125 31 35000 Illustrations Illustrations in these instructions for use are intended to provide a basic understanding and may differ from the actual design. Manufacturer's address Manufacturer Philipp Kirsch GmbH Address Im Lossenfeld 14 77731 Willstätt-Sand GERMANY Telephone +49 781 9227-0...
Page 4
E-mail info@kirsch-medical.de Internet www.kirsch-medical.de Orders are accepted during business hours. Further information If you have any questions or comments regarding the device or these instructions for use, please contact your authorised regional dealer or KIRSCH directly. Refrigerator ESSENTIAL LABO-Series 04.12.2024...
1.5 Additional unit components......... 11 1.5.1 Temperature documentation........11 1.5.2 Interior lighting............13 1.5.3 Lockable glass door..........13 Accessories............... 14 2.1 KIRSCH EVOLUTION CLOUD........14 2.1.1 Communication............14 2.1.2 Data backup............. 14 Safety................. 16 3.1 Symbols in this instruction manual......16 3.2 Intended use...............
Page 6
Table of contents 6.2.2.1 Function of the temperature warning limits... 31 6.2.2.2 Displaying and changing the temperature warning limits..............32 Operation................35 7.1 Switching on the unit........... 35 7.2 Switching off the unit........... 35 7.3 Loading the device............36 Cleaning and disinfection..........38 Maintenance..............
Product description Unit overview Product description 1.1 Unit overview Model ESSENTIAL 125 (example) Fig. 1: ESSENTIAL laboratory refrigerator Ä Chapter 1.2 ‘Display and control ele- Display and control unit ments’ on page 8 Door lock Adjustable feet Interior fittings Refrigerating machine (at the rear in the machine compart- ment) 04.12.2024 Refrigerator ESSENTIAL LABO-Series...
Product description Display and control elements > Control details 1.2 Display and control elements 1.2.1 Control details Fig. 2: Display and control unit Please see the following overview for the function of the buttons: Tab. 1: Buttons Posi- Button Designation Function tion –...
Product description Scope of delivery Posi- Button Designation Function tion [ON/OFF] Switch the device on and off. Depending on the version, certain buttons have mul- tiple functions when used in conjunction with other but- tons. Please see the following overview for the function of the display: Tab.
Product description Unit functions > Temperature display 1.4 Unit functions 1.4.1 Cooling Refrigerating machine The device has a refrigerating machine with an internal evaporator to cool the refrigerated goods. After initial commissioning or recommissioning, the refrigerating machine requires some time to cool the interior to the set tempera- ture.
Product description Additional unit components > Temperature documentation 1.4.4 Battery 1.5 Additional unit components The device comes with standard equipment. Additional device components can be added to the standard equip- ment. The following additional components are available for the device: Defrost water receptacle for manual emptying (available for most devices) Alarm in the event of a power failure...
Page 12
Product description Additional unit components > Temperature documentation Tab. 3: Temperature documentation options Designation Function Illustration Cloud module Reliable Alerts by text message and/or e-mail in the event of discrepancies Alarm chain with Holiday function (redirection of the alarm message during absence) Temperature control, possible from any location at any time via smartphone, tablet or PC Additional integrated data storage for up to 30 days...
On devices with a glass door, the interior lighting can be switched on and off permanently using the [Light] button. 1.5.3 Lockable glass door Door lock Your device can be fitted with a lockable glass door. Contact KIRSCH for further information on installing the glass door. 04.12.2024 Refrigerator ESSENTIAL LABO-Series...
The Kirsch EVOLUTION MODULE collects and stores tempera- ture/input data from a device that is to be monitored. By means of mobile internet, the data is sent to the KIRSCH CLOUD. It is done via a special provider-independent IOT SIM card that allows the optimal network coverage.
Page 15
Accessories KIRSCH EVOLUTION CLOUD > Data backup The data is logged at 2 min. intervals on the circular buffer inte- grated into the module. The maximum storage capacity is 30 days. To save the 31st day, the data record of the first day is overwritten.
Safety Symbols in this instruction manual Safety This section provides an overview of all important safety aspects for optimal protection of patients and staff, and for safe and trouble-free operation of the unit. Non-compliance with the instructions and safety warnings in this instruction manual can cause considerable risks.
Safety Foreseeable misuse Other markings Mark Explanation Step-by-step instructions ð Results of actions References to sections in this instruction manual Lists without a specified order References to the instruction manuals for accessories and optional parts 3.2 Intended use The laboratory refrigerator and laboratory freezer are used for the commercial storage of biological and chemical substances.
Safety Residual risksResidual risks 3.4 Residual risks Infection of the user WARNING! Danger of infection due to inadequate hygiene, dis- infection and sterilisation! Contact with parts that have not been cleaned, steri- lised or disinfected poses the danger of infection. –...
Page 19
Safety Residual risksResidual risks Eco cooling machines WARNING! Danger due to unauthorised intervention in the cooling circuit! The cooling machine contains the natural refrigerant propane R290 / isobutane R600a. The refrigerant used in the unit is flammable and can cause serious injury if it comes into contact with the eyes or skin.
Kirsch recommends healthcare organizations or medical institutions to implement a comprehensive and multi-step strategy to protect data and systems from internal and external security threats.
Page 21
(except removable media) are physically safe. CAUTION! Make sure that the refrigerator is only connected to the Kirsch-authorized/approved appliance. Users should operate all Kirsch-provided and supported equipment within Kirsch-authorized specifications, including Kirsch-approved software, software configuration, security configuration, etc. CAUTION! Protect all passwords from unauthorized changes.
Safety Safety labelling 3.6 Safety labelling Rating plate The rating plate contains the following information (information cor- MED 100 PRO-ACTIVE Modell Kühl-Inhalt 95 Liter Type Gross volume responds to the red number): 100 30 35000 - Model Kältemittel Kühl-Aggregat R600a 0,043 kg VKD 2715 K Refrigerant Cooling system...
Safety Personnel qualification 3.7 Personnel qualification Insufficiently qualified personnel WARNING! Danger of damage and injury due to commis- sioning by unqualified staff! If commissioning is performed incorrectly by unqualified staff, serious damage to the chilled goods can result, which in turn can lead to serious injuries. –...
Safety Personal protective equipment 3.8 Personal protective equipment Personal protective equipment is used to protect personnel against hazards that could affect their safety or health at work. Always put on the personal protective equipment required in the various chapters of these instructions before starting the work in question.
Transport and decommissioning Unit transport Transport and decommissioning 4.1 Unit transport When delivered, the device is transported in consultation with the specialist dealer. Observe the following safety instructions when transporting the device to a new location during its service life. Safety during transport WARNING! Danger of crushing injuries from falling unit!
Transport and decommissioning Putting the unit back into operation 4.2 Decommissioning the device Decommissioning the device Hold down the[ON/OFF] button for 3 seconds. Pull out the mains plug. Remove the device key. Leave the device door open to prevent odours and mould from forming.
Overview of installable devices ESSENTIAL 125 Installation The device may only be installed by qualified personnel. If in doubt, Ä ‘Manufacturer's address’ on page 3. contact KIRSCH Install the device as shown in the installation drawing supplied. 04.12.2024 Refrigerator ESSENTIAL LABO-Series...
Set-up, installation and connection Connecting the unit It is necessary to adhere to the specified ventilation cross-sections for supply air and exhaust air. Some models may require installa- tion of the optional refrigerating machine fan. 5.3 Connecting the unit Connecting The unit is designed according to protection class I and protection type IP 20 and is ready to be plugged in.
The set temperature determines the temperature at which the device is operated in order to store the refrigerated goods under optimum conditions. The set temperature of the device is preset by KIRSCH. Changes to the setpoint do not change the temperature Ä Chapter warning limits.
Monitor the temperature progression on the Display or using optional temperature docu- mentation (e.g. KIRSCH-PC-KIT). Read off the current temperature and observe the further temperature curve until the set temperature is reached. Refrigerator ESSENTIAL LABO-Series...
Commissioning Programming the unit > Temperature warning limits Consequences of modified target temperature As soon as the target temperature is reached, the tem- perature warning limits must be adjusted so that the target temperature is above or below the temperature warning limits.
Commissioning Programming the unit > Temperature warning limits 6.2.2.2 Displaying and changing the temperature warning limits Displaying temperature warning limits Upper temperature warning limit Hold down the [Warning limits] button for 4 seconds. ð The LED for the upper temperature warning limit lights up in the display.
Page 33
Commissioning Programming the unit > Temperature warning limits Changing temperature warning limits Recommended temperature warning limits The temperature warning limits must not be the same as the target temperature. Set the temperature limits as follows: – Upper temperature warning limit: at least 3 °C higher than the target temperature –...
Page 34
Commissioning Programming the unit > Temperature warning limits Press and hold the [Set temperature] button. ð The upper temperature warning limit is shown in the Dis- play. The upper warning limit can be set using the [Down] and [Up] buttons. Press the [Warning limits] button again to exit programming mode.
Operation Switching off the unit Operation Personnel: User 7.1 Switching on the unit Hold down the[ON/OFF] button for 3 seconds. Check the set temperature or adjust if necessary Ä Chapter 6.2.1.2 ‘Displaying and changing the target temperature’ on page 30. Lead time of the temperature alarm! The temperature alarm is active at the earliest when the target temperature is reached, and at...
Operation Loading the device 7.3 Loading the device CAUTION! Danger to chilled goods due to contamination! A dirty unit can contaminate the stored chilled goods. A contamination can damage or destroy the chilled goods. – Do not store contaminated chilled goods in the unit. –...
Page 37
Load the device with refrigerated goods. If the door is open for more than 60 seconds, deactivate the Door Open alarm if necessary. A suitable temperature measuring device, e.g. Kirsch Evolution Cloud, should be used to check the tempera- ture.
If disinfectants other than those referred to are used, test them for compatibility on an inconspicuous area before using them for the first time. Only use acid-free disinfectants. If in doubt, contact KIRSCH. Cleaning and disinfecting the device Protective equipment:...
Page 39
Cleaning and disinfection CAUTION! Danger of damage due to interrupted cooling chain during stock transfer! If the cooling chain of the chilled goods is interrupted by a stock transfer, the prescribed storage conditions are no longer met. This can damage the chilled goods. –...
Maintenance Safety inspection Maintenance Interval Maintenance work at least every 24 months Perform a safety inspection in accordance with DGUV regulation 3 (for- merly BGV A3). at least every 6 months Check the condenser Ä Chapter 9.1 ‘Safety inspection’ on page 40. 9.1 Safety inspection Perform safety inspection every two years! The unit should be inspected by the owner in line with...
Page 41
Maintenance Safety inspection Checking the temperature Tool: Calibrated temperature measuring device Create a simulation of chilled goods for the sensor. Attach measuring sensor in the interior at medium height. Read temperature after 120 minutes. Ä Chapter 8 After the check, clean and disinfect the unit ‘Cleaning and disinfection’...
Alarms Dealing with alarms Alarms 10.1 Alarm functions Alarm functions An alarm is triggered if a device function is faulty or defective. Every alarm is signalled both visually and audibly. The display alternately shows the visual alarm and the tempera- ture.
Page 43
Alarms Dealing with alarms Acknowledging the alarm The buzzer is deactivated, the cause of the alarm is eliminated, but the alarm is still shown on the display. Press the [Up] or [Down] button. ð The alarm is acknowledged. The display shows the tem- perature of the refrigerated goods.
(e.g. electric shocks) and damage (e.g. fire, damage to chilled goods). – Have repairs performed by the service department. – Use KIRSCH replacement parts. – Do not make independent additions or changes to the unit. – If in doubt, contact KIRSCH. Refrigerator ESSENTIAL LABO-Series 04.12.2024...
Page 45
Status displays and error messages Error messages Moving refrigerated goods NOTICE! Danger to chilled goods due to defective or faulty unit! A defect or fault in the unit means that its cooling per- formance is no longer ensured. Reduced cooling per- formance can cause considerable damage to chilled goods.
Page 46
NOTICE! For repairs, contact the service department: The following company is appointed and authorised by Ä ‘Service con- KIRSCH to provide service for the unit: tact’ on page 4 CAUTION! Danger of damage due to interrupted cooling chain during stock transfer!
Decommissioning and disposal Disposing of the device Decommissioning and disposal 12.1 Decommissioning the device Decommissioning Switch off the device. Move refrigerated goods. Pull out the mains plug. Cut the connection cable. Remove or destroy the locks. Remove the door. 12.2 Disposing of the device Disposing of the device ENVIRONMENT!
Appendix Appendix Depending on the model, the following applicable documents can be found in the appendix: Declaration of Conformity Technical data Installation drawing Refrigerator ESSENTIAL LABO-Series 04.12.2024...
Declaration of Conformity 13.1 Declaration of Conformity EG-Konformitätserklärung Wir, Philipp Kirsch GmbH Im Lossenfeld 14 77731 Willstätt-Sand Deutschland erklären hiermit in alleiniger Verantwortung, dass die nachfolgend beschriebenen Produkte zum Zeitpunkt des Inverkehrbringens die Schutzanforderungen der unten genannten Richtlinien und Normen einhalten.
Need help?
Do you have a question about the ESSENTIAL LABO Series and is the answer not in the manual?
Questions and answers