Download Print this page
SPX POWER TEAM PA9-LP Operating Instructions Manual

SPX POWER TEAM PA9-LP Operating Instructions Manual

Air hydraulic pump

Advertisement

Quick Links

SPX Corporation
5885 11th Street
Rockford, IL 61109-3699 USA
Internet Address:
http://www.powerteam.com
Workstation Sound Pressure Level: 80 dB(A) at Rated Capacity
Definition: An air hydraulic pump delivers hydraulic fluid under pressure through the use of compressed air
as a power source.
Two safety symbols are used to identify any action or lack of action that can cause personal injury. Your
reading and understanding of these safety symbols is very important.
DANGER - Danger is used only when your action or lack of action will cause serious human injury or
death.
WARNING - Warning is used to describe any action or lack of action where a serious injury can occur.
IMPORTANT - Important is used when action or lack of action can cause equipment failure, either immediate
or over a long period of time.
WARNING: It is the operator's responsibility to read and understand the following
safety statements,
Only qualified operators should install, operate, adjust, maintain, clean, repair, or
transport this machinery.
These components are designed for general use in normal environments. These
components are not specifically designed for lifting and moving people, agri-food
machinery, certain types of mobile machinery or special work environments such as:
explosive, flammable or corrosive. Only the user can decide the suitability of this
machinery in these conditions or extreme environments. Power Team will supply
information necessary to help make these decisions.
These instructions are intended for end-user application needs. Most problems with new equipment are caused by
improper operation or installation. Detailed service repair instructions or parts lists can be obtained from your nearest
Power Team facility (see listing).
© SPX Corporation
®
Tech. Services: (800) 477-8326
Fax: (800) 765-8326
Order Entry: (800) 541-1418
Fax: (800) 288-7031
AIR HYDRAULIC PUMP
Max. Pressure: See Pump Data Plate
SAFETY EXPLANATIONS
Form No. 1000039
Operating Instructions for:
Sheet No.
Rev
PA9-LP
1 of 4
Date: 24 Aug 2003

Advertisement

loading
Need help?

Need help?

Do you have a question about the PA9-LP and is the answer not in the manual?

Questions and answers

Summary of Contents for SPX POWER TEAM PA9-LP

  • Page 1 SPX Corporation Tech. Services: (800) 477-8326 5885 11th Street Fax: (800) 765-8326 Rockford, IL 61109-3699 USA Order Entry: (800) 541-1418 PA9-LP Fax: (800) 288-7031 Internet Address: http://www.powerteam.com AIR HYDRAULIC PUMP Max. Pressure: See Pump Data Plate Workstation Sound Pressure Level: 80 dB(A) at Rated Capacity Definition: An air hydraulic pump delivers hydraulic fluid under pressure through the use of compressed air as a power source.
  • Page 2: Safety Precautions

    Operating Instructions, Form No. 1000039, Back sheet 1 of 4 SAFETY PRECAUTIONS WARNING General Operation • All WARNING statements must be carefully observed to help prevent personal injury. • Before operating the pump, all hose connections must be tightened with the proper tools. Do not overtighten.
  • Page 3: Hydraulic Connections

    Operating Instructions Form No. 1000039 Hydraulic Connections Clean all the areas around the fluid ports of the pump and cylinder. Inspect all threads and fittings for signs of wear or damage and replace as needed. Clean all hose ends, couplers and union ends. Remove the thread protectors from the hydraulic fluid outlets.
  • Page 4: Pump Operation

    Operating Instructions, Form No. 1000039, Back sheet 2 of 4 OPERATION PICTOGRAM DEFINITIONS Activating the pump with the pedal end marked with this pictogram, the flow of fluid is directed out of the reservoir. Activating the pump with the pedal end marked with this pictogram, the flow of fluid is directed back to the reservoir.
  • Page 5: Preventive Maintenance

    Operating Instructions Form No. 1000039 OPERATION (CONTINUED) Adjusting The Release Mechanism 1. Loosen the “Adjusting Screw”. Foot 2. Verify that the “Adjusting Plate” is free. Adjusting Adjusting Air Inlet Pedal Screw Plate 3. Depress the “Air Inlet Stem” with the “Foot Stem Pedal”.
  • Page 6 Operating Instructions, Form No. 1000039, Back sheet 3 of 4 PREVENTIVE MAINTENANCE (CONTINUED) Draining And Flushing The Reservoir IMPORTANT: Wipe the pump exterior completely clean before attempting this procedure! 1. Drain the bladder of all oil and refill half full with clean hydraulic oil. Rinse the filter clean. 2.
  • Page 7 Operating Instructions Form No. 1000039 OPERATOR TROUBLESHOOTING GUIDE If this guide does not resolve your pump problem, contact an authorized hydraulic service center or a company headquarters listed on back sheet 4 of 4. PROBLEM CAUSE SOLUTION Pump reciprocates but no oil 1.
  • Page 8: Power Team Facilities

    Operating Instructions, Form No. 1000039, Back sheet 4 of 4 POWER TEAM FACILITIES ® UNITED STATES CHINA EUROPE C E R T I F I E D SPX Corporation-Fluid Power 212 Jiang Ning Road Albert Thijsstraat 12 CATIC Tower 23C 6471 WX Eygelshoven 5885 11th Street Shanghai 200041, China...