Download Print this page

HOMCOM 823-002V70 Owner's Manual page 21

Advertisement

5.4.3. TIMER SETTING
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Cancel timer
5.4.4.
Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during operation.
The unit will automatically start defrosting and the POWER LED blinking. The
defrost control sequence is as follows:
A. When the unit operates in the cooling operation, drying operation, the
ambient temperature sensor senses the evaporator coil temperature is below
-1°C, after the compressor will stop operating for 10 minutes or the coil
temperature up to 7℃, the unit restart to cool operating mode.
B. When the unit operates in the heating operation, drying operation, once the
coil temperature sensor senses the temperature of the evaporator is below 40
℃ and the differential temperature between coil temperature and room
temperature is below 19℃ after the compressor operation for 20minutes, the
unit start defrosting for 5 minutes and the power indicator blinking.
5.4.5.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay
until the compressor restarting.
(1hour-24hours):
Press Timer key to
turn on the timer
function.
Press Timer key to
turn on the timer
function.
Press Timer key ,then press ADD/MINUES repeatedly
until the LED shows '00'.
Note: when press POWER will also exit the timer setting.
Press ADD/MINUS
repeatedly to set the
delay OFF time.
Press ADD/MINUS
repeatedly to set the
delay ON time.
21

Advertisement

loading
Need help?

Need help?

Do you have a question about the 823-002V70 and is the answer not in the manual?

Questions and answers

Cory Wilbourn
March 27, 2025

Fe flashing on unit

This manual is also suitable for:

823-002v90823-002v71823-002v91823-002v92