70-80% charged. The system will then are filling the battery. Place the dry (unfilled) batteries.
(b) Secure the controller to the side of the battery. It may damage the vent. the Basement Watchdog package. An arrow on discharge pipe by wrapping the tie around the When you fill the battery for the FIRST time, 3.
Warnings & Alarms the water reaches that level. As the water recedes below the float switch, a timer in the The Basement Watchdog backup control unit control unit will run the pump an additional features a series of warning lights that pinpoint 25-30 seconds to evacuate the pit.
2. Check the charger. Make sure it is securely POWER and/or the on page 4. (The Basement Watchdog battery or in the molded hole on the top of the plugged into the wall outlet. Make sure the...
• Check the main pump for failure. It may not DANGER be working, the float switch may be stuck, or Risk of electrical shock or battery explosion, the pump may be too small to handle the which can cause serious injury or death. inflow of water.
Page 10
hydrogen or oxygen gas that may have been 24. Connect the top of the system to the rubber emitted from the battery. union and tighten the hose clamp. 5. Remove the sensor from the battery. 25. Connect the battery cables to the battery terminals, WHITE to the NEGATIVE (-) post, 6.
immediate action needs to be taken to replace If the battery is relatively new and the battery the battery or clean the terminals. This alarm alarm is activated, before you replace the will sound when: battery, call the Glentronics service department. The phone number is 800-991-0466, option 3.
another nonmetallic material) to remove any TEST BUTTON pump will run for an additional 10 seconds after hydrogen or oxygen gas that may have been the float returns to the original position. It will The TEST button may be used to check the emitted from the battery.
Replacement Parts List BOTTOM VIEW Description Part No. 1/3 HP AC sump pump SIT-33NS Caged dual float switch with piggyback controller BWC2 Emergency backup pump 1011004 Emergency control unit BWE-CONT “Y” PVC pipe fitting 1120007 Support bracket for backup pump 1121003 Battery cap with hole for the fluid sensor 1125000...
Primary Pump Troubleshooting Guide Backup Pump Troubleshooting Guide DANGER DANGER Read safety warnings & instructions before attempting any repairs or maintenance. Read safety warnings & instructions before attempting any repairs or maintenance. Potential Cause THE PUMP WILL NOT START OR RUN Solutions Potential Cause BATTERY FLUID LOW...
Page 15
Limited Warranty By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.