Download Print this page
The Basement Watchdog SIT-33D Instruction Manual & Safety Warnings

The Basement Watchdog SIT-33D Instruction Manual & Safety Warnings

Sump pumps

Advertisement

Available languages

Available languages

Quick Links

Basement Watchdog
Sump Pumps
Instruction Manual &
Safety Warnings
Models SIT-33D
and
SIT-50D
Para instrucciones
en español ver
página 5
Voir instructions
en français
à la page 9
Items Included:
Pump
Dual float and controller
Stainless steel hose clamp
⅓ HP Pump
½ HP Pump
SIT-33D
SIT-50D
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS
and OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to
refer to it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
Risk of electric shock. To reduce this risk, observe the
WARNING
!
following precautions.
• ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
• NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
• MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a
2-prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
• NEVER bypass grounding wires or remove the ground prong from the plug.
• DO NOT use an extension cord. The electrical outlet should be within the length of
the pump's power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
• DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
• MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle
the power requirements noted on the nameplate of the pump.
To reduce the risk of hazards that can cause injury or
CAUTION
!
property damage, observe the following precautions.
• DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
• DO NOT pull on the float switch cord.
• DO NOT expose the control unit to water, rain or snow.
• DO NOT place the controller on the floor. The electrical outlet should be within the
length of the pump's power cord and at least 4 ft above the floor.
• DO NOT operate the pump or control unit if it has been damaged in any way.
• DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous
liquids. This product is for ground water use only.
• DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
When installing or replacing a primary sump pump you should also install a battery
backup sump pump system.
Specifications
⅓ HP Model SIT-33D
GPH @ 0'
GPH @ 10'
Pump diameter
Volts
115V, 60Hz
Amps
Dual Float
& Controller
½ HP Model SIT-50D
3720
4400
3100
3540
6.2"
6.2"
115V, 60Hz
3.5
4.2
You may also need:
A 1½" PVC pipe adapter to screw
into the discharge hole on top of
the pump
1½" rigid PVC pipe to connect to
the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIT-33D and is the answer not in the manual?

Questions and answers

Summary of Contents for The Basement Watchdog SIT-33D

  • Page 1 Important Safety Instructions Sump Pumps SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING INSTRUCTIONS for the Basement Watchdog pumps. You will need to refer to it before attempting any installation or maintenance. Instruction Manual & ALWAYS keep these instructions with the unit so that they will be easily accessible.
  • Page 2: Installation Instructions

    NOTICES • The Basement Watchdog SIT-33D and SIT-50D come equipped with a built-in air relief valve located on the top of the pump. While the pump is active, some water may come out of the valve. This is normal. The valve is needed to prevent an air lock within the pump.
  • Page 3: Maintenance Checklist

    Backup Installation Dual Float Controller This control box contains a piggyback switch that powers When the power goes out, the Basement Watchdog Dual Float. The Dual Float Basement Watchdog Controller will activate the pump when either float is lifted, AC sump pumps will not and then shuts off automatically 10 seconds after the float operate.
  • Page 4 Additional Products to Protect Your Home BATTERY BACKUP CHECK VALVE SUMP PUMP SYSTEM BW-CVK15 BWSP FEATURES AND BENEFITS: Protect your basement • Muffles sound normally made from flooding due when a sump pump shuts off to power loss, pump • Designed for a quick, easy failure, float issues, install or excess water.
  • Page 5: Instrucciones De Seguridad Importantes

    Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069 • Cuando instale o reemplace una bomba de sumidero primaria debería también instalar un sistema de bomba de sumidero de respaldo a batería. Especificaciones ⅓ HP Modelo SIT-33D ½ HP Modelo SIT-50D GPH @ 0'...
  • Page 6: Instrucciones De Instalación

    AVISOS • Las Basement Watchdog SIT-33D y SIT-50D vienen equipadas con una válvula de alivio de aire incorporada ubicada encima de la bomba. Mientras la bomba está activa, puede salir un poco de agua de la válvula. Esto es normal. La válvula es necesaria para evitar un bloqueo de aire dentro de la bomba.
  • Page 7: Garantía Limitada

    dentro de una jaula protectora. El agua elevará el flotador 4. Quite todos los escombros alrededor de la válvula de alivio de aire. inferior en un 1⁄4 de pulgada, lo que activará la bomba. Si 5. Llene el pozo con agua. Asegúrese de que la bomba se encienda al nivel por alguna razón el flotador inferior no activase la bomba, el deseado.
  • Page 8: Guía De Solución De Problemas

    Productos adicionales para proteger su hogar SISTEMA DE VÁLVULA DE RETENCIÓN – BOMBA DE BW-CVK15 SUMIDERO DE CARACTERÍSTICAS Y BENEFICIOS: RESPALDO A • Amortigua el sonido que realiza BATERÍA – BWSP normalmente cuando se apaga la bomba de sumidero Proteja el sótano •...
  • Page 9: Consignes De Sécurité Importantes

    Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069 • Lors de l'installation ou du remplacement d'une pompe de puisard primaire, vous devez également installer un système de pompe de puisard de secours à batterie. Spécifications ⅓ HP Modéle SIT-33D ½ HP Modéle SIT-50D GPH @ 0' 3720...
  • Page 10: Instructions D'installation

    AVIS • Les pompes Basement Watchdog SIT-33D et SIT-50D sont équipées d'une soupape de sûreté intégrée située sur le dessus de la pompe. Lorsque la pompe est active, un peu d'eau peut s'écouler de la soupape. Ceci est normal. La soupape est nécessaire pour éviter un blocage d'air à...
  • Page 11: Liste De Contrôle De L'entretien

    une raison quelconque, le flotteur inférieur n'active pas la pompe, l'eau monte et 6. Pendant que la pompe fonctionne, assurez-vous qu'elle évacue l'eau à un bon active le second interrupteur. Au fur et à mesure que la pompe évacue l'eau de rythme.
  • Page 12: Guide De Dépannage

    Produits supplémentaires pour protéger votre maison SYSTÈME DE CLAPET ANTI-RETOUR POMPE DE PUISARD BW-CVK15 À BATTERIE DE CARACTÉRISTIQUES ET AVANTAGES: SECOURS • Atténue le son normalement BWSP produit lorsqu'une pompe de puisard s'arrête Protégez votre sous- • Conçu pour une installation sol des inondations rapide et facile dues à...

This manual is also suitable for:

Sit-50d