MSA 3S-H/F1 Operating Manual
MSA 3S-H/F1 Operating Manual

MSA 3S-H/F1 Operating Manual

Mask-negative pressure, mask/helmet combination

Advertisement

Quick Links

Operating Manual
3S-H Mask – Negative Pressure
Mask/Helmet Combination 3S-H/F1
Order No.:
10110541/04
MSAsafety.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3S-H/F1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MSA 3S-H/F1

  • Page 1 Operating Manual 3S-H Mask – Negative Pressure Mask/Helmet Combination 3S-H/F1 Order No.: 10110541/04 MSAsafety.com...
  • Page 2 MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland info.ch@MSAsafety.com www.MSAsafety.com © MSA 2022, 2018 All rights reserved...
  • Page 3: Table Of Contents

    Contents Safety Regulations ..........5 Correct Use.
  • Page 4 Applicable Helmets ......... . 23 MSA Gallet F1 Helmets ........23 MSA Gallet F2 X-TREM Helmets .
  • Page 5: Safety Regulations

    Before use the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used.
  • Page 6: Liability Information

    MSA or authorized persons. Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator.
  • Page 7: Description

    Description Description The face blank is made of a special soft rubber compound and assures a snug, comfortable fit and a tight seal. Some versions of the mask are also available in small size. The inhalation air flows from the connector of the mask past the inhalation valve to the inside of the lens [thus keeping the lens largely fog-free] and then through the check valves into the nose cup.
  • Page 8: Mask Versions

    Description Mask Versions MSA 3S-H • Standard version with polycarbonate lens MSA 3S-H small • as standard version, small size MSA 3S-H-V • as standard version, with polycarbonate lens with silicate coating MSA 3S-H-Vg • as standard version, with Triplex [laminated] glass...
  • Page 9: Certification

    Description Certification Mask with Lenses from Polycarbonate with Silicate Coating The masks according to chapter 2.1 comply with the following directives, standards or standardised documents: Directive 2014/34/EU [ATEX] : BVS 05 ATEX H 027 X for masks I M1 II 1 G IIA T6 -40 °C  Ta  +60 °C II 1 D for helmets F1SF and F1E: I M1...
  • Page 10 Description Mask with Lenses from Polycarbonate The masks according to chapter 2.1 comply with the following directives, standards or standardised documents: Directive 2014/34/EU [ATEX] : BVS 05 ATEX H 027 X for masks I M1 II 1 G IIA T6 -40 °C  Ta  +60 °C II 1 D I M1 II 1 G IIB T6 -40 °C ...
  • Page 11 Description Mask with Lenses from Triplex [laminated] Glass The masks according to chapter 2.1 comply with the following directives, standards or standardised documents: Directive 2014/34/EU [ATEX] : BVS 05 ATEX H 027 X for masks I M1 II 1 G IIA T6 -40 °C  Ta  +60 °C II 1 D I M1 II 1 G IIB T6 -40 °C ...
  • Page 12: Use

    The mask is either carried using the harness in front of the chest or in the mask container. WARNING! only Ensure that the top of the mask seal lies on the user's forehead. Hair should not be between the mask's seal and the user’s skin. The mask could otherwise leak.
  • Page 13: Donning The Mask

    Donning the Mask WARNING! must In order to guarantee a proper fit for those wearing glasses, the 3S-H Mask spectacle kit be worn cannot since ordinary glasses be worn under the mask. When fitting the mask in position the chin strap of the helmet must be loose. Remove chin piece if necessary.
  • Page 14: Leak Check

    Leak Check In order to check the mask-to-face tightness a leak test must be performed before each use. Seal the mask connector or the inlet opening side of an attached filter with the ball of your hand. Test tightness by inhaling and exhaling. Whilst doing so: when inhaling there must be negative pressure, no inflowing air should be noticeable.
  • Page 15: Cleaning, Disinfection

    Cleaning, Disinfection Cleaning, Disinfection The cleaning and disinfection of the masks is performed in accordance with the cleaning intervals  chapter 5.2. There are three possible kinds of cleaning: • Using a washing machine • disk washing type (Meiko) • tumbling type (Miele) •...
  • Page 16: Cleaning By Hand

    Cleaning, Disinfection Cleaning by Hand Remove inhalation and exhalation valve discs. Unbutton the nose cup. Unscrew the speaking diaphragm with the special tool. Clean mask using lukewarm water and mild cleaning agent EW 80 and thoroughly rinse in running water. Disinfect the mask after cleaning.
  • Page 17: Maintenance

    Always use original parts from MSA. Repairs and maintenance must be carried out only by authorised service centres or by MSA. Changes to devices or components are not permitted and will result in loss of approval.
  • Page 18: Maintenance Of The Exhalation Valve

    Maintenance Maintenance of the Exhalation Valve The year of manufacture is located on the valve disc. In case of a leak remove the exhalation valve disc and replace it with a new one as follows: Remove the protective housing. Remove the exhalation valve disc or remove exhalation valve.
  • Page 19: Tightness Test Of The Mask

    For the safekeeping of the mask the mask container should be used. This also applies to masks with installed filters, except CO and NO filters. MSA rubber products are protected by an anti-aging agent that can become visible as a light coating. This coating is harmless and can be removed during cleaning.
  • Page 20: Ordering Information

    Ordering Information Ordering Information Exploded View Fig. 3 Mask exploded view Nose cup valve seat Protective housing Nose cup valve disc Inhalation valve seat Nose cup [without valves] Inhalation valve disc Retainer ring Lens ring Speech diaphragm Lens Carrying strap Adapter with tightening strap Threaded ring valve socket Lens ring...
  • Page 21: Mask

    [for replacing exhalation valve and speech diaphragm] Exhalation valve closure D5135047-SP Mask hanger [package of 4] D2055753 Mask tightness test kit D6063705 [for more MSA testing instruments refer to www.MSAsafety.com] Advantage container 10026179 Test plate D6125721 Test band D6125715 3S-H Mask – Negative Pressure...
  • Page 22: Replacement Parts

    Ordering Information Replacement Parts Description Article No. Maintenance Set D2055999 [inhalation valve, exhalation valve, valve seat, 2 nose cup valve discs] Nose Cup, without valves [rubber] D2055025-SP Lens [polycarbonate, package of 10] 10080822 Lens [polycarbonate with silicate coating] D2055757 Lens [laminated glass] D2055730 Lens ring, assembly D2055746...
  • Page 23: Applicable Helmets

    Applicable Helmets Applicable Helmets MSA Gallet F1 Helmets Helmets Colour of the shell F1 SF* [EN 443:2008] F1 E* [EN 443:2008] red* yellow* blue* black* white* orange* green luminescing* F1 E [EN 443:2008] F1 SF [EN 443:2008] nickel * The mask/helmet combination with neck curtain for which all helmet compo-...
  • Page 24: Msa Gallet F2 X-Trem Helmets

    Applicable Helmets MSA Gallet F2 X-TREM Helmets Helmets Colour of the shell INDUSTRY [EN397] -unvented shell -no chinstrap GA3200-BA00 White Optional: 2-point chinstrap WILDLAND RESCUE [EN12492] -Vented shell -3-point chinstrap GA33xx White Blue Yellow Black Grey Orange Green Photoluminescent Optional:...
  • Page 25 Applicable Helmets 3S-H Mask – Negative Pressure...
  • Page 26 For local MSA contacts, please visit us at MSAsafety.com Because every life has a purpose...