Page 1
ROOMFLEX 40 FITTING INSTRUCTIONS KIT AND DOOR SPECIFICATION Kit Short Code Door Configuration Max. Door Height Max. Door Width Max. Door Thickness HRP2/0 3000mm 838mm 35-44mm 40kg 2+0 KIT CONTENTS TOOLS REQUIRED WRAP AROU WRAP AROUND WRAP ARO HINGE WRAP ARO...
Note: Ensure opening is square, level and all load bearing areas are suitable for weight of system. Ensure there is sufficient strength in structure above the opening to take concentrated weight of doors when open. Roomflex 40 provides +/- 5mm of horizontal adjustment. Ensure doors are measured accurately prior to installation.
Page 3
SECURE TRACK POSITION TIMBER HEADERS AS SLIDE PIVOT INTO PLACE. PER THE BELOW. BLOCK FLUSH TO FRAME. DT - 6 SECURE IN PLACE. INSTALLATION 1. Ensure that you have all the required parts. Unpack the com- ponents and identify the parts. Lay the parts on the ground in the same con guration as they will be when installed.
Page 4
FLUSH PULL ROUTING DETAIL ROUTE FLUSH BOLTS (SEE DIAMGRAM 1 FOR LOCATION). SECURE FLUSH BOLTS USING 30MM SCREWS PROVIDED. DOOR HINGES & OVERVIEW DIAGRAM 4 20mm 20mm JAMB REBATE HANGER HINGE SET 110mm JAMB JAMB JAMB REBATE INTERMEDIATE HANGER SET JAMB PIVOT SET PIVOT SET...
Page 5
JAMB JAMB JAMB JAMB PIVOT SET PIVOT SET PIVOT SET RAISE DOOR 1 5MM FROM FLOOR. SLIDE STRAP BOLT THROUGH UNSCREW NUT, SLIDE STRAP BOLT BOTTOM HINGE AND INTO LINK THROUGH HINGE AND REATTACH ARM. TIGHTEN WITH 5MM ALLEN NUT. TIGHTEN WITH 5MM ALLEN KEY. KEY.
Use hinge handle to folding doors bolts bolts pull Door 1 and Door 2 into fully closed position P C HENDERSON LTD UK SALES IRELAND SALES INTERNATIONAL SALES 370977 Durham Road, Bowburn, t: +44 (0) 191 377 7345 t: +353 (0)1 643 6816...