Download Print this page

Advertisement

Quick Links

USER MANUAL
ENGLISH - VERSION 2
2 Rue de Vitruve,
91140 Villebon-sur-Yvette,
France
USER MANUAL _
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the VELOCE PROFILE ULTIMATE IP65 6 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ayrton VELOCE PROFILE ULTIMATE IP65 6 Series

  • Page 1 USER MANUAL ENGLISH - VERSION 2 2 Rue de Vitruve, 91140 Villebon-sur-Yvette, France USER MANUAL _...
  • Page 2: Table Of Contents

    VELOCE PROFILE | ULTIMATE IP65 6 SERIES CONTENTS 1. SAFETY INSTRUCTIONS ..............................................3 2. FEATURES ....................................................4 3. FIXTURE OVERVIEW ................................................4 4. DRAWINGS ....................................................4 5. INSTALLATION INSTRUCTIONS ............................................. 6 6. DMX-512 CONTROL CONNECTION ..........................................6 7. DMX-512 CONNECTION WITH DMX TERMINATOR ..................................... 7 8.
  • Page 3: Safety Instructions

    VELOCE PROFILE | ULTIMATE IP65 6 SERIES 1. SAFETY INSTRUCTIONS ƒ This device falls under protection-class I. Therefore, it is essential that the device be earthed. 1.1 IMPORTANT SAFETY WARNINGS ƒ If either lenses or display are damaged (damage may include This device has left the factory in perfect condition.
  • Page 4: Features

    VELOCE PROFILE | ULTIMATE IP65 6 SERIES 2. FEATURES COOLING SYSTEM ƒ Advanced liquid cooling system POWER SUPPLY ƒ Selectable ventilation user modes ƒ AC100-240 V~, 50/60 Hz ƒ Excess temperature protection ƒ Power Consumption: 1,300 W HOUSING OPTICS ƒ Skeleton made of aluminium ƒ...
  • Page 5: Rotating Gobo Wheel

    17mm 17mm 1.1mm 1.1mm 2.2mm 2.2mm Image Image VELOCE PROFILE | ULTIMATE IP65 6 SERIES Thickness Thickness Thickness Thickness 4.3 ROTATING GOBO WHEEL 30mm 30mm 0.15 0.15 Rotating Gobo: Rotating Gobo: Glass Glass Black & White Black & White 1.8mm 1.8mm 0.15 0.15...
  • Page 6: Animation Wheel

    VELOCE PROFILE | ULTIMATE IP65 6 SERIES 4.4 ANIMATION WHEEL Ø 100 mm Omega bracket Safety rope Clamp Quick-lock fastener 5. INSTALLATION INSTRUCTIONS 5.3 RIGGING DRAWINGS 5.1 RIGGING THE DEVICE CAUTION CAUTION Overhead rigging requires extensive experience, including (but not Please consider the respective national norms during the limited to) calculating working load limits, specifying installation/ installation.
  • Page 7: Dmx-512 Connection With Dmx Terminator

    VELOCE PROFILE | ULTIMATE IP65 6 SERIES 9.2 MESSAGE FROM THE LED INDICATOR DMX Output DMX Output DMX Input DMX Input 5-Pin XLR Socket 5-Pin XLR Socket 5-Pin XLR Socket 5-Pin XLR Socket ƒ Rapid flashing red/Green: Logging in to a transmitter. 1: Ground 1: Ground ƒ...
  • Page 8: Display

    VELOCE PROFILE | ULTIMATE IP65 6 SERIES • Do not connect the fixture which is under the communication Options of wireless system to the DMX controller, otherwise it will cause interference from the DMX controller. Fans Fans Speed Auto Fans Speed select Control Stage Silence...
  • Page 9 VELOCE PROFILE | ULTIMATE IP65 6 SERIES display will show “DMX Address: 001-XXX”, “Decimal Universe: Info XXXXX”, “Net: XX”, “Sub-Net: X”, “Universe: X”, “Signal: DMX/ WDMX/Art-Net/sACN”. Encoder Encoder Info Info ƒ Double-click the center button to confirm or long press the center button to return to the main menu.
  • Page 10 VELOCE PROFILE | ULTIMATE IP65 6 SERIES ƒ Tap the <Up/Down> button until “Options” is displayed. ƒ Tap the <Up/Down> button until “Options” is displayed. ƒ Double-click the center button to access “Options”. Tap the <Up/ ƒ Double-click the center button to access “Options”. Tap the <Up/ Down>...
  • Page 11 VELOCE PROFILE | ULTIMATE IP65 6 SERIES CMY Spd DMX Output ƒ Double-click the center button to access main menu. ƒ Double-click the center button to access main menu. ƒ Tap the <Up/Down> button until “Options” is displayed. ƒ Tap the <Up/Down> button until “Options” is displayed. ƒ...
  • Page 12 VELOCE PROFILE | ULTIMATE IP65 6 SERIES ƒ Tap the <Up/Down> button until “Options” is displayed. the <Up/Down> button to select “Clr Error Info”. ƒ Double-click the center button to access “Options”. Tap the <Up/ ƒ Double-click the center button to access “Clr Error Info”. The Down>...
  • Page 13 VELOCE PROFILE | ULTIMATE IP65 6 SERIES 10.3.8. Dim Curve With this function you can activate the automatic key lock function. If this function is activated. the keys will be locked automatically ƒ Double-click the center button to access main menu. after exiting the edit mode for 15 seconds.
  • Page 14 VELOCE PROFILE | ULTIMATE IP65 6 SERIES 10.3.14. Trigger ƒ Double-click the center button to access “Reset User” menu. Tap the <Up/Down> button to select “Address”. DMX Value Disp. ƒ Double-click the center button to access “Address”. The display With this function you can display the DMX 512 value of each will show “DMX Address: 001-XXX”, “Decimal Universe: XXXXX”, channel.
  • Page 15 VELOCE PROFILE | ULTIMATE IP65 6 SERIES Ttl Life Hrs button to return to the main menu. With this function. you can display the running time of the device. The display shows “XXXX”. “XXXX” stands for the number of hours. 10.4.2.
  • Page 16 VELOCE PROFILE | ULTIMATE IP65 6 SERIES 10.4.8. Signal Quality ƒ Double-click the center button to access main menu. ƒ Double-click the center button to access main menu. ƒ Tap the <Up/Down> button until “Test” is displayed. ƒ Tap the <Up/Down> button until “Info” is displayed. ƒ...
  • Page 17: Nfc

    When the fixture is powered on, you can use a NFC smartphone located in the default position after the reset. installed with the Ayrton App to scan the NFC tag area of the fixture to read some of the information or settings inside the display menu,...
  • Page 18 VELOCE PROFILE | ULTIMATE IP65 6 SERIES Cyan Colour wheel Er Blade 1 wheel Er (Cyan Colour wheel- error) This message will appear after the reset (Blade 1 wheel- error) This message will appear after the reset of of the fixture if the head’s magnetic-indexing circuit malfunctions the fixture if the head’s magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (sensor failed or magnet missing) or the stepper motor is defective...
  • Page 19: Cleaning And Maintenance

    Warning! Do not place the fixture with its lens/ glass facing any people while doing the IP test! Never use alcohol or solvent to clean the lenses. Always run an IP test using the Ayrton IP test kit following any maintenance operation! 1: Ground 1: Ground...
  • Page 20 2 Rue de Vitruve - 91140 - Villebon-sur-Yvette-France...