HOMCOM 823-005V72/005V70/005V71 - Local Portable Air Conditioner for Cooling Manual

HOMCOM 823-005V72/005V70/005V71 - Local Portable Air Conditioner for Cooling Manual

Also See for 823-005V72:

Advertisement

HOMCOM 823-005V72/005V70/005V71 - Local Portable Air Conditioner for Cooling Manual

PRODUCT OVERVIEW

PRODUCT DIAGRAM

PRODUCT DIAGRAM

  1. Control panel
  2. Air outlet with adjustable louver
  3. Air outlet with adjustable louver
  4. Power cord
  5. Recessed handle
  6. Air Exhaust
  7. Drain opening with sealing plug

warning Note: The appearance is only for reference. Please see the real product for detailed information.

FEATURES

  • High Capacity in a compact size with cooling, heating, dehumidifying and ventilating function.
  • Temperature setting and display
  • LED Digital display
  • Electronic control with built-in timer, sleep mode
  • Self-evaporating system for better efficient
  • Auto shut off when tank full
  • Automatic restart in the event of power outage
  • Auto defrosting function at low ambient temperatures
  • Remote control
  • 2- speed fan
  • Casters for easy mobility

INSTALLATION

UNPACKING

  • Unpack the carton and take the appliance and accessories out.
  • Check the device after unpacking for any damage or scratches on it.
  • Accessories:
    1. Exhaust hose
    2. Hose connector
    3. Window kit adapter
    4. Remote control
      Accessories - Part 1
    5. Window kit
      Accessories - Part 2

Choose your location

  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
  • Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
  • Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
  • Never install the unit where it could be subject to:
    • Heat sources such as radiators, heat registers, stoves or other products that products that produce heat.
    • Direct sunlight
    • Mechanical vibration or shock
    • Excessive dust
    • Lack of ventilation, such as cabinet or bookcase
    • Uneven surface


Install the unit in rooms which exceed 7 m² for 5000- 7000BTU/h model, 8m² for 8000BTU/h model, 9m² for 9000BTU/h model, 10m² for 10000BTU/h model.
Do not install the unit in a place where inflammable gas may leak.

warningNOTE!
The manufacture may provide other suitable example or may provide additional information about the refrigerant odour.

ATTACH THE EXHAUST HOSE

The air conditioner requires being vented outside so that the exhaust air can escape the room which coming from the appliance contains waste heat and moisture.
Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low backpressure.

Step 1: Connect the hose connector to one end of the exhaust hose.
ATTACH THE EXHAUST HOSE - Step 1

Step 2: Connect the windows kit adapter to the other end of the exhaust hose.
ATTACH THE EXHAUST HOSE - Step 2

Step 3: Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit.

Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
ATTACH THE EXHAUST HOSE - Step 3

Step 5: Attach the hose connector to the exhaust air outlet of unit.

Step 6: Adjusting the length of the flexible exhaust hose, and avoid bends in the hose. Then place AC near an electrical outlet.

Step 7: Adjust the louver at the air outlet, and then switch on the unit.

OPERATION

CONTROL PANEL AND DISPLAY

CONTROL PANEL AND DISPLAY

REMOTE CONTROL

FUNCTION KEYS AND INDICATORS

1. POWER (LED) Press to switch the machine on or off.
2. UP Increasing the desired temperature(16 ℃ ~ 32 ℃) or timer setting.
3. MINUS Decreasing the desired temperature or timer setting.
4. Mode Mode button Press to switch the operation mode between cool, fan, and dry.
5. Speed Press to switch the fan speed between HIGH and LOW
6. TIMER Sets a time for the unit to automatically start or stop.
7. Locker Press to turn on or turn off child lock function.
8. Indicators LED for fan speed (high & low)
9. Indicators Display to show temperature or setting time.
10. Indicators LED for four operation modes selecting by press mode button.

SETTINGS

Start-up and Shutdown

  • Press POWER to turn the unit on. The unit runs in in FAN as default.
  • Press MODE button to select the desired operation mode.
  • Press POWER again to turn off the power.

Operation mode

The unit has five operation modes: Cool, heat, fan, dry, sleep.

  1. Cooling your room
    Select the cool mode to lower the temperature in your room.
    • Press MODE button repeatedly until the LED of COOL operation lights up.
    • Press ADD/MINUS button to adjust the temperature which is displayed on the screen. The temperature can be set between 16℃ and 32℃.
    • Press SPEED button repeatedly until the desired fan speed indicator lights up. To control the direction of the air flow horizontally, please adjust the inner louver by hand.
      warning Note: The air conditioner stops if the room temperature is lower than selected temperature.
  2. Heating your room(Optional for Heating Function Unit only)
    • Press MODE button repeatedly until the LED of HEAT operation lights up.
    • Press ADD/MINUS button to set the temperature higher than the room temperature. The fan speed can also be set.
      warning Note: The drainage hose should be attached to the unit for continuous operating.
  3. Ventilating your room
    • Press MODE button repeatedly until the LED of FAN operation lights up. In ventilation mode the room air is circulated, but not cooled.
    • Press SPEED button repeatedly to select the fan speed as desired.
  4. Drying your room
    • Press MODE button on the control panel or remote control, the LED of DRY operation lights up. The fan speed is unable to select. User should connect the hose to the drain outlet at the bottom of the unit.
      warningNote: In this mode, the fan speed switches over to low speed and cannot be selected.
  5. Sleep mode(this function can only be used with a remote control)
    The sleep mode can be activated when in cool mode and heat mode.
    • In cool mode:
      After 1 hour the preset temperature is increased by 1 ℃, after another hour the preset temperature will again be increased by 1 ℃.
    • In heat mode(Optional for Heating Function Unit only) :
      After 1 hour the preset temperature is decreased by 1 ℃, after another hour the preset temperature will again be decreased by 1 ℃.

Then the temperature is kept constant for 10 hours. And all the indicators dim to dark. The fan speed may switch over to low speed for silent operating and cannot be selected.

TIMER SETTING

(1hour-24hours):

The timer has two ways of operation:

To turn off
(When power on)
Press Timer key to turn on the timer function. Press ADD/MINUS repeatedly to set the delay OFF time.
To turn on
(When power off)
Press Timer key to turn on the timer function. Press ADD/MINUS repeatedly to set the delay ON time.
Cancel timer Press ADD/MINUES repeatedly until the LED shows '00'.
warning Note: when press POWER will also exit the timer setting.

Automatic Defrost

At low room temperatures, frost may buildup at the evaporator during operation. The unit will automatically start defrosting and the POWER LED blinking. The defrost control sequence is as follows:

  1. When the unit operates in the cooling operation, drying operation, the ambient temperature sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop operating for 10 minutes or the coil temperature up to 7℃, the unit restart to cool operating mode.
  2. When the unit operates in the heating operation, drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 40 ℃ and the differential temperature between coil temperature and room temperature is below 19℃ after the compressor operation for 20minutes, the unit start defrosting for 5 minutes and the power indicator blinking.

Overload Protection

In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.

DRAINAGE

Self- evaporating system

The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. It is no need to empty the drainage tank in cooling operation except in heating operation, drying operation and high humidity conditions. The condensate water evaporates at the condenser and evacuated through the exhaust hose.

For continuous operation or unattended operating in drying and heating operation, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity.

  • Switch off the unit before operating.
  • Remove the plug of the water outlet opening, and keep it in safe area.
  • Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
  • Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
  • Do not submerge the end of hose into water; otherwise it can cause "Air Lock" in the hose.
Self- evaporating system - Step 1
Self- evaporating system - Step 2
To avoid water spillage:
  • As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
  • Straighten the hose to avoid a trap existing in the hose.

CLEANING AND CARE

CLEANING THE AIR FILTER (every two weeks)

Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to suck dust from the filter.
  4. Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.


Pic1. Switch off the unit and remove the two air filters.


Pic2. Rinse the air filter under running water.


Do not touch the evaporator surface with bare-hand, or could cause injury of your fingers.

CLEANING UP OF REFRIGERANT

General Measures:

  1. Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level.
  2. Eliminate every possible source of ignition.
  3. Use appropriate personal protection equipment (PPE).
  4. Evacuate unnecessary personnel, isolate, and ventilate area.
  5. Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
  6. Prevent entry to sewers and public waters.
  7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
  8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill.

TROUBLESHOOTING

Symptom Inspection Solution
The unit is not operating. Check the power connection in securely. Insert the power cord securely into the wall Outlet.
Check if the water level indicator lights up? Empty the drain pan by remove the rubber plug.
Check the room temperature. The range of operating temperature is 5-35℃.
The unit works with reduced capacity. Check the air filter for dirt. Clean the air filter as necessary.
Check if the air duct is blocked. To clear the obstacle.
Check if the room door or window is open. Keep the door and windows closed.
Check if the desired operating mode is selected and the temperature is properly set. Set the mode and temperature at proper set- point according the manual.
The exhaust hose is detached. Make sure the exhaust hose is securely attached.
Water Leakage Overflow while moving the unit. Empty the water tank before transport.
Check if the drain hose is kinked or bends. Straighten the hose to avoid a trap existing.
Excessive Noise Check if the unit is securely positioned. Place the unit on horizontal and firm ground.
Check if any loose, vibrating parts. Secure and tight the parts.
Noise sounds like water flowing. Noise comes from flowing refrigerant. This is normal.
Error Codes E0 Communication faults between main PCB and display PCB. Check the wire harness of the display PCB for damage.
E1 Ambient temperature sensor failure Check connection or replace it. To clean or replace the temperature sensor.
E2 Coil temperature sensor failures. Check connection or replace it. To clean or replace the temperature sensor.
Ft Condensate water high level alarm. Empty the drain pan by removal the rubber plug.

DECOMMISSIONING

STORAGE

Long-Term Storage - If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps:

  1. Unplug the unit and remove exhaust hose and window kit store with the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Collect the power cord at the water tank.
  5. Re-install the filter at its position.
  6. The unit must be kept in upright position when in storage.
  7. Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.

warningATTENTIONwarning:
The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to set the humidity point more than 5% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.

US

001-877-644-9366
customerservice@aosom.com

CA

001-855-537-6088
customerservice@aosom.ca

UK

0044-800-240-4004
enquiries@mhstar.co.uk

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download HOMCOM 823-005V72/005V70/005V71 - Local Portable Air Conditioner for Cooling Manual

Advertisement

Need help?

Need help?

Do you have a question about the 823-005V72 and is the answer not in the manual?

Questions and answers

Table of Contents