Activating Flexaddress - Dell POWEREDGE M1000E Configuration Manual

Blade server
Hide thumbs Also See for POWEREDGE M1000E:
Table of Contents

Advertisement

For example:(starting_mac)00188BFFDCFA + 0xCF =
(ending_mac)00188BFFDDC9
NOTE:
You must lock the SD card prior to inserting in the USB "Memory Card
Reader" to prevent accidently modifying any of the contents. You must unlock the
SD card before inserting into the CMC.
FlexAddress Plus
The FlexAddress Plus is a new feature added to the feature card version 2.0.
FlexAddress Plus expands the number of MAC addresses to 3136 from the
original FlexAddress pool of 208.

Activating FlexAddress

FlexAddress is delivered on a Secure Digital (SD) card that must be inserted
into the CMC to provide the chassis-assigned WWN/MAC IDs. To activate
the FlexAddress feature, perform several required updates; if you are not
activating FlexAddress, these updates are not required. The updates, which
are listed in the following table, include server module BIOS, I/O mezzanine
BIOS or firmware, and CMC firmware. You must apply these updates before
you enable FlexAddress. If these updates are not applied, the FlexAddress
feature may not function as expected.
NOTE:
All systems purchased after June 2008 have the correct firmware versions
installed.
Component
Ethernet mezzanine card - Broadcom
M5708t
FC mezzanine card - QLogic QME2472 BIOS 2.04 or later
FC mezzanine card - Emulex LPe1105-
M4
Server Module BIOS
PowerEdge M600/M605 LAN on
motherboard (LOM)
iDRAC
44
Initial System Configuration
Minimum Required Version
Boot code firmware 4.4.1 or later
iSCSI boot firmware 2.7.11 or later
PXE firmware 4.4.3 or later
BIOS 3.03a3 and firmware 2.72A2 or
later
(PowerEdge M600) BIOS 2.02 or later
(PowerEdge M605) BIOS 2.03 or later
Boot code firmware 4.4.1 or later
iSCSI boot firmware 2.7.11 or later
Version 1.11 or later