Kohler Command CV17-750 Service Manual page 160

Vertical crankshaft
Hide thumbs Also See for Command CV17-750:
Table of Contents

Advertisement

Section 9
Disassembly
Heavy Duty Air Cleaner
1. Disconnect the breather hose from the fitting in
adapter or elbow. Remove the hex flange nuts
securing the adapter and any attached clips to the
mounting studs. See Figure 9-10.
Adapter Elbow
Breather
Hose
Figure 9-10. Removing Breather Hose, Hex Nuts
and Adapter Elbow (Two-Barrel Model Pictured).
2. Pull the adapter elbow and gasket off the
mounting studs.
3. Remove the four screws (inner two valve cover
screws on each side) securing the air cleaner main
support bracket. Do not lose any of the mounting
hardware.
Two-Barrel Carburetor Models only: Unhook the
choke return spring from the bottom of the air
cleaner mounting bracket. See Figure 9-11.
Main Bracket Mounting Screws
Figure 9-11. Air Cleaner Bracket/Valve Cover
Mounting Screws (Two-Barrel Model Pictured).
9.4
Hex
Nuts
Choke Return Spring
4. Remove the two upper screws securing the air
cleaner mounting bracket to the blower housing
and remove the air cleaner assembly. See Figures
9-12 and 9-13.
Figure 9-12. Removing Upper Mounting Screws.
Figure 9-13. Removing Heavy Duty Air Cleaner
Assembly (Two-Barrel Model Pictured).
Remove Control Panel (If So Equipped)
1. Disconnect the Oil Sentry™ Indicator Light wires.
2. Disconnect the choke control cable from the
throttle control bracket.
3. Disconnect the throttle control bracket from the
cylinder head. See Figure 9-14.
4. Remove the panel from the blower housing. See
Figure 9-15.
Upper Mounting Screws