Installation and operating instructions
4 263 933-Ed.02 / 2024-07-Wilo

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wilo-COF-2B and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilo Wilo-COF-2B

  • Page 1 Pioneering for You Wilo-COF-2B Installation and operating instructions 4 263 933-Ed.02 / 2024-07-Wilo...
  • Page 2 Wilo-COF-2B https://qr.wilo.com/700...
  • Page 3 Fig. 1:...
  • Page 4 Fig. 2 Fig. 3...
  • Page 5 Fig. 4a Fig. 4b...
  • Page 7: Table Of Contents

    General preparations and control measures ....................12 Commissioning the system ..........................13 Decommissioning the system ..........................13 Maintenance ............................13 Faults, causes and remedies ......................13 Spare parts ............................14 Disposal ..............................15 Notice de montage et de mise en service Wilo-COF-2B...
  • Page 8: General

    NOTICE: bility to guard them against being touched. Useful notice on handling the product. It also • Guards which protect personnel from coming into highlights any potential difficulties. contact with moving components (e.g. couplings) WILO SE 07/2024...
  • Page 9: Safety Instructions For Installation And Maintenance Work

    • Eliminate any risk from electrical current. tem may be taken from the municipal water • Demarcate and cordon off the working area. supply or from a replenishment reservoir. • Define a personnel work plan for safe workflow. Installation and operating instructions Wilo-COF-2B...
  • Page 10: Technical Information

    NOTICE: installed. Each pump is equipped with: Suction-side gate valve Discharge-side non-return valve and gate valve Each collector tank is also fitted with a plug. WILO SE 07/2024...
  • Page 11: Operation

    COF-2B40-190 3“ accordance with regulations (i.e. in accordance COF-2B40-220 3“ with local regulations and conditions); the con- COF-2B32-105 2“½ nections for this purpose are marked accordingly COF-2B32-115 2“½ (see also the wiring diagram). COF-2B32-150 2“½ Installation and operating instructions Wilo-COF-2B...
  • Page 12: Commissioning

    • Pipework must run horizontally. be conducted by your closest Wilo customer ser- • The flow switch must be oriented in the direction vice agent or simply contact our central customer of fluid flow (see arrow on sensor housing).
  • Page 13: Commissioning The System

    10 Faults, causes and remedies Troubleshooting, particularly of problems relating to the pumps and switchgear, must be performed 9 Maintenance exclusively by a Wilo customer service agent or a Maintenance and repair work must only be carried specialist firm. out by qualified personnel!
  • Page 14: Spare Parts

    Wilo Spare parts may be ordered or repair work customer service agent. arranged via a specialist retailer and/or Wilo cus- tomer service. To avoid queries and incorrect orders, all data on the rating plate should be submitted with each order.
  • Page 15: Disposal

    For further information on recycling, go to www.wilo-recycling.com. For more information, visit www.wilo.com. Subject to change without prior notice. Installation and operating instructions Wilo-COF-2B...
  • Page 20 Local contact at www.wilo.com/contact WILO SE Wilopark 1 D-44263 Dortmund Germany T +49(0)231 4102-0 F +49(0)231 4102-7363 wilo@wilo.com Pioneering for You www.wilo.com...