Banner R95C Instruction Manual

8-port 2-channel discrete and analog in-out modbus hub
Hide thumbs Also See for R95C:

Advertisement

Quick Links

R95C 8-Port 2-Channel Discrete and
Analog In-Out Modbus® Hub Instruction
Manual
Original Instructions
p/n: 234539 Rev. A
June 26, 2024
© Banner Engineering Corp. All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R95C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Banner R95C

  • Page 1 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Original Instructions p/n: 234539 Rev. A June 26, 2024 © Banner Engineering Corp. All rights reserved.
  • Page 2: Table Of Contents

    Chapter 3 Mechanical Installation Wiring........................................... 16 Chapter 4 Status Indicators....................17 Chapter 5 Specifications FCC Part 15 Class B for Unintentional Radiators............................19 Industry Canada ICES-003(B)..................................20 Dimensions ........................................20 Chapter 6 R95C Accessories....................21 Chapter 7 Banner Engineering Corp Limited Warranty............. 24...
  • Page 3: Chapter 1 Features

    Overview The R95C 8-Port 2-Channel Discrete and Analog In/Out Modbus® Hub provides a mix of both discrete input/output and analog input/output functionality distributed to two sets of 4-ports Ports 1 through 4 contain the discrete functionality, and Ports 5 through 8 contain the analog functionality. These two sets of ports can be monitored and configured using an Modbus registers.
  • Page 4: Analog In/Out Configuration

    R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Discrete In/Out Configuration ....................................4 Analog In/Out Configuration ....................................4 Modbus Configuration ......................................4 Chapter 2 Configuration Instructions Discrete In/Out Configuration Ports 1 through 4 contain discrete functionality. The figure below details the logic flow for each of the four bimodal discrete in/ out ports, and the tables define the configuration for each pin of the four bimodal ports.
  • Page 5 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Continued from page 4 Modbus Register Description I/O Range Comments Default Access Notes Address Measurement Value Voltage = mV, 40003 0..65535 - Analog In Port 5 Current = µA...
  • Page 6 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Configuration Instructions Instruction Manual Continued from page 5 Modbus Register Description I/O Range Comments Default Access Address Port 3 Pin 4 Active 40509 0..1 0 = Inactive, 1 = Active State...
  • Page 7 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Alias Read/Only Addresses Modbus Register Description I/O Range Comments Register to Assign Access Address Alias Register 40701 0..65535 Value shows up in 40501 45001 Address Alias Register 40702 0..65535...
  • Page 8 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Configuration Instructions Instruction Manual Continued from page 7 Modbus Register Description I/O Range Comments Register to Assign Access Address Alias Register 40727 0..65535 Value shows up in 40527 44011 Address Alias Register 40728 0..65535...
  • Page 9 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Continued from page 8 Modbus Register Description I/O Range Comments Default Access Address Alias RW Register 40821 0..65535 User defined Value Alias RW Register 40822 0..65535 User defined...
  • Page 10 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Configuration Instructions Instruction Manual Continued from page 9 Modbus Register Description I/O Range Comments Register to Assign Access Address Alias Register 40913 0..65535 Value shows up in 40813 Address Alias Register 40914 0..65535...
  • Page 11: Multi-Port Support: Ports 1-4

    Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Continued from page 10 Modbus Register Description I/O Range Comments Default Access Address Restore Factory 0 = No Operation, 1 = 40605 Configuration Restore Device Information Modbus Register...
  • Page 12 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Configuration Instructions Instruction Manual Continued from page 11 Modbus Register Description I/O Range Comments Default Access Notes Address Lower 16 of 32 bits = Running Pin 4 Count 41004 Pin 4 Count L 0..65535...
  • Page 13 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Continued from page 12 Modbus Register Description I/O Range Comments Default Access Notes Address Pin 2 Count 41103 Pin 2 Count L 0..65535 Lower 16 of 32 bits...
  • Page 14 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Configuration Instructions Instruction Manual Pin 2 Port Configuration (White - Female, Discrete 2) Modbus Register Description I/O Range Comments Default Access Notes Address 0 = NPN input 1 = PNP input...
  • Page 15: Multi-Port Support: Ports 5-8

    Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Multi-Port Support: Ports 5-8 Register Ranges for Ports 5-8 Register Ranges Port Number 45001-45305 Port 5 46001-46305 Port 6 47001-47305 Port 7 48001-48305 Port 8 Measurement Reads...
  • Page 16: Wiring

    Chapter 3 Mechanical Installation Install the R95C to allow access for functional checks, maintenance, and service or replacement. Do not install the R95C in such a way to allow for intentional defeat. Fasteners must be of sufficient strength to guard against breakage. The use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the device.
  • Page 17: Chapter 4 Status Indicators

    Status Indicators On both sides of the R95C Modbus hub, Ports 1 through 4 have two matching amber LED discrete output indicators, and Ports 5 through 8 have two matching amber LED analog in/analog out indicators. There is also an additional amber LED indicator on both sides of the converter, which is specific to the Modbus communication, and a green LED indicator that shows power status.
  • Page 18 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Status Indicators Instruction Manual Continued from page 17 Indication Status Flashing Amber (4 Modbus communications are active Solid Amber for 2 Seconds, Then to Modbus communications are lost after connection Solid Amber for 2...
  • Page 19: Chapter 5 Specifications

    R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents FCC Part 15 Class B for Unintentional Radiators .............................. 19 Industry Canada ICES-003(B).................................... 20 Dimensions......................................... 20 Chapter 5 Specifications Supply Voltage Operating Conditions 12 V DC to 30 V DC at 400 mA maximum (exclusive of load) Temperature: –40 °C to +70 °C (–40 °F to +158 °F)
  • Page 20: Industry Canada Ices-003(B)

    R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Specifications Instruction Manual • Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • Page 21: Chapter 6 R95C Accessories

    R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Chapter 6 R95C Accessories Cordsets 4-pin M12 Cordsets - Female Straight to Male Right-Angle Double-Ended Model Length Dimensions (mm) Pinouts BC-M12F4-M12M4A-22-1 1 m (3.28 ft) Female 32 Typ.
  • Page 22 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub R95C Accessories Instruction Manual Continued from page 21 4-Pin Threaded M12 Male to 5-Pin Threaded M12 Female Splitter Cordset Model Branches (Female) Wiring M12 x 1 M12 x 1 5-Pin Threaded M12 Splitter Cordset with Flat Junction—Double Ended...
  • Page 23 R95C Accessories R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual 5-Pin Molded Junction Blocks Model Pinout (Male) Pinout (Female) R50-4M125-M125Q-P Molded Junction Block • Four integral 5-pin M12 female quick- disconnect connectors • One integral 5-pin M12 male quick- disconnect connector •...
  • Page 24: Chapter 7 Banner Engineering Corp Limited Warranty

    Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
  • Page 25 LinkedIn Twitter Facebook © 2024. All rights reserved. www.bannerengineering.com...

This manual is also suitable for:

R95c-4b4ui-mq

Table of Contents