Page 1
www.larius.com Airless electric diaphragam pump Dalì DALÍ suction system LAK18957/1 - motor 220V - fitting 1/4" - 220bar + hose + gun DALÍ suction system LA18900/1 - motor 220V - fitting 1/4" - 220bar DALÍ suction system LAK18958/1 - motor 110V - fitting 1/4" - 220bar + hose + gun DALÍ...
Page 2
DALI' This manual is to be considered as an English language translation of the original manual in Italian. The manufacturer shall bear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian. Due to a constant product improvement programme, the factory reserves the right to modify technical details mentioned in this manual without prior notice.
Page 3
WE ADVISE THE USE OF THIS EQUIPMENT ONLY BY PROFESSIONAL OPERATORS. ONLY USE THIS MACHINE FOR USAGE SPECIFICALLY MENTIONED IN THIS MANUAL. Thank you for choosing a SAMOA. product. As well as the product purchased, you will receive a range of support services enabling you to achieve the results desired, quickly and professionally.
Page 4
DALI' WARNINGS The table below provides the meaning of the symbols used in this manual in relation to using, earthing, operating, maintaining, and repairing of this equipment. • Read this operator’s manual carefully before using the equipment. • An improper use of this machine can cause injuries to people or things. •...
DALI' TRANSPORT AND SAFETY RULES UNPACKING • THE EMPLOYER SHALL TRAIN ITS EMPLOYEES ABOUT • The packed parts should be handled as indicated in the ALL THOSE RISKS STEMMING FROM ACCIDENTS, ABOUT symbols and markings on the outside of the packing. THE USE OF SAFETY DEVICES FOR THEIR OWN SAFE- TY AND ABOUT THE GENERAL RULES FOR ACCIDENT •...
DALI' ELECTRICAL SAFETY PRECAUTIONS • NEVER MODIFY ANY PART IN THE EQUIPMENT. CHECK REGULARLY THE COMPONENTS OF THE SYSTEM. REPLACE THE PARTS DAMAGED OR WORN. • Check the "ON/OFF" switch is on the "OFF" position before connecting the cable to the mains. •...
DALI' WORKING PRINCIPLE The DALÍ unit is defined as an “electric diaphragm pump”. An ates a vacuum. The product is sucked up, pushed towards the electric diaphragm pump is used for high pressure paint spraying pump outlet and sent to the guns through the flexible hose . A without air (known as “airless”).
DALI' DESCRIPTION OF THE EQUIPMENT Fig. 1 Pos. Description Pos. Description LARIUS AT 250 gun Suction tube High pressure feed tube Colour body Carriage Hydraulic body Electric / combustion motor Recirculation valve Hydraulic oil filling cap Feed tube connection Setting valve Recirculation pipe connection Manometer Product suction tube connection...
Page 9
DALI' SETTING-UP HOSE AND GUN CONNECTIONS • Connect the high pressure flexible hose to the pump and to the gun, ensuring to tighten the fittings (the use of two wrenches is suggested). • It is recommended to use the hose provided with the standard kit (ref.
DALI' • Point the gun at a container keeping the trigger pressed (so as to drain the oil inside) till a clean solvent comes out. Now, Fig. 6 WASHING OF THE NEW EQUIPMENT Fig. 9 • The equipment has already been adjusted at our factory with light mineral oil left inside the pumping group as protection.
DALI' WORKING Fig. 1 START OF THE PAINTING OPERATIONS the idle speed. Use the tooling after performing all the SETTING UP ope- • rations above described. • Make sure the product recycles from the return tube (I4). • Dip the suction pipe (1) into the product tank. •...
Page 12
DALI' CLEANING AT THE END WORK • Reduce pressure to the minimum (turn counterclockwise the pressure control knob (1) ). Fig. 2 Fig. 1 • Press the ON/OFF switch (2) placed on the box of the electric motor, to stop the equipment. •...
DALI' ROUTINE MAINTENANCE specific solvents depending on the type of paint used and refit all parts by inverting the removal order. TOP UP HYDRAULIC OIL With each start up, check the hydraulic oil level by looking through the gauge (1) on the side of the hydraulic body. If necessary, use to top up the level: AGIP DICREA 150 type hidraulic oil Fig.
Page 14
DALI' Fig. 5 Fig. 7 Fig. 6 CLEANING THE MOTOR COOLING FAN GUARD Clean the motor cooling fan protection guard (K6) periodically to ensure the best cooling. Fig. 8 WARNING PLATE Fig. 1 ED. 17 - 11/2024 - Cod. 150101...
Page 15
DALI' CORRECT PROCEDURE OF DECOMPRESSION • Insert the gun clamp (1). • Move the ON/OFF switch (2) to the OFF position to stop the equipment. • Set the valve (3) at its minimum pressure setting (turn counterclockwise). Fig. 1 Fig. 2 Fig.
DALI' PROBLEMS AND SOLUTIONS Problem Cause Solution The equipment does not start Lack of voltage; Check the correct connection to the power supply; Considerable drops in mains voltage; Check the extension cable; ON-OFF switch disconnected; Ensure the ON-OFF switch is on the “ON”...
DALI' COMPLETE COLOUR BODY WARNING: always indicate code and quantity for each part required. VERTICAL VERSION Fig. 1 ED. 17 - 11/2024 - Cod. 150101...
DALI' SUCTION SYSTEM WARNING: always indicate code and quantity for each part required. Fig. 1 Pos. Code Description LA85009 Suction systems LA85010 Suction tube LA16609 Recirculation tube LA18096 Spring LA85012 Filter of suction ED. 17 - 11/2024 - Cod. 150101...
DALI' CE DECLARATION OF CONFORMITY Company LARIUS srl Via Antonio Stoppani 21 - 23801 Calolziocorte (LC) ITALY Tel: +39 0341 621152 Fax: +39 0341 621243 E-mail: larius@larius.com Declares under his owns resonsibility that the product: DALI' Electric diaphragm pump complies with the directives: - EC Directive 2006/42 Machinery Directive - EU Directive 2014/30 Electromagnetic Compatibility (EMC) - EU Directive 2014/35 Low Voltage (LVD)
Need help?
Do you have a question about the Dali LAK18957/1 and is the answer not in the manual?