TSI Instruments Flowmaster 250 MK2 Operation And Maintenance Manual

TSI Instruments Flowmaster 250 MK2 Operation And Maintenance Manual

Portable flow & pressure test instrument, invaluable for hydrant testing, pump testing, flushing and water main condition testing

Advertisement

Quick Links

Operation and
Maintenance Manual
Flowmaster 250 MK2
Portable Flow & Pressure Test Instrument.
Invaluable for hydrant testing, pump testing, flushing
and water main condition testing.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Flowmaster 250 MK2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TSI Instruments Flowmaster 250 MK2

  • Page 1 Operation and Maintenance Manual Flowmaster 250 MK2 Portable Flow & Pressure Test Instrument. Invaluable for hydrant testing, pump testing, flushing and water main condition testing.
  • Page 2: Specification

    GETTING TO KNOW YOUR FLOWMASTER What’s in the box? SPECIFICATION General Flowmeter Display Battery Pack Software Further Manuals FLOWMASTER OPERATION Flowmeter Display Power On Sequence Explanation of Display Panel USING YOUR FLOWMASTER Simple Steps to Fast Flow Analysis Precautions for Use MAINTENANCE &...
  • Page 3 1.1 What’s in the box? Flowmaster 250DL MK2 Battery Charger...
  • Page 5 250 MK2 Quick start guide...
  • Page 6 3.1 DISPLAY PANEL POWER-ON SEQUENCE Turn on the Flowmaster by pressing the ON/OFF switch to “I” position. When the Flowmaster is first turned on, the flow meter’s self-test mode will commence. This can last up to 5 seconds, after which the Flowmaster will be booted and ready for use.
  • Page 7: Precautions For Use

    4.1 SIMPLE STEPS TO FAST FLOW ANALYSIS IMPORTANT IMPORTANT - PLEASE READ THIS SECTION - PLEASE READ THIS SECTION BEFORE USING YOUR FLOWMASTER. BEFORE USING YOUR FLOWMASTER. It is important to think safety first, especially when working with pressure. It is important to think safety first, especially when working with pressure. It is important to think safety first, especially when working with pressure.
  • Page 8: Battery Maintenance

    5.2 FLOWMASTER MAINTENANCE 5.1 BATTERY MAINTENANCE - The battery pack operating time is 10 hours - Avoid dropping the Flowmaster. Use your hands to operate continuous usage. It is better to top up charge the the switches and avoid use of screwdrivers. Keep abrasive batteries at regular intervals than to allow full discharge.
  • Page 9 6.1 How to use the charger * It is recommended to power off the Flowmaster while charging the Li Ion battery. * - The charger is started by connecting the battery packer to the charger and then connecting the charger to the mains. - When the mains is connected the LED will be orange for approximately 8 seconds before turning to yellow when initialisation and analysis starts.
  • Page 10: External Battery/Chargers

    7.1 BALL VALVE FITTINGS The ball valve facilitates speedy and safe static pressure readings and creates back pressure for taking flow and residual pressure measurements BS Inst. Storz 7.2 TRANSPORT & STORAGE CASE Transport case with castor wheels and extension handle. Foam interior cut to hold Flowmaster and accessories.
  • Page 14 Operation & Manual Maintenance Manual Flowmaster 250 MK2 Portable Flow, Volume and Pressure measuring instrument...

This manual is also suitable for:

Flowmaster 250dl mk2