Connecting the Charger Other Products IMPORTANT: Even if you have the Basement Watchdog Special Backup Sump Pump System installed by someone else, you must read This manual is for the systems that and follow the safety information contained in this manual. Failure have the BWSP-A backup controller, to do so could result in property damage, serious injury, or death.
Risk of electrical and fire hazard. May result • When connecting the battery cables, first BATTERY PREPARATION • Use the Basement Watchdog control unit for in death, serious injury, shock or burns. connect the small ring on the end of the charging a LEAD-ACID battery only.
Should any malfunction or emergency Fluid Sensor occur that involves the sump pump, the battery, or the AC power, the Basement Watchdog system will Pump sound an alarm. A light on the display panel of the control unit will indicate the cause of the alarm •...
NARROW SUMP PIT INSTALLATIONS If the direct discharge method is not possible or convenient, the Basement Watchdog pump can FLOOR FLOOR be connected to the same line as your main AC JOIST...
1/8” hole must be drilled in INSTALLATION A: the PVC pipe above the Basement Watchdog DIRECT DISCHARGE TO THE OUTSIDE OF THE 4. Attach a union or a check valve to the top of pump. Drill the hole at a 45° angle toward BUILDING (Diagram A) the 1½”...
2. Install a check valve on the top of the PVC and cement the top of the “Y” assembly to the PVC PIPE pipe attached to the Basement Watchdog discharge pipe with the “Y” extension facing pump. Make sure it is installed with the arrow down toward the backup pump.
20 feet of pipe.) onto the mounted strainer. a 1/8” hole must be drilled in the PVC pipe above the Basement Watchdog pump. Drill the INSTALLATION C: 3. Secure the pump wire so that the plug on the hole at a 45°...
Page 8
If a 1/8” hole attached, simply press the rest of the pump check valve of the Basement Watchdog pump, together until you are sure they are cut to the is not drilled above the pump, an air lock onto the mounted strainer.
The battery will be charged 70-80% 30 minutes COME IN TWO CONFIGURATIONS. THE TOPS OF THE after adding acid. The system will then finish The Basement Watchdog Big Standby battery has BATTERIES LOOK DIFFERENT, AND THE DIRECTIONS charging the battery. During this time the alarm...
time and give off a sulfur-like smell, but this is Control Unit Connections normal. After the battery has been filled, press DANGER the caps securely on the top of the battery. Risk of electrical shock or battery explosion, CAUTION which can cause serious injury or death. When you fill the battery for the FIRST time, Unplug the main AC pump to avoid electrical it will be the ONLY time you add acid to the...
WATER IF CHECK LEVEL 1/8” HOLE that is provided in the Basement Watchdog If you are not using the Basement Watchdog VALVE USED LINE package. An arrow on the top of the battery Standby battery, you cannot use the battery FLOAT SWITCH marks this position.
Understanding the before you replace the battery. connecting it to your car battery. The Basement Watchdog Special allows you to Warnings & Alarms • If the bottom light on the controller is also silence some of the alarms during an emergency,...
TO CLEAN THE BATTERY TERMINALS front and back of the box. AND CABLES 9. Plug the charger back into the wall outlet. (You should provide additional protection for DANGER the control unit by using a surge protector.) Risk of electrical shock or battery explosion, 10.
(b) If your battery has two caps, each fuse holder. (b) If the wires are burned and on page 8. (The Basement Watchdog battery broken, replace the fuse with a 20 amp DC covering three (3) battery cells, simply insert filler will automatically fill the level to the safety fuse.
Pump When the water rises in the sump pit and PUMP CH RGER activates the float switch, the pump will begin FUSE pumping, and the “Pump was activated” light and alarm will turn on. Try to determine what caused the system to activate. •...
You will need to extend wires from is needed to prevent an air lock within the the security system to the Basement Watchdog 110 volts will activate the power failure alarm. To test the pump, press the YELLOW button for 1 system.
9. Check battery fluid levels once every four • Connects using Z- months. Wave Plus The Basement Watchdog Connect Modules are separately sold accessories that will allow the user to stay connected and receive remote Model No. BW-HZM notifications of potential problems and needed maintenance while away from home.
The fluid sensor should be inserted into the designated hole on the top of the Basement Watchdog battery and pushed down Not using a Basement Watchdog battery ....
LIMITED WARRANTY By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.
If you’ve spent any time in your basement, You can detect leaks before they become bigger The Basement Watchdog line of AC sump pumps It’s probably the result of a float switch that is you’ve probably noticed your sump pump turning...
Need help?
Do you have a question about the Special CONNECT and is the answer not in the manual?
Questions and answers