Airius II Wi-Fi error codes ..........................7 4.2.1 Summative troubleshooting guide ......................7 Airius II LTE-M error codes – applicable when CES Service Connector is used* ..........8 4.3.1 Summative troubleshooting guide ......................8 Finding the Airius II firmware version ......................10 SPM Connect app ............................
3. The LED will start flashing blue once every second, indicating Bluetooth mode. The sensor is now connectable from the SPM Connect app. When Airius is connected to the SPM Connect app, the LED will start flashing blue more frequently. SPM Instrument AB I Box 504 I SE-645 25 Strängnäs I Sweden Technical data subject to change without notice.
NOTE: We strongly advise against performing a factory reset – it should only be done on the advice of SPM Support. A factory reset resets all settings and reverts the firmware version to the one installed during factory production. If you wish to reset the settings, it is better to use the 'Clear settings' function in the SPM Connect app to avoid any complications.
NOTE: This behavior is valid from firmware version 2.1.9.9. If an already activated Airius II LTE-M sensor has been physically moved to another location, the LTE-M network conditions might have changed, and Airius might need to connect to the network via another cell phone tower or another operator.
** Might be perceived as white. For a full understanding of the LED behaviors, please refer to the preceding text and the error code tables. SPM Instrument AB I Box 504 I SE-645 25 Strängnäs I Sweden Technical data subject to change without notice.
Airius failed to connect to CES. flash NOTE: The long/short flash behavior is valid from firmware version 2.1.9.9. For earlier Airius II firmware versions, the red flash means that Airius failed to connect to the Wi-Fi access point or CES.
* For solutions where CES Service Connector is not used – contact SPM Support. NOTE: The long/short flash behavior is valid from firmware version 2.1.9.9. For earlier Airius II firmware versions, the red flash means that Airius failed to connect to the LTE-M network or CES Service Connector.
Page 9
The computer or CES might have network or performance issues. Restart the computer and/or CES as necessary. SPM Instrument AB I Box 504 I SE-645 25 Strängnäs I Sweden Technical data subject to change without notice. Tel +46 152 22500 I info@spminstrument.se I www.spminstrument.com...
3. Select the Airius online unit and check its Device info. NOTE 1: Remember that Bluetooth mode draws significant battery power. NOTE 2: In versions older than 2.2.6 of the SPM Connect app, 'Firmware version' is called 'Software version'. Condmaster.NET 1.
• Set Airius in Bluetooth mode (NOTE: Bluetooth mode draws significant battery power) and select 'Check RSSI' in the SPM Connect app. If something is wrong, a red x and an error message are shown. SPM Instrument AB I Box 504 I SE-645 25 Strängnäs I Sweden Technical data subject to change without notice.
Need help?
Do you have a question about the AIRIUS II and is the answer not in the manual?