SELF TESTING MAINTAINED EMERGENCY ILLUMINATION SIGNS WITH WIRELESS COMMUNICATION
TECHNICAL CHARACTERISTICS
Mains voltage
Maximum power consumption
TX/RX FREQUENCY RANGE
TX POWER
Battery (Ni-MH)
Battery protection
Indications
Recharging time
Minimum emergency duration
Light source intensity (230V) / (emerg.)
Degrees of cover protection
Produced in accordance with
Operation temperature range
Relative humidity
Construction materials
Viewing distance
External panel's dimensions
External unit's dimensions
Typical weight
Guarantee
GENERAL
The luminaire consists mainly from two parts,
the body, where all the electronics are located
and the lamp-head where the indication sign
and the high efficiency LEDs are located.
Maintained to non-maintained selection
capability
The operation mode can be selected using the
mode jumper CN4. Depending on the position
of the jumper you can select (M) maintained
operation(this is the default selection) and
(NM) non maintained operation.
Manual Operational Test
The manual test can be conducted only if the
mains power supply and the battery is
connected. By pressing the test button briefly
an operation test is initiated. During this test
period Lamp Fault LED is blinking.
Manual Autonomy Test
A duration test can be conducted if the
luminaire is fully charged and the TEST button
is pressed from 5 to 10 seconds. The luminary
enters emergency mode, the charge LED is
turned OFF and the Battery Fault led starts to
Page 1 from 5
SLD-28/SP/M/WL
2.7W / 3.9VA
100lm /100lm
EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3
280x120x15mm
Thank you for your trust in our products
Olympia Electronics - European manufacturer
(for LED MODULE specifications see page 4)
SLD-34/SP/M/WL
220-240V AC/50-60Hz
868.150-868.450MHz
11dBm
3.6V/1.5Ah
Overcharging and deep discharging protection
Charge LED, Lamp LED, Fault LED, Test Button
EN 62311, ETSI EN 303 446-1 V1.1.0, ETSI EN 300 220-2 V3.1.1
5 to 40 C
up to 95%
ABS/PC, aluminum, Acrylic plate
16m
340x190x15mm
289x65x34mm
720gr.
1040gr.
3 years (1 year for the battery)
blink. The test is conducted until the battery is
depleted.If at the end of the test the autonomy
is low then the Battery Fault LED will stay ON.
If the result of the test is good then the luminary
enters charging mode and the Charge led
starts to blink until the batteries are fully
charged.
Automatic Operational Test
This test includes all the operations that provide
the manual test and is conducted automatically
every 15 days. In order to be performed, the
mains power supply and the battery should be
connected.
Automatic Autonomy Test
The Automatic Autonomous Test is conducted
and measures the luminaire`s back up
operation. This test is conducted automatically
every 6 months. In order to be performed, the
mains power supply and the battery should be
connected (the battery should be charged). If
the battery is not charged, the test is postponed
until the battery is completely charged. If
during the Automatic Autonomous Test the
luminaire's duration is lower than the named,
then the battery must be replaced.
SLD-44/SP/M/WL
3W / 4.2 VA
24h
3h
125lm /125lm
IP30
o
30m
440x240x15mm
1510gr.
922044020_09_001
38m