Table of Contents 1. Package Contents ..................3 2. Requirements ....................4 3. Wiring the Power Inputs ................. 5 3.1 Grounding the Device ................7 4. Terminal Setup ....................8 4.1 Logging on the Console ................9 4.2 Configuring IP Address via Console ............11 4.3 Storing the Current Switch Configuration ..........
1. Package Contents Thank you for purchasing PLANET L3 Industrial Managed Switch, IGS-5225-8T2S2X or IGS-5225-8P2S2X. The descriptions of these models are as follows: Industrial L3 8-Port 10/100/1000T + 2-Port 1G/2.5G SFP + IGS-5225-8T2S2X 2-Port 10G SFP+ Managed Ethernet Switch (-40~75 degrees C) Industrial L3 8-Port 10/100/1000T 802.3at PoE + 2-Port IGS-5225-8P2S2X 100/1G/2.5G SFP + 2-Port 10G SFP+ Managed Ethernet Switch (-40~75 degrees C) “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the above two models. Open the box of the Industrial Managed Switch and carefully unpack it. The box...
2. Requirements The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management: z Workstations running Windows 7/8/10/11, macOS 10.12 or later, Linux Kernel 2.6.18 or later, or other modern operating systems are compatible with TCP/IP Protocols. z Serial Port Connection (Terminal) The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
Page 6
2. Tighten the wire-clamp screws for preventing the wires from loosening. Power 1 Power 2 Model Positive (+) Pin Negative (-) Pin IGS-5225-8T2S2X Pin 1/5 Pin 2/6 IGS-5225-8P2S2X The wire gauge for the terminal block should be in the range from 12 to 24 AWG. Please check the wired AWG ampere specification before connecting PLANET industrial switch.
3.1 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device. Earth Ground DI1 DO0 DO1 1 2 3 4 5 6 Max. Fault Alarm Loading: 24V, 1A 1 2 3 4 5 6 DC Input: 48-54V...
4. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to RJ45 type serial (console) port of the Industrial Managed Switch. The console port of the Industrial Managed Switch is DCE already, so that you can connect the console port directly through PC without the need of null modem. IGS Industrial Managed Switch PC/Workstation with Terminal Emulation Software...
4.1 Logging on the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”. Then, the following message asks to login user name and password. The factory default user name and password are shown as follows and the login screen in Figure 4-3 appears.
Page 10
(2) This device must accept any interference received, including interference that may cause undesired operation. Made in Taiwan PLANET Technology Corp. Figure 4-4: Industrial Managed Switch MAC ID Label Enter the default username and password, then set a new password according to the rule-based prompt and confirm it. Upon success, press any key to return to the...
4.2 Configuring IP Address via Console The Industrial Managed Switch is shipped with default IP address shown below: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows: Display of the current IP Address 1. At the “#” prompt, enter “show ip interface brief”. 2. The screen displays the current IP address shown in Figure 4-6. Figure 4-6: IP Information Screen ...
4.3 Storing the Current Switch Configuration 1. At the “#” prompt, enter the following command and press <Enter>. # copy running-config startup-config Figure 4-8: Saving Current Configuration Command Screen If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address. If you are not familiar with the console command or the related param- eter, enter “help” anytime in console to get the help description.
5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Page 14
Default User Name: admin Default Password: admin Figure 5-2: Login Screen The following web screen is based on the IGS-5225-8P2S2X; the display of the IGS-5225-8T2S2X is the same as that of the IGS-5225-8P2S2X. 3. After entering the password, the main screen appears as shown in Figure 5-6. The following web screen is based on the firmware version of July of 2024 or after. 4. When the following dialog box appears, please enter the default user name “admin”...
Page 15
(1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. PLANET Technology Corp. Made in Taiwan Figure 5-3: Industrial Managed Switch MAC ID Label Figure 5-4: Login Screen 6. After logging in, you will be prompted to change the initial password to a perma-...
Page 16
7. Enter the default username and password, then set a new password according to the rule-based prompt and confirm it. Upon success, press any key to return to the login prompt. Log in with "admin" and the “new password” to access the Web interface. Figure 5-6: Web Main Screen of Industrial Managed Switch 8. The Switch Main Menu is shown on top left of the Web page, and the functions are shown on the left to configure the Industrial Managed Switch.
5.2 Saving Configuration via Web In the Industrial Managed Switch, the running configuration file stores in the RAM. In the current version, the running configuration sequence of running-config can be saved from the RAM to FLASH by executing save startup config command, so that the running configuration sequence becomes the startup configuration file, which is called configuration save.
Page 18
2. Or you can press the “Save Configuration” button. 3. Press the “Save Configuration” button to save.
Be noted that all the previous setups will be disappeared after the factory default reset is made. Console 115200 Alarm Ring R.O. 1G/2.5G 1G/2.5G 10/100/1000T 1000 10/100 LNK PoE-in-Use PoE Usage 240W 180W 120W 802.3at PoE+ Reset Button IGS-5225-8P2S2X Reset Figure 6-1: IGS-5225-8T2S2X/IGS-5225-8P2S2X Reset Button...