Step 1
Step 2
Step 3
Step 4
Step 5
78-15136-02
If you need to replace a failed stack member, you can hot swap or replace the
switch by following this procedure:
Get a replacement switch that has the same model number as the failed switch.
Power down the failed switch.
Make sure the replacement switch is powered off, and then connect the
replacement switch to the stack.
If you had manually set the member numbers for any members in the
Note
stack, you need to manually assign the replacement switch the same
member number as the failed switch. To assign the member number
manually, refer to the switch software configuration guide.
Make the same Ethernet and Gigabit Ethernet connections on the replacement
switch (as were on the failed switch).
Power on the replacement switch.
The replacement switch will have the same configuration for all the interfaces as
the failed switch and will function the same as the failed switch.