Acromag AVME9670 User Manual

Industrial i/o pack vme64x bus 6u non-intelligent carrier board

Advertisement

Quick Links

Acromag AVME9670
VME IndustryPack Carrier Module
A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
In Stock
Used and in Excellent Condition
Open Web Page
https://www.artisantg.com/72797-1
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVME9670 and is the answer not in the manual?

Questions and answers

Summary of Contents for Acromag AVME9670

  • Page 1 Acromag AVME9670 VME IndustryPack Carrier Module In Stock Used and in Excellent Condition Open Web Page https://www.artisantg.com/72797-1 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
  • Page 2 Wixom, MI 48393-7037 U.S.A. Tel: (248) 624-1541 Fax: (248) 624-9234 Copyright 2000, Acromag, Inc., Printed in the USA. Data and specifications are subject to change without notice. 8500-628-C01D003 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3: General Information

    ___________________________________________________________________________________________ The information contained in this manual is subject to change Power Supply Fuses............without notice. Acromag, Inc. makes no warranty of any kind with 5.0 SERVICE AND REPAIR............ regard to this material, including, but not limited to, the implied SERVICE AND REPAIR ASSISTANCE......
  • Page 4: Signal Interface Products

    • Individually Filtered Power - Filtered +5V, +12V, and -12V other end. The cable is used for connecting AVME9670 or DC power is provided to the IP modules via passive filters AVME9675 with the TRANS-200, or other compatible carrier present on each supply line serving each IP.
  • Page 5: Preparation For Use

    SCSI-2 to Flat Ribbon Cable, Shielded (Model 5028-187) to consideration should be given to air-filtering. the rear of the card cage, and to AVME9670, AVME9675-2 & AVME9675-4 boards within the card cage. BOARD CONFIGURATION The carrier board may be configured for different applications.
  • Page 6 The TRANS-200 was originally designed for use with the Register (BAR). The host computer can locate the AVME9675 by AVME9670 product which supports four IP modules A-D. It also scanning the A24 CR/CSR space using address modifier 2FH (refer may be used for the four IP slot AVME9675-4 or the two slot to section 3 for CR/CSR space programming details).
  • Page 7 INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ Pin assignments for these connectors are defined by the IP DTACK* +3.3V module specification and are shown in Table 2.2: GA4* RsvBus +3.3V Table 2.2: Standard IP Logic Interface Connections (P4,6,8,10) RsvBus RsvBus IACK*...
  • Page 8: Data Transfer Timing

    This is particularly important for analog I/O applications when a high level of accuracy/resolution is needed (12- bits or more). Contact your Acromag representative for information on our many isolated signal conditioning products that could be used to interface to the IP input/output modules.
  • Page 9 4 bytes AVME9675 Board ID 0x00,00,00,01 to 10 of the Address DEcoder Mask (ADEM) are set and indicate 0x33,0x37,0x3B,0x3F supplied by Acromag that address bits A15, A14, A13, A12, A11, and A10 are compared 4 bytes AVME9675 Revision ID 0x00,…,00 for decoding purposes.
  • Page 10 INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ been programmed, the “Module Enable” bit defined within the Bit Set access method and utilizes only every fourth byte. All / Bit Clear CSRs is used to enable the AVME9675. The AVME9675 unimplemented locations in the defined CSR area will be read as will then respond to its defined address space as initialized by 0x0.
  • Page 11 INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ Table 3.3A: AVME9675 6U Carrier Bd Short I/O Memory Map Table 3.3B: AVME9675 Carrier Board Registers Base Base Base Base Address + EVEN Byte ODD Byte Address + Address + EVEN Byte ODD Byte Address +...
  • Page 12 This bit when set to “1” indicates that the Timed Out Access last IP module has timed out (The IP did not acknowledge the access.) This bit Acromag ID will be “0” on power-up. Reading the Code carrier board status register will clear this IP Model Code bit to “0”.
  • Page 13 INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ Where: Bits 7, 6, 5, 4 Not used - equal "0" if read. Bit 3 Writing a "1" to this bit enables the memory IP-D Memory Enable space for IP D. A zero disables memory Used Used Used...
  • Page 14: General Programming Considerations

    INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ IP Interrupt Enable Register - (Read/Write, Base + E1H) GENERAL PROGRAMMING CONSIDERATIONS The IP Interrupt Enable Register is used to individually The carrier board register architecture makes the configuration enable/disable IP interrupts. Each IP A through D may have up to fast and easy.
  • Page 15: Theory Of Operation

    The TRANS-200 was originally designed for use with the 2. The AVME9675 carrier board acts as an interrupter in making AVME9670 product which supports four IP modules A-D. It is the VME64x bus interrupt request (asserts IRQx*) also compatible with the AVME9675-4 (IP slots A-D) and corresponding to the IP interrupt request.
  • Page 16 INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ Carrier Board Registers Carrier Board Clock Circuitry The carrier board registers (presented in section 3) are Separate 8MHz IP clocks are driven to each IP module. All implemented in the logic of the carrier board’s FPGA. An outline of clock lines include series damping resistors to reduce clock the functions provided by the carrier board registers includes: overshoot and undershoot, and similar length PC board trace...
  • Page 17: Service And Repair Assistance

    It is highly recommended that a non-functioning An active IACKIN* signal, detected by the carrier board, is either board be returned to Acromag for repair. The board can be passed to Interrupt Acknowledge Output (IACKOUT*) or consumed by the carrier board.
  • Page 18: Industrial I/O Pack Compliance

    INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ VME64x bus Address Modifier Codes: Level II. P0 (VME64x bus)....... J3 Type B, Right-Angle Short I/O (A16) Space....Base address is relocatible with Female 95-contacts, with selection in CR/CSR space. upper ground shield.
  • Page 19 INDUSTRIAL I/O PACK SERIES AVME9675 VME64x 6U CARRIER BOARD ___________________________________________________________________________________________ Interrupts........Supports two interrupt requests per IP and interrupt acknowledge cycles, D16/D08(O). Access LED (Illuminate duration)....0.125 second, typical ENVIRONMENTAL Operating Temperature....0 to +70°C. -40 to +85°C (E versions) Note that visual LED performance May be degraded below -20°C.
  • Page 20 Shipping Weight: 1.25 pounds (0.6kg) packed. the TRANS-200 Transition Module. The transition module then connects to all four IP module slots to the rear of the AVME9670 or AVME9675-4 (Slots A-D). The AVME9675-2 uses IP slots VME64x TRANSITION MODULE: MODEL TRANS-200 A-B.
  • Page 21 4501-800A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22 4501-801A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23 4501-802A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 25 4501-464A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 26 4501-760B Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...

Table of Contents