ADVANTAGE 3100 Full Face Mask Volgelaatsmasker met with Standard Thread Connector schroefdraadaansluiting Цяла лицева маска със стандартно DE Vollmaske mit Rundgewindeanschluss присъединяване на резба Celoobličejová maska se standardním FR Vollmaske mit Rundgewindeanschluss závitovým připojením Maschera a pieno facciale Zsinórmenetes légzéscsatlakozóval con filettatura standard ellátott teljesálarc...
Page 2
The warranties made by MSA with respect to the be treated with an antistatic spray, or a water product are voided if the product is not used and screen must be used.
Design, Operation and Use of Fig. 1 Full Face Mask (see front page) The inhalation air flows from the connector of the mask past the inhalation valve to the inside of the lens (thus keeping the lens largely fog-free) and then into the nose cup.
Part of the visual test is to ensure adherence to the test intervals according to Sect. 5. Fig. 5 Leak Test The leak test is performed with the MSA leak test kit; its operation is described in the kit’s Instruction Manual. The MSA Customer Service should be consulted prior to using leak test kits of other manu- facturers.