Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Tektronix Manuals
Analytical Instruments
7B10
Instruction manual
Tektronix 7B10 Instruction Manual page 54
Time base
Hide thumbs
Also See for 7B10
:
Instruction manual
(26 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
page
of
118
Go
/
118
Bookmarks
Advertisement
Calibration
7B10
TABLE
5-1
(CONT.)
Performance
Check
Summary
Characteristic
Performance Requirement
Performance
Check
Procedure
Title
Adjustment and
Performance
Check
Procedure
Title
Sweep
Accuracy
(cont.)
0°
to
+50°
C
Derate
+1
5°
to
+35°
C
accuracy
by
additional
1%.
Customer
verification
normally
not required.
Sweep
Length
At
least
10.2
div.
B2.
Check
Sweep
Length and
Position-
ing
Range.
B2.
Check
Sweep
Length
and
Position-
ing
Range
MAG
Registration
0
5
div or less
from
graticule
center
when
changing from
MAG
XI
0
to
MAG
XI.
B3.
Check
Magnifier
Gain and
Registration.
B3.
Check/Adjust
Magnifier
Gain and
Registration.
Position
Range
POSITION
Controls
fully
CW
Start
of
sweep must
be
to right
of
graticule
center
at
1
ms/div.
j
B2,
Check
Sweep
Length and
Position-
ing
Range.
B2.
Check
Sweep
Length
and
Position-
ing
Range.
POSITION
Controls
fully
CCW
End
of
sweep
must
be
left
of
'
graticule
center
at
1
ms/div.
TRIGGERING
SYSTEM
Trigger
Sensitivity
for
Repetitive
Signals
Triggering
Frequency
Range®
Minimum
Triggering
Signal
Required
Coupling
Internal
External
AC
30
Hz
to
250
MHz
0.5
div
50
mV
250
MHz
to
1
GHz
1
.5
div
150
mV
AC
LF
REJ"*
50
kHz
to
250
MHz
0.5
div
50
mV
250
MHz
to
1
GHz
1
.5
div
150
mV
AC
HF REJ
30
Hz
to
30
kHz
0.5
div
50
mV
DC®
Dc
to
250
MHz
0.5
div
50
mV
250
MHz
to
1
GHz
1
.5
div
150
mV
A4.
Check
External
Triggering
Sensitivity.
A5.
Check
Internal
Triggering
Sensitivity
A2. Adjust
External
Trigger
Compensation
(Cl
17).
A3. Adjust
Sensitivitiy
(R147).
'The
triggering
frequency ranges
given here
are limited to the -3
dB
frequency
of
the oscilloscope
vertical
system
when
operating
in
the
Internal
mode,
^ill
not
trigger
on
sine
waves
at or
below
60
Hz
when
amplitudes
are
less
than 8
divisions Internal or
3
volts External.
^The
Triggering
Frequency
for
DC COUPLING
applies
to
frequencies
above
30 Hz
when
operating
in
the
AUTO
TRIGGERING MODE.
5-3
Previous
Page
Next
Page
1
...
51
52
53
54
55
56
57
58
Advertisement
Need help?
Do you have a question about the 7B10 and is the answer not in the manual?
Ask a question
Go to Questions and Answers
Subscribe to Our Youtube Channel
Related Manuals for Tektronix 7B10
Test Equipment Tektronix 7B10 Instruction Manual
Time base (26 pages)
Analytical Instruments Tektronix 7B53A Instruction Manual
Dual time base operators (32 pages)
Analytical Instruments Tektronix MSO70000 Series Instructions Manual
Mixed signal oscilloscopes, digital serial analyzers, digital phosphor oscilloscopes, digital phosphor oscilloscopes declassification and security (26 pages)
Analytical Instruments Tektronix TCP0030A Instruction Manual
120 mhz, 30 amp ac/dc current probe (92 pages)
Analytical Instruments Tektronix TDS7000 Series Online Programmer Manual
Digital phosphor oscilloscopes/communication signal analyzers (876 pages)
Analytical Instruments Tektronix 570 Instruction Manual
Characteristic-curve tracer (59 pages)
Analytical Instruments Tektronix TMSST2 Instruction Manual
Socket hardware support (50 pages)
Related Products for Tektronix 7B10
Tektronix 7B70
Tektronix 7B53N
Tektronix 7B51
Tektronix 7603
Tektronix 71310
Tektronix 7S12
Tektronix 7140
Tektronix 7854
Tektronix 7313/R7313
Tektronix 7904
Tektronix 7CT1N
Tektronix 7M13
Tektronix 7623A
Tektronix 7844
Tektronix 7612D
Tektronix 791AD
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the 7B10 and is the answer not in the manual?