Page 1
Instructions for installation and use Indirect, fully insulated dis- trict heating subtations Akva Lux II VXi, VXi Solo Indirect district heating substation for heating and domestic hot water. Fully insulated for very low heat losses. www.danfoss.com...
The substation must be handled and moved with the greatest care See item 19, page 41 for more detailed Guidelines for Water Quality in Danfoss and attention. brazed heat exchangers and recommended Chloride concentration to avoid Stress Corrosion Cracking.
Akva Lux II VXi, VXi Solo HWP, VXi Solo H 9. RECIRCULATION (ONLY AKVA LUX II VXI) Circulation set for Akva Lux II VXi substations is available as extra equip- ment. The set applies to various substation types, therefore excess components may occur.
2 / 8 VA Do not forget to establish potential equalization. For further information please see enclosed instruction manual. The Akva Lux II VXi and VXi Solo are delivered with Danfoss ECL Pumpe UPM3 AUTO Comfort 210 or 310 controllers from factory.
AVPB-F Di erential pressure controller (Akva Lux II VXi and VXi Solo H) For Akva Lux II VXi and VXi Solo H, the di erential pressure controller is installed in the AVQM self-acting ow controller with integrated control valve. Please see page 18.
• Language = English, ‘Common controller settings” • Operating mode of the controller = Comfort “Sun” Symbol, • Application type = A337 (Akva Lux II VXi, VXi Solo HWP) • Application type = A230 (VXi Solo H), Circuit selector Heating circuit Motor speed and motor protection is set and the controller is func- tional is functionally tested, so it’s ready for use.
Akva Lux II VXi & VXi Solo H Manual override For controlling the heating circuit the Akva Lux II VXi and VXi Solo H are supplied with a self-acting ow controller with integrated con- trol valve Danfoss AVQM and a Danfoss AMV actuator placed in the primary return ow line.
Page 19
For controlling the heating circuit the VX Solo II HWP is supplied with Manual override a Danfoss AMV 150 or AMV 13 actuator and a Danfoss valve VS 2, placed on the primary return ow line. THE AMV actuator is electri- cally wired to the controller from factory.
Page 31
Use is not recommended * Hardness ration limits defined per experience and internal tests in Danfoss laboratory ** In case of three or more parameters evaluated with o consultancy is needed with Consultant for Corrosion & Microbiology or BU HHE Representative...