PRODUCT DESCRIPTION
TM
Hubbell Arc-Guard
DC plug and connector are intended for
use to supply the electromagnets on magnetic cranes. They
are engineered to prevent connection and disconnection of
the plug and connector prior to disconnecting supply power
to the connector.
NOTICE: For installation by a qualified electrician in accord-
ance with national and local electrical codes and the following
instructions.
CAUTION: Ensure device type and rating are suitable for the
application and installed in accordance with site safety proto-
cols.
CAUTION: Ensure conductors are sized to comply with Nation-
al Electrical Code® Table 400.5(A)(1) or 400.5(A)(2)
WARNING: Only for use in systems where magnet induced
voltage is limited to 700 volts-peak maximum. Refer to mag-
net controller specifications.
CAUTION: The connector must be positioned vertically above
the plug for best waterproof protection.
WARNING: Installed connector and plug MUST be properly
secured to support structure with adequate strain relief such
as the Kellems Grip strain relief shown in Table 1.
WARNING: Only use multi-conductor round electrical cords
listed below.
Ratings:
Electrical: 100A 250VDC
Enclosure: NEMA 3R (when connector is positioned vertically
above plug)
Cord types: Sizes in Table 1
Cord Type
Cord Dia. (in.)
#6/2C Type W
0.91
#6/3C SOOW
0.98
#6/3C Type W
1.01
#4/2C Type W
1.02
#4/3C Type W
1.13
#4/3C SOOW
1.14
#2/2C Type W
1.21
#2/3C Type W
1.32
Scan code for video instructions:
Wiring Device-Kellems ● Hubbell Incorporated (Delaware) ● Shelton, CT 06484 ● 1-800-288-6000
www.hubbell-wiring.com
TM
Arc-Guard
Interlocked Magnet Crane Plug and Connector
Plug Catalog Number HBL100MAGM
Connector Catalog Number HBL100MAGF
Installation and Operation Instructions
Kellems Grip P/N
02202015
02202015
02202017
02202017
02202017
02202017
02202017
02202018
Table 1
WIRING INSTRUCTIONS FOR PLUG AND CONNECTOR
CAUTION: RISK OF ELECTRIC SHOCK. Disconnect power before
installing.
WARNING: To avoid the plug's exposed electrical contacts from
being energized in an unmated condition,
the plug to the load (magnet) side. The connector
must always be connected to the power source. Do
not reverse this order.
Step 1: Remove bracket screws (4) holding the brackets and
boots to the plug and connector bodies. Separate the bodies
from the boots. See Figure 1.
.
Step 2: Remove cover screws (4) from plug or connector and set
aside cover. See Figure 1.
Step 3: Determine corresponding ring number for the cord type
and size used. See Table 2 and Figure 2. Apply wire pulling lubri-
cant to end of boot and cable for ease of insertion.
©2023 Hubbell Incorporated
Figure 1
Ring Number
Diameter For Cord Type
1
(No cut)
.90"
2
1.00"
3
1.20"
4
1.32"
Table 2
Figure 2
PD2934 Rev3 2023-11-15
always connect
#6/2C Type W
#6/3C SOOW
#6/3C Type W
#4/2C Type W
#4/3C Type W
#4/3C SOOW
#2/2C Type W
#2/3C Type W

Advertisement

loading
Need help?

Need help?

Do you have a question about the Arc-Guard HBL100MAGM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hubbell Arc-Guard HBL100MAGM

  • Page 1 #4/3C Type W 1.00” #4/3C SOOW 1.20” #2/2C Type W 1.32” #2/3C Type W Table 2 Scan code for video instructions: Figure 2 Wiring Device-Kellems ● Hubbell Incorporated (Delaware) ● Shelton, CT 06484 ● 1-800-288-6000 www.hubbell-wiring.com ©2023 Hubbell Incorporated PD2934 Rev3 2023-11-15...
  • Page 2 (2) this device must accept any interference received, including interference that may cause undesired operation. Wiring Device-Kellems ● Hubbell Incorporated (Delaware) ● Shelton, CT 06484 ● 1-800-288-6000 www.hubbell-wiring.com ©2023 Hubbell Incorporated PD2934 Rev3 2023-11-15...

This manual is also suitable for:

Arc-guard hbl100magf