Page 1
New: overview of covers and line grommets (see Chapter 2.9/Page For qualified technicians only WAREMA slat roof Lamaxa L50 Installation Instructions Document number 2054143 [Rev. 7 - en]...
Table of contents Table of contents Safety and product information..................3 Installation......................... 7 Tools................................7 Unpacking the product..........................8 Scope of delivery............................8 Product position............................9 Erecting the poles............................10 Erecting the poles, star-mounted and series-mounted units..............11 Installing the wall console (optionally)......................12 Installing the fixing profile of the wall connection system on the wall via the beam (optionally)....13 Overview of the use of covers and line grommets on the pole..............
Performing tasks on the product that are not described in these instructions is not permissible. No other alterations are to be carried out on the product other than as described in these instructions without the written approval of WAREMA. If any questions arise before or during installation, please send an e-mail to or call +49 9391 20-1900.
Page 4
Safety and product information Parts description Slats Beams with slat seat Pole Push rod (push rod not visible) Base plate (e.g., external) Partition compensation plate Rain hood Connection box (optionally) Fig. 1: Parts description Page 4 | 46 2054143 [Rev. 7 - en]/2022-05-13...
Page 5
Safety and product information Weights 800 kg 750 kg 700 kg 4500 mm 650 kg 4000 mm 600 kg 3500 mm 550 kg 3000 mm 500 kg 2500 mm 450 kg 400 kg 350 kg 300 kg 250 kg 200 kg 2500 3000 3500 4000 4500 5000 5500 6000...
Page 6
Safety and product information Technical data LED strip (optionally) Parameter Value Output voltage 24 V Degree of protection IP 67 max. power 400 lm/m, 4.8 W/m Colour temperature 3000 Kelvin Tab. 1: Technical data of LED strip (round) Parameter WMS Dimmer smart Operating voltage [V AC] 200-240 Frequency [Hz] 50-60...
Installation Technical data Design radiant heater (optionally) INFO For the radiant heater, an in-line circuit breaker with type C16 ismandatory. Parameter Value Mains voltage 230–240 V AC/50 Hz Power consumption [W] 2200 Degree of protection IP 65 Safety class Dimensions LxWxH [mm] 900x170x80 Tab.
Check all parts to make sure they are not damaged. Compare the situation on-site with the order data. If any items are damaged or do not match the order data, discontinue installation and contact WAREMA. Ground connections with field of application Installation of glass permissible.
Installation Product position Electric distribution on the beam Pole Beam with slat seat Order width Order length Diagonal 1 poles (inside corner to inside corner) – dimension specified on order confirmation as aid Diagonal 2 poles (inside corner to inside corner) – dimension specified on order confirmation as aid Fig.
Installation Attach the base plate [1] to the threaded rod [6] without an intermediate layer. Fig. 8: Ground installation with threaded rod [6] Erecting the poles Order width Order length Diagonal 1 poles (inside corner to inside corner) – dimension specified on order confirmation as aid Diagonal 2 poles (inside corner to inside corner) –...
Installation Erecting the poles, star-mounted and series-mounted units Fig. 10: Erecting and aligning the poles, star-mounted and series-mounted units [1] Attach the covers of all base plates, if present. [1] Attach 1 base plate to each pole with 4 screws DIN 7500 M8x30 each. [2] Pass the on-site supply line through the opening in the base plate of the pole for the supply line.
Installation Installing the wall console (optionally) Order width Headroom (order data) Fig. 11: Installing the wall console (dimensions in mm) INFO Pencil in the fixing positions centrally to allow corrections later on. Watch the edge distances. INFO Check the mounting substructure for unevenness. Correct any unevenness.
Installation Installing the fixing profile of the wall connection system on the wall via the beam (optionally) Fig. 12: Installing the wall connection profile (dimensions in mm) [1a] Transfer the height to the mounting substructure. [1a] Hold the fixing profile against the marking and align it vertically and horizontally. [1a] Centre the fixing profile lengthwise on the beam.
Installation Overview of the use of covers and line grommets on the pole Cover and its use Line grommets and their use Cover for inside of pole at installation point Mab/Mda (side without connection box) Cover for inside of pole with cable con- duit at installation point Mbc/Mcd (side with connection box) (sealing area...
Page 15
Installation Cover and its use Line grommets and their use Cover for series-mounted unit, inside of right pole (side without connection box) Cover for series-mounted unit, inside of left pole (side without connection box) Cover for series-mounted unit, inside of right pole with cable conduit (side with connection box) (sealing area...
Installation Cover and its use Line grommets and their use Cover for star-mounted unit, inside of pole (side without connection box) Cover for star-mounted unit, inside of pole with cable conduit (side with con- nection box) (sealing area 5– (sealing area 6– 21 mm) 10 mm) On-site con-...
Installation [1a] Place 1 beam from above onto the 2 erected poles and fasten the beam using 2 wedge-locked washers 8.7x16.6 and 2 screws DIN 7984 M8x16. [1b] Erect 1 more pole and install the 2nd beam in an L-shape. [1a + 1b] Erect the 4th pole and, if necessary, the 5th pole (optionally) and also install the 2 remaining beams. [1c] Push in the covers (inside, for assignment see Chapter 2.9/Page 14) at all 4 poles from the top downward and...
Page 18
Installation [1a] Place 1 beam from above onto the 2 erected poles and fasten the beam using 2 wedge-locked washers 8.7x16.6 and 2 screws DIN 7984 M8x16. [1b] Erect 1 more pole and install the 2nd beam in an L-shape. [1c] Push in the covers (inside, for assignment see Chapter 2.9/Page 14) at 2 poles from the top downward and screw from the top downward using the screws ISO 4762 M6x190.
Installation 2.12 Installing the beams, star-mounted and series-mounted units Fig. 15: Installing the beams, star-mounted and series-mounted units INFO Note the different beam versions and their positions. The exact positions of the various beams can be seen in the accompanying sketch. [1a + 1b] Place the beams from above onto the corner poles and fasten each one using 2 wedge-locked washers 8.7x16.6 and 2 screws DIN 7984 M8x16.
Installation [2] Place the beams from above onto the series poles and fasten each one using 2 wedge-locked washers 8.7x16.6 and 2 screws DIN 7984 M8x16. [3] Place the beams from above onto the star poles and fasten each one using 2 wedge-locked washers 8.7x16.6 and 2 screws DIN 7984 M8x16.
Installation Measure the diagonals D1 and D2 between the inside corners of the beams. The dimension is specified on the order confirmation as an aid. If D1 = D2 , the beams are parallel. Measure diagonals D1 and D2 between the poles (all fields F –F ).
Page 22
Installation INFO Install the corner joint using the hole on the pole with drainage. NOTICE Insufficient tightness at the corners! The tightness depends on the care with which the sealing adhesive is distributed and smoothed after the corner joint is inserted.
Page 24
Installation NOTICE Insufficient tightness at the corners! The tightness depends on the care with which the sealing adhesive is distributed and smoothed after the corner joint is inserted. Water droplets form in the area of the corners if the work is not performed carefully. Distribute sealing adhesive liberally on all labelled areas.
Installation INFO [2c] Note the installation direction relative to the connection box: The line ends of the light rail must face the connection box. [1] Remove the protective strip from the adhesive tape on the light rail. [2a] Attach the hooks of the light rail to the corresponding beam. [2b] Press the light rail firmly against the rain gutter of the beam using screw clamps.
Installation Insert the wires all the way into the connector. Note the colours. Using an aid such as tongue-and-groove pliers, push in the two activation levers of the connector so they are flush. 2.18 Installing the Basic power distributor (optionally) Fig.
Installation [1d] Install the cover on the inside of the pole. [1e] Install the plug connector on the supply line: Strip approx. 7 mm off the ends of the single conductors. ■ Pass the earth cable through the metric screw connection. ■...
Installation 2.20 Installing the Design radiant heater (optionally) Parts description Design radiant heater Cover cap e. g. left Console g. g. left Housing for the Design radiant heater Screw DIN 912 M5x30 Screw 6x20 Washer DIN 125 5.3 Screw DIN 7982 3.5x13 Fig. 24: Parts overview of the Design radiant heater Technical data INFO Maximum number per slat roof is 2 pieces...
Page 30
Installation INFO The radiant heater must be mounted at a height [A] of at least 2100 mm above the floor or another surface with steady traffic. The minimum distances of 1000 mm to the front toward flammable materials [C] must be maintained. The minimum inclination angle [E] is 30°, the maximum adjustment range [D] is 10°...
Page 31
Installation [1c] Attach the intermediate plate to the rain gutter using the drilling screws Zebra Pias 3.9 x25 (in accessories). [2] Attach the console in the housing for the Design radiant heater using the 2 screws M6x20. Ensure you are using the correct side.
Page 32
Installation Installing the radiant heater on the housing Fig. 29: Installing the radiant heater on the housing [1a] Unscrew the screws from the radiant heater. INFO The screws are needed to attach the radiant heater to the console later on. [1b] Position the radiant heater in front of the housing and pass the radiant heater line through the opening in the housing to the outside.
Page 33
Installation Connecting the radiant heater Connect the STAS 3 coupling to the extension. Fig. 31: Coupling STAS 3 Route the extension in a wide arc around the installed plug-in connector. Connect the plug-in connector. Attach the extension to the panel above and below using the preinstalled cable ties.
Installation Slide the cover cap [1] sideways onto the housing until the two snaplock parts [2 and 3] are engaged. Secure the cover cap [1] using the screw [4]. Cover cap Snaplock on the console (permanently installed) Snaplock Screw in the DIN 7982 cover cap 3.5x13...
Page 35
Installation Fig. 36: Installing the slats [1] Press all bushings into the provided openings in the beam. [2] Install and fasten the slat with the motor. [2a] Insert the slat in the mount. ■ [2a] Attach the motor holder of the slat with the motor to the beam using 2 screws Zebra Pias A2 4.8x25. ■...
Attach the already installed slats to the push rod. 2.22 Setting the motor limit positions INFO Teach the motor limit position of the slat roof using the WAREMA Smart programming cable. INFO Note the "Setting instructions and wiring diagram" included with the drive. 2.23...
Installation 2.24 Line routing within the product WARNING Risk of electric shock from insufficient care! The line can be damaged by moving parts! Keep the line away from all moving parts. INFO Inspect the lines. If the line is damaged, the product is not permitted to be connected. The 230 V line must be routed separately from the 24 V line.
Page 38
Installation Line label Meaning Note LED Ta LED strip in light rail at beam Ta LED installed and line routed in light rail to connection box LED Tb LED strip in light rail at beam Tb LED installed and line routed in light rail to connection box LED Tc LED strip in light rail at beam Tc...
Page 39
Installation INFO For RGB strips, two connectors are used. Strip Extension line Dimmer Black Black Black Green Orange Orange Blue Brown Brown Tab. 12: RGB colour assignment Special feature of RGB strip: direct connection with dimmer Insert the wires all the way into the connector. Note the colours. Using an aid such as tongue-and-groove pliers, push in the two activation levers of the connector so they are flush.
Installation Strip the lines. Equip the lines with ferrules. Insert the line (see label) into the corresponding slot on the printed circuit board. 2.26 Performing a functional check (slat roof) CAUTION Risk of crushing from failure to exercise care during operation. Persons who are located within the projection area may be injured.
Installation Cutting of the supply line at the distributor GEFAHR DURCH STROM Electric shock! The supply line on the distributor is connected to the power supply via the personal protection line. Before cutting off the supply line at the distributor, the PRCD-S personal protection line must be unplugged again. INFO With RGB strips: only cut off the supply line after the RGB hand-held transmitter has been taught and the power socket has been tested.
Installation 2.28 Installing the protection profile (optionally) Fig. 38: Installing the protection profile [1a] Take the hinge out of the packaging and release the black pin with a size 5 hex key. NOTICE The hinge arms are under tension when delivered. Remove the pin from the hinge by moving the tool back and forth.
Installation 2.29 Finishing the installation Programming the RGB strip for the hand-held transmitter INFO Teach the hand-held transmitter for the product (see the accompanying installation and operating instructions for the hand-held transmitter). The hand-held transmitter must be no farther than 50 mm away from the dimmer. To teach the RGB strips, hold the hand-held transmitter a maximum distance of 50 mm away from the dimmer.
Page 44
Installation Installing the covers Fig. 39: Finishing the installation [1a] Attach the rain hoods for beams B and C to the hinge and lower. [1b] Attach the rain hoods to the predrilled holes, each with 1 screw DIN 7981 A2 C 3.5x25. [2a] Screw the cover (outside) on all poles from the top downward using the screws ISO 4762 M6x190.
Page 45
Installation [2c] If an offset pole is present, push in the cover (outside) from the bottom to the top and fasten it to the retaining plate using 2 sheet tapping screws DIN 7981 3.5x13. [2b] For a star-mounted or series-mounted unit, push in the cover (outside) at the series pole from the bottom to the top and fasten it to the retaining plate using 2 sheet tapping screws DIN 7981 3.5x13.