4
GENERAL INFORMATION
REGARDING THE SYSTEM
Below is some general information regarding the system, appli-
ance installation and products manufactured by Gruppo Piazzet-
ta S.r.l.
i
Please refer to the installation standards or other in-
formative documentation provided by the manufac-
turer for further information.
4.1

INSTALLATION ROOM

The appliance is to be installed in a room which allows installa-
tion, user and maintenance operations to be performed safely
and easily.
If the product being installed requires a power socket, the room
must also be provided with an earthed power supply in accord-
ance with current regulations.
a
Appropriate ventilation in the installation room must
be ensured (refer to the section " FRESH AIR INTAKE ").
The installation room and the area which is to be heat-
■ ■
ed must be suitable sized and have appropriate charac-
teristics in relation to the heating capacity of the appli-
ance. Compare the information provided in the section
" TECHNICAL DATA " with the power required by the
area which is to be heated.
If the room or the product installation area (technical
■ ■
room, perimeter walls, recess, supporting walls, etc.)
are not suitably insulated, the heating capacity of the
appliance will be reduced.
Consult a heating technician or engineer for a correct
■ ■
check and calculation of the requirement of the envi-
ronments to be heated and the corresponding regula-
tions.
The appliance cannot be installed or operated out-
■ ■
doors, only indoors or in suitable technical rooms. In-
stalling the appliance outdoors could create dangerous
situations, cause health problems or lead to operating
faults.
a
Make sure that the floor of the installation room is able
to withstand the weight of the product including any
cladding, accessories and trim. If the floor does not
have a suitable load-bearing capacity, take adequate
counter-measures.
PRODUCT INFORMATION, INSTALLATION AND MAINTENANCE
a
The existence of more than one appliance is only per-
mitted if allowed by the regulations and manufacturer
of each individual appliance.
If the existence of more than one appliance is permit-
■ ■
ted, all regulations and provisions supplied by the
manufacturer of each individual appliance are to be
respected.
C type gas appliances (please refer to legislation in
■ ■
force) are permitted in the installation room of the ap-
pliance.
d
The installation room must not be used to store flam-
mable material.
Further limitations for NON airtight installations and installa-
tions which do not have combustion air intake from outside
(according to UNI standards)
d
Installation room:
must not be a stairwell (unless the building has a maxi-
■ ■
mum of two rooms), a hallway or a room with a volume
of less than 15m
must not be a bedroom, a bathroom, a shower room or
■ ■
a studio flat with the exception of airtight installation
or the installation of an appliance with a closed firebox
with combustion air drawn and ducted directly from
outside
must not have a low pressure compared to the exte-
■ ■
rior due to a counter draught caused by the presence
of another appliance or extractor device in the room
where the appliance is installed (eg. forced ventilation
systems or other heating systems using ventilation to
change the air).
d
In the appliance installation room:
it is not permitted to install liquid fuel appliances with
■ ■
continuous or discontinuous functioning which draw
combustion air from the room where the appliance is
installed
simultaneous use of more than one appliance (two
■ ■
stoves or a fireplace and a stove, etc.) is not permitted
unless:
all provisions indicated by the manufacture of each
■ −
individual appliance have been respected
for heavy simultaneous use, the vacuum measured
■ −
between the internal and external environment is
lower than the value determined by law (4 Pa).
Type B gas appliances used for heating the room, with
■ ■
or without the production of domestic hot water are
not allowed
devices suitable for cooking food with relative hoods
■ ■
without an extractor fan may only be used in kitchens.