Getting Started

LED and Beeper Indicators

The scanner's beeper sounds and its green LED illuminates to indicate various functions
or errors on the scanner. The tables below list these indications. One exception to the
behaviors listed in the tables is that the scanner's functions are programmable, and may
or may not be turned on. For example, certain indications, such as the power-up beep
can be disabled using programming bar code labels.
Green LED Indications
LED
INDICATION
Power-on
Bright green flash
indication
Good Read
Bright green flash
Indication
Scanner Ready
Constant dim green
Constant green flash
Sleep Mode
(100mS on, 1900mS off)
Constant green flash at 1 Hz
Host Disable
(100mS on, 900mS off)
Varies (see
Diagnostics
page 1-5 for more information)
BEEPER FUNCTIONS
BEEPER
INDICATION
Power On Beep
Single beep
Good Read
Single beep
Indication
Varies (see
Diagnostics
page 1-5 for more information)
Programming
Varies (see the Product Reference
Mode
Guide for more information about
Indications
scanner programming)
1-4
INDICATION
Indicates the scanner has finished all its power up tests and is
now ready for ooperation.
Indicates a bar code has been read and decoded.
The scanner is ready for operation.
The scanner is in Sleep Mode. To wake the scanner up, move
an object in front of its window or press the button atop the
unit.
The scanner is disabled due to receiving a disble command
from the POS terminal.
"Error Codes"
on
The LED can provide diagnostic feedback if the scanner dis-
covers a problem during SelfTest.
INDICATION
"Error Codes"
on
COMMENT
COMMENT
The Power-On LED indication is a configurable feature which
can be enabled or disabled. When enabled, this beep Indi-
cates the scanner has finished all its power up tests and is
now ready for operation.
The good read beep indication is configurable. Options
include: Enable/disable, frequency, duration and volume. See
the Product Reference Guide (PRG) for more information.
The Beeper can provide diagnostic feedback if the scanner
discovers a problem during SelfTest.
The Beeper will sound as programming bar code labels are
scanned, indicating progress during scanner configuration.
®
Magellan