www.pulsar.pl
Ripple voltage
Current consumption by PSU systems
Battery charging current
Short-circuit protection SCP
Overload protection OLP
Battery circuit protection SCP and reverse
polarity connection
Surge protection
Overvoltage protection OVP
Deep discharge battery protection UVP
Tamper protection:
TAMPER - indicates unwanted opening of the
-
enclosure
Technical outputs:
- EPS; output indicating AC power failure
- PSU; output indicating no DC power/PSU failure
- LoB output indicating low battery voltage
LED indication
Acoustic indication
Fuses:
- F
MAINS
- F
BAT
Table 4. Mechanical specifications
Enclosure dimensions
Fixing
Fitting battery
Net/gross weight
Enclosure
Closing
Terminals
Notes
Table 5. Operation safety
Protection class PN-EN 60950-1:2007
Degree of Protection PN-EN 60529: 2002 (U)
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
Insulation resistance:
- between input circuit and output or protection circuit
.
200 x 230 x 80+8 mm (Fig.3) WxHxD
See Fig., 3
7Ah/12V (SLA) max.
165x100x75mm (WxHxD) max
1,9 / 2 kg
Steel plate DC01, thickness: 0,7mm, colour: RAL 9003
Cheese head screw (at the front)
Mains supply 230V AC: Ф0,51÷2,05 (AWG 24-12), 0,5÷1,5mm
Outputs: Ф0,51÷2,05 (AWG 24-12), 0,5÷1,5mm
BAT battery outputs: 6,3F-0,5, 19cm
The enclosure does not adjoin the assembly surface so that cables can be led.
.
AWZ110
20mV p-p
15 mA max.
0,4A
200% ÷ 250% of PSU power - current limitation and/or fuse
damage in the battery circuit (fuse-element replacement
F
BAT
required )
Automatic return
110% ÷ 150% (@25ºC÷65ºC) of PSU power - limitation by the
PTC resettable fuse, manual restart (disconnection of the DC
output circuit)
F2A-
current limitation, F
element replacement required)
varistors
disconnection
U>16,5V
disconnection),
automatic return
fault indication
U> 14,5V
U<10V (± 0,5V) – disconnection of battery terminal
microswitch, NC contacts (enclosure closed ), 0,5A@50V DC
-
(max.)
- OC type: 50mA max.
Normal operation: L state (0V),
failure: hi-Z state,
- delay time 0s÷6h (+/-20%) – jumper selectable T
- OC type: 50mA max.
Normal operation: L state (0V),
failure: hi-Z state,
- OC type, 50mA max.
Normal operation (
failure (
U
<11,5V): hi-Z state
BAT
LEDs: AC/DC power status, failure
piezoelectric indicator 75dB/0,3m, switchable via jumper
T 315mA / 250V
F 2A / 250V
H
D
6
GREY POWER plus
fuse (in case of a failure, fuse-
BAT
of
the
output
voltage
AC
U
>11,5V): L state (0V),
BAT
W
2
2
first )
I (
IP20
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
100 MΩ, 500V/DC
(AUX+
Need help?