Required tools
Ruler
Phillips and flat head
screwdriver
1
Prepare the door and check dimensions
If drilling a new door, use the supplied template and the complete
door drilling instructions available at www.kwikset.com/doorprep.
A
Measure to confirm the holes in the door
are 2-1/8 in (54 mm) and they measure
center to center 4 in or 5-1/2 in
(102 or 140 mm).
2-1/8 in
54 mm
2
Install the latches and strikes
A
Hold the latch in front of the door hole, with the latch
face flush against the door edge.
B
Is the rectangular shaped hole centered in the door hole?
YES
No adjustment is required.
Proceed to next step.
Kwikset
Technical Support
1-800-327-5625
www.kwikset.com
B
Measure to confirm that the backsets
are either 2-3/8 or 2-3/4 in (60 or 70 mm).
2-3/8 or 2-3/4 in
60 or 70 mm
4
102
or
or
140
5-1/2
mm
in
C
Is the door edge chiseled with round or square corners?
NO
or
D
Rotate latch face as
shown to extend latch.
Parts in the box
Latch Bolt
Plain Latch
Shield
Reinforcement
Plate
C
Measure to confirm that the holes in
the door edge are 1 in (25 mm).
b a
c k
s e
t
(2x)
For Latch /
Strike Bag
03809
Round Corner
No further prep needed.
Square Corner
Remove round face
with a flat head
screwdriver and use
square face in step E.
plain latch
latch bolt
Insert shield in the top interior door hole.
Make sure ARROW is pointing up
and the word "INSIDE" is facing
the interior of the door.
interior view
exterior view
(latch bolt installed)
(latch bolt installed)
1 / 4
Interior Assembly
For Latch / Strike
52469
Deadbolt
Strike
03809
Plain Latch Strike
53082
D
Measure to confirm that the door is
between 1-3/8 and 2 in (35 mm and
51 mm) thick.
1 in
25 mm
(2x)
(4x)
52469
actual size
(2x)
53082
E
Which latch face are you installing?
Round Corner
UP is on top.
52469
(2x)
When installing the latch bolt make sure the latch bolt is
placed into the edge bore hole and through the shield
that was placed in the top interior door hole in step 2D.
*Use longer screws if holes are worn out. You will
have 4 extra screws, 2 from each latch installation.
F
Install strike on the door frame.
Make sure the hole in the door frame is drilled a
minimum of 1 in (25 mm) deep.
Exterior Assembly
Traditional
Contemporary
For Lock
52300
Hex
Wrench
52301
Batteries
1-3/8 – 2 in
35 – 51 mm
(2x)
actual size
(2x)
actual size
Square Corner
or
UP is on top.
03809
03809
(2x)
(2x)
or
or
or
or
or
52469
or
or
(2x)
or
Longer screws install
closest to the door
jamb.
53082 (4x)
reinforcement
plate
52469 (2x)
(For Latch/
Strike Bag)
door frame

Advertisement

loading
Need help?

Need help?

Do you have a question about the UNITE 1100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kwikset UNITE 1100 Series

  • Page 1 Prepare the door and check dimensions If drilling a new door, use the supplied template and the complete door drilling instructions available at www.kwikset.com/doorprep. Measure to confirm the holes in the door Measure to confirm that the backsets Measure to confirm that the door is...
  • Page 2 Install the exterior assembly For Lock 52301 (4x) actual size Locate screws for step 3C(f) and keep Make sure adapter ring is on exterior them within reach. assembly. Diameter is 2-1/8 in 52301 (4x) (54 mm) (For Lock Bag) 2-1/8 in 54 mm Adapter ring is required for installation.
  • Page 3 (2x) For Lock Install the interior cover 52300 actual size Install interior cover onto interior chassis. Connect cable wire as shown. Ensure a tight cable Remove the battery cover from the interior cover. connection. Ensure the red color on the connector is on the top and connects to the red color on the interior assembly.
  • Page 4 Reference Guide Unite at a Glance System Alerts Exterior Operation Lights Beep Access Granted Status flashes GREEN 3x 1 Beep Programming Battery LED light LED light Access Denied Flashes RED 3x 3 Beeps Status 1 Long Beep Low battery life - Battery LED flashes RED 3x then 3 LED light...

This manual is also suitable for:

Unite 1100mil rdt 15Unite 1100dl rdt 15Unite 1100dl sqt 15Unite 1100brnl rdt 15Unite 1100mil sqt 15Unite 1100brnl sqt 15 ... Show all