Kohler Command CV17-750 Service Manual page 113

Vertical crankshaft
Hide thumbs Also See for Command CV17-750:
Table of Contents

Advertisement

WARNING: Spring Under Tension!
Retractable starters contain a powerful, recoil spring that is under tension. Always wear safety goggles when servicing retractable
starters and carefully follow instructions in this section for relieving spring tension.
Hex
Flange
Screws
Spring and
Keeper
Pulley
Brake Washer
Brake Spring
Center Screw
Figure 7-1. Retractable Starter – Exploded View.
To Remove Starter
1. Remove the five hex flange screws securing the
starter to the blower housing.
2. Remove the starter.
To Install Starter
1. Install the retractable starter onto the blower
housing leaving the five hex flange screws
slightly loose.
Section 7
Retractable Starter
Starter Housing
Handle with
Rope Retainer
Rope
Pawl Springs
Pawls
Pawl Retainer
Plain Washer
Drive Cup
2. Pull the starter handle out until the pawls
engage in the drive cup. Hold the handle in this
position and tighten the screws securely.
Rope Replacement
The rope can be replaced without complete starter
disassembly.
1. Remove the starter from the blower housing.
2. Pull the rope out approximately 12 in. and tie a
temporary (slip) knot in it to keep it from
retracting into the starter. See Figure 7-2.
Slipknot
Figure 7-2. Removing Starter Handle.
3. Remove the rope retainer from inside the starter
handle. Untie the single knot and remove the
rope retainer and handle.
4. Hold the pulley firmly and untie the slipknot.
Allow the pulley to rotate slowly as the spring
tension is released.
5. When all spring tension on the starter pulley is
released, remove the rope from the pulley.
Section 7
Retractable Starter
Handle
Knot
Rope Retainer
7.1
7

Advertisement

Table of Contents
loading