S P E C I F I C A T I O N S
10.2.21.
The measurement accuracy is based on the chosen test conditions, and is given
by:
where:
where:
where:
AT5600 User Manual 98-119 issue 30

RESP Test

����
= ����
+ 1.74(����
+ ����
����
����
����
A
is the total accuracy (dB)
T
is the basic relative accuracy (dB)
A
R
is the calibration accuracy.
A
C
is the correction for the input voltage level.
A
VI
is the correction for the output voltage level.
A
VO
����
= 1.0 ��������
����
= 0.1 + ( 0.000001 ∗ ����
����
����
0.01 ��������
����
=
����
��������
���� ����
0.01 ��������
����
=
����
��������
��������
is the test frequency (Hz)
F
M
is the measured input voltage (V)
V
MI
is the measured output voltage (V)
V
MO
+ ����
)
��������
��������
) ��������
����
Page 263