Section 9
Disassembly
Remove Outer Baffles and Blower
Housing
1. Disconnect the wire leads from the start switch
on the blower housing (if so equipped).
Disconnect the plug from the rectifier-regulator.
Use the tip of the dipstick or a similar small flat
tool to bend the locking tang, then remove the B+
terminal from the center position in the plug. See
Figure 9-26. This will allow the blower housing to
be removed without disturbing the wiring
harness.
Figure 9-26. Disconnecting Plug from Rectifier-
Regulator.
2. The rectifier-regulator does not have to be
detached from the blower housing. If the engine
is equipped with SMART-SPARK
mounting screws from the spark advance module
(SAM). See Figure 9-27. The module will hang
loose as part of the wiring harness.
3. Remove the three (each side) hex flange screws
securing the outer baffles. Note the location of
any lifting strap and the position of the two short
screws (one each side on bottom) for reassembly.
See Figure 9-28.
9.8
Figure 9-27. Loosening Spark Advance Module
(Applicable Models).
Figure 9-28. Note Location of Short Screws.
, remove the
4. Remove the outer baffles. See Figure 9-29.
Figure 9-29. Removing Outer Baffles.
5. If the flywheel screen overlaps the blower
Short
Screw
housing, remove the fasteners and screen. If it
was a metal screen with long bolts, also remove
the remaining loose hardware and cooling fan.
See Figure 9-30.