5.4 Universal (Input) Safety Modules ..............................20 6 Product Support and Maintenance ..........................21 6.1 Maintenance and Service ................................21 6.2 Status Indicators ....................................21 6.3 Information Available via ISD ................................ 22 6.4 Contact Us .....................................23 6.5 Banner Engineering Corp. Limited Warranty ..........................24...
The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. Please contact a Banner Applications Engineer with any questions regarding this product.
1.3 EU Declaration of Conformity (DoC) Banner Engineering Corp. herewith declares that these products are in conformity with the provisions of the listed directives and all essential health and safety requirements have been met. For the complete DoC, please go to www.bannerengineering.com.
SI-RF Non-Contact RF Safety Switch 2 Configuration Instructions 2.1 Safety Code for Operation The actuator of the SI-RF Safety Switch system has a non-modifiable safety code for distinct and error-free identification. This code must be submitted to the SI-RF Safety Switch and permanently saved in the SI-RF Safety Switch. Three different coding levels are available: •...
SI-RF Non-Contact RF Safety Switch 3 Installation Instructions 3.1 Installation Requirements The following general requirements and considerations apply to the installation of interlocked gates and guards for the purpose of safeguarding. In addition, the user must refer to the relevant regulations and comply with all necessary requirements.
SI-RF Non-Contact RF Safety Switch WARNING: • The hazard must be accessible only through the sensing field • Incorrect system installation could result in serious injury or death. • The installation of the SI-RF Safety Switch must prevent any individual from reaching around, under, over or through the defined area and into the hazard without being detected.
SI-RF Non-Contact RF Safety Switch 3.4 Sensing Distance Figure 1. Actuation directions The switching distances of the standard actuation direction 1 are listed. The distances noted are for a sensor working with the standard actuators (SI-RF-A and SI-RF-A2). Sensing Distance (Only in conjunction with actuator SI-RF-A) Minimum Typical Maximum...
Failure to follow these instructions could result in serious injury or death. • Application of power to the Banner device, the closing of the movable safety guard, or the reset of a manual restart condition MUST NOT initiate dangerous machine motion. Design the machine control circuitry so that one or more initiation devices must be engaged (in a conscious act) to start the machine - in addition to the Banner device going into Run mode.
SI-RF Safety Switch. A Banner XS26-2 Safety Controller with XS1ro or XS2ro Relay Expansion Module, Banner SC10-2roe Safety Controller, or Banner UM-FA-xA Universal Safety Module provides a series connection of redundant contacts that form protective stop circuits for use in either single-channel or dual-channel control.
Failure to follow these instructions could result in serious injury or death. WARNING: OSSD Interfacing To ensure proper operation, the Banner device output parameters and machine input parameters must be considered when interfacing the Banner device OSSD outputs to machine inputs. Machine control circuitry must be designed so that the maximum load resistance value is not exceeded and that the maximum specified OSSD Off-state voltage does not result in an On condition.
SI-RF Non-Contact RF Safety Switch +24Vdc 0Vdc XS/SC26-2xx XS2so or XS4so SI-RFPT..M +24Vdc 1 - Brown +24 V dc 0Vdc 5 - Grey PNP OUT * LOAD 2 - White OSSD1 SO1a FSD1 4 - Black OSSD2 (SO1 not split) 3 - Blue 0V dc SO1b...
SI-RF Non-Contact RF Safety Switch 3.8.5 Wire the Switch in Series To monitor several movable safety guards with a series connection of SI-RF Safety Switch, follow these steps. 1. Connect the safety outputs of the last SI-RF Safety Switch to a safety monitoring unit. 2.
Page 14
SI-RF Non-Contact RF Safety Switch PNP Aux Output NOT FOR SAFETY MQDC-4xx SI-RFA-TK Power Safety Reset Monitoring Module ONLY FOR DOOR 4 DEE2R-8xxD 24Vdc 0Vdc SI-RFA-TK MQDC-4xx SI-RFA-P MQDEC-4xxSS MQDEC-4xxSS MQDEC-4xxSS OSSDs MQDC-4xx SI-RFA-TS SI-RFA-TS SI-RFA-TS SI-RFA-TS Component Key 4-pin male connection SI-RFA-TK 8-pin female connection SI-RFA-TS...
Page 15
SI-RF Non-Contact RF Safety Switch Max. Total Series Cable (m) Single Power Supply SI-RF E-Stops Number of ISD Devices Figure 10. Maximum total cable length for a single power supply WARNING: • Safety devices with OSSDs and without ISD, such as safety light curtains, are not compatible. •...
SI-RF Non-Contact RF Safety Switch 4 Specifications Important: The SI-RF Safety Switch should be connected only to a SELV (Safety Extra-Low Voltage), for circuits without earth ground or a PELV (Protected Extra-Low Voltage), for circuits with earth ground power supply, according to EN/IEC 60950. Rated supply voltage (U Rated conditional short-circuit current Switching frequency...
SI-RF Non-Contact RF Safety Switch Model Description SI-RFA-TK SI-RF T-adapter for connection of the reset button, 8 pin to 4 pin to 8 pin SI-RFA-P SI-RF Termination plug M12 SI-RFA-DM1 SI-RF Diagnostic Module with 8 digital outputs and 1 diagnostic circuit Interfaces: IO-Link, USB 2.0 SI-RDA-DM2 SI-RF Diagnostic Module with 1 diagnostic circuit...
SI-RF Non-Contact RF Safety Switch 6 Product Support and Maintenance 6.1 Maintenance and Service Remove all contamination by metal-based materials to avoid reducing the switch distance. Do not use alcoholic cleaning agents. The SI-RF Safety Switch is maintenance-free. For long-term and trouble-free operation, please periodically check the following points: •...
SI-RF Non-Contact RF Safety Switch Information Available via ISD The following information can been obtained from the ISD chain and a diagnostic unit or ISD enable Safety Controller. Table 1: Cyclic Data about the Chain Short Name Data Format Meaning of data Count Mismatch The number of devices in the chain does not match the configuration Order Mismatch...
SI-RF sensor. Expected Company Name Banner's company code is 6 Received Company Name Banner's company code is 6 6.4 Contact Us Banner Engineering Corp. headquarters is located at: www.bannerengineering.com - Tel: + 1 888 373 6767...
6.5 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.