Page 9
35 mg/m 112 mg/m 83 mg/m CO at 13% O 1115 mg/m CO at 13% O 0.09 % Energy efficiency index Energy efficiency class The Declaration of Performance (DoP) can be downloaded from our website, www.hwam.com. Page 9 of 24 pages...
Page 10
Height Width Dept WIKING Maxi 2 113 kg 59.2 cm 66.7 cm 36.3 cm WIKING Maxi 2 on a plinth 114 kg 60.8 cm 66.7 cm 36.3 cm WIKING Maxi 2 with low legs 114 kg 65.2 cm 66.7 cm 36.3 cm...
Page 11
Combustible materials may not be placed underneath WIKING Maxi 2. WIKING Maxi 2 with a plinth and WIKING Maxi 2 with low legs must not be placed on combustible floors. It is still considered a combustible floor even if an ember catching, a non-combustible floor plate is placed on top of the combustible floor.
Page 12
A top flue blanking plate can be bought as an accessory to cover the hole in the top plate of the stove if the stove is connected to a back outlet. Changing the Smoke Outlet - WIKING Maxi 6 with heat store compartment (drawing C) Proceed as follows to change the smoke outlet from top outlet to rear outlet: 1.
Page 13
Hook the cover plate back in place and tighten the two screws. The adjustable feet of WIKING Maxi 2 are on the plinth and the legs, which are delivered along with the wood-burning stove. Mount and adjust the adjustable feet screws in accordance with the separate instructions, 2 in each side, to the desired height.
Page 14
The data plate and the serial number On WIKING Maxi 2, WIKING Maxi 4 with wood store and WIKING Maxi 6 with wood store the data plate is placed on the back of the stove. Page 14 of 24 pages...
Page 15
Norsk On the WIKING Maxi 4 with lower door and WIKING Maxi 6 with lower door the data plate and the serial number are placed on the inside of the lower door. Locate the unique serial number of your wood-burning stove and make a note of it below so that it is always easily accessible.
Page 16
Storage of wood A moisture content of 12-18% is achieved by storing recently felled wood outdoors under a lean- to for at least one year, preferably 2 years. Wood stored indoors has a tendency to become too dry and combust too quickly. However, it might be advantageous to store fuel for lighting a fire indoors for a few days prior to use.
Page 17
the bottom of the stove is covered by embers. Carefully open the door to prevent smoke and embers from escaping. Place 2 pieces of new firewood (up to 1 kg) with a diameter of approx. 5-9 cm in the combustion chamber. When the kindling is burning well, move the air control lever to middle position.
Page 18
Firing in general Rapid or fierce heat Rapid or fierce heat is obtained by burning many small pieces of wood. Maximum amounts of fuel: The maximum allowed amount of fuel per hour is: Wood: 2.74 kg If these limits are exceeded, the stove will no longer be covered by the factory guarantee, and it may also become damaged due to excessive heat, the glass may turn white, for example.
Page 19
Maintenance Cleaning Any maintenance of the stove should only be carried out when it is cold. Daily maintenance is limited to vacuum cleaning the stove externally, using the soft brush attachment. You can also dust the stove using a dry, soft cloth or brush. But remember, only when the stove is cold. Do not use water, spirit or any other kind of cleaner, as this will damage the lacquer.
Page 20
® The spring in the automatism should be checked at least once every second year. WIKING Maxi 2/WIKING Maxi 4: Lift the top plate off the stove. Loosen the screws and remove the back plate. Remove the heatshield. On a cold stove, check the starting point of the arm. The starting point on a cold stove is about 14°...
Page 21
Declaration of Performance The DoP can be downloaded from our website via the following links: www.hwam.com/dop/Maxi Page 21 of 24 pages...
Page 22
Trouble shooting If you experience that your wood-burning stove is not functioning optimally, consult this table to find some usual problems that may arise and how to solve them. If you cannot solve them and/or other problems occur, please contact your maintenance man or WIKING retailer. Problem Possible Cause Try the Following...
Page 23
Product information on solid fuel local space heaters according to Commission regulation (EU) 2015/1185 WIKING Maxi 2, WIKING Maxi 4, WIKING Maxi 6 Model Direct heat output [kW] Indirect heating functionality Indirect heat output [kW] Two or more manual stages, no temperature control...
Page 24
It is important that you record your retailers name, address and telephone number on this section, as he is responsible for any ajustment which may be required during the warranty period. Model type Date of purchase Retailer Address Tel. HWAM A/S DK-8362 HØRNING www.wiking.com...
Need help?
Do you have a question about the wiking Maxi 2 and is the answer not in the manual?
Questions and answers