400-005 and 400-006 RigCom Stations
Confidentiality Notice .....................................................................................................................1
General Information .......................................................................................................................1
Important Safety Instructions .........................................................................................................2
Installation ......................................................................................................................................2
Speaker Horn Assembly ......................................................................................................................... 3
Mounting .................................................................................................................................................. 3
Hardware Configuration ........................................................................................................................ 3
Internal .................................................................................................................................................. 3
External ................................................................................................................................................. 3
Wiring ...................................................................................................................................................... 5
System Wiring ...................................................................................................................................... 5
Station Wiring ....................................................................................................................................... 5
System Line Balance ............................................................................................................................. 6
Field Connections ................................................................................................................................. 8
Cover Installation .................................................................................................................................. 10
Operation .......................................................................................................................................10
Common Line System ........................................................................................................................... 11
Master/Slave System ............................................................................................................................. 11
Maintenance ..................................................................................................................................12
F1/F2 Fuses ............................................................................................................................................ 12
Troubleshooting .................................................................................................................................... 12
Replacement Parts and Accessories .................................................................................................... 13
Specifications ................................................................................................................................13
AC Power ............................................................................................................................................... 13
DC Power ............................................................................................................................................... 13
Amplifier PCBA .................................................................................................................................... 13
Speaker (Model 400-005 Only) ............................................................................................................ 13
Mechanical ............................................................................................................................................. 14
Environmental ....................................................................................................................................... 14
Approvals .......................................................................................................................................14
Appendix A-Interfacing a Model 400-005 RigCom Station to EZ Page Stations ......................................14
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 ◼ 800-492-1212 ◼ Fax: 610-796-5954
V
ISIT WWW
G A I - T R O N I C S
A H U B B E L L C O M P A N Y
T
A B L E O F
.
-
.
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
®
C
O N T E N T S
Pub. 42004-561A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAI-TRONICS 400-005 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hubbell GAI-TRONICS 400-005

  • Page 1: Table Of Contents

    Pub. 42004-561A G A I - T R O N I C S ® A H U B B E L L C O M P A N Y 400-005 and 400-006 RigCom Stations A B L E O F O N T E N T S Confidentiality Notice ........................1 General Information ........................1...
  • Page 2: Confidentiality Notice

    Pub. 42004-561A G A I - T R O N I C S ® A H U B B E L L C O M P A N Y 400-005 and 400-006 RigCom Stations Confidentiality Notice This installation, operation, and maintenance manual contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
  • Page 3: Important Safety Instructions

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 2 of 16 Important Safety Instructions • Read, follow, and retain instructions—Read and follow all safety and operating instructions before installing or operating this unit. Retain instructions for future reference. • Heed warnings—Adhere to all warnings on the unit and in the operating instructions. •...
  • Page 4: Speaker Horn Assembly

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 3 of 16 CAUTION —Do not install this equipment in hazardous areas other than those indicated in the Approvals section of this manual. Such installation may cause a safety hazard and consequent injury or property damage. The mounting location must be flat and provide proper clearance, rigidity, and strength to support the enclosure and all contained devices.
  • Page 5 Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 4 of 16 Figure 2. Model 400-005/400-006 Mounting Detail and Conduit Entries GAI-TRONICS CORPORATION 3030 KUTZTOWN RD., READING, PA 19605 G AI-TRONICS SERVICE CENTERS: www.g ai-t ro nics.com In USA: 1-800 -492 -1 21 2 Out side USA : 1-61 0-7 77-137 4 No.
  • Page 6: Wiring

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 5 of 16 Wiring System Wiring The maximum line length for the complete system, while still maintaining maximum output signal, is 15,000 feet for a system with less than ten stations; based on No. 18 AWG wire, equidistant station spacing, and one station in talk mode at a time.
  • Page 7: System Line Balance

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 6 of 16 Figure 5. RigCom Station PCBA 5. Attach the wires to the terminal blocks, on the PCBA, within the enclosure (see Figure 5 and the Field Connections section for connection points and descriptions). 6.
  • Page 8 Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 7 of 16 : The junction box must be suitable for the applicable hazardous location where it is located. Figure 6. System Cable (wiring less than 4000 feet long) Figure 7. Master/Slave System (wiring greater than 4000 feet long) P:\Standard IOMs - Current Release\42004 Instr.
  • Page 9: Field Connections

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 8 of 16 Field Connections TB1—Speaker Terminal Block Table 1. Speaker Output Connection at Terminal Block TB1 Name Pin No. Description 16-ohm terminal for external speaker connection 8-ohm terminal for external speaker connection common terminal for external speaker connection TB2—AC Power Terminal Block Table 2.
  • Page 10 Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 9 of 16 TB4—Audio and Low Voltage Control Terminal Block Table 4. Audio Signal and Low Voltage Control Connections at Terminal Block TB4 Name Pin No. Description Positive terminal for the auxiliary microphone. –...
  • Page 11: Cover Installation

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 10 of 16 Cover Installation 1. Inspect and clean the machined flange flame joint surfaces of both the cover and box. Surfaces must be smooth, free of nicks, scratches, dirt, or any foreign particle build-up that may prevent a proper seal.
  • Page 12: Common Line System

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 11 of 16 Common Line System All stations are on a common audio path and are normally in listen mode in the common line configuration. Activation of a station’s push-to-talk toggle switch supplies its audio signal to the common audio path.
  • Page 13: Maintenance

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 12 of 16 Maintenance Contact a regional service center for a return authorization number (RA#) if the equipment requires service. Equipment must be shipped prepaid to GAI-Tronics with a return authorization number and a purchase order number.
  • Page 14: Replacement Parts And Accessories

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 13 of 16 Replacement Parts and Accessories Contact GAI-Tronics for replacement part information. Table 5. Available Accessories for RigCom Stations Part No. Description 12801-002 auxiliary microphone 51052-003 auxiliary footswitch 10438-002 microphone I.S. barrier kit (contains 12801-002 auxiliary mic assembly) 12807-001 connector kit 60075-001...
  • Page 15: Mechanical

    Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 14 of 16 Mechanical Construction/finish ..................cast aluminum/tumblfast finish Mounting ..............wall or column, four 7/16-inch mounting feet with slots Connections....................... plug-in style terminal blocks Conduit entries bottom: ......................... two, 3/4-inch NPT top: ................... one, 1/2-inch NPT (Model 400-006 only) Dimensions .............
  • Page 16 Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 15 of 16 The following are wiring diagrams are for the different configurations of a RigCom/EZ Page system: Figure 10. Master/Slave Unbalanced Configuration with the Model 400-005 as Master Figure 11. Master/Slave Unbalanced Configuration with the Model 400-005 as Slave Figure 12.
  • Page 17 Pub. 42004-561A 400-005 and 400-006 RigCom Stations Page 16 of 16 Figure 13. Master/Slave Balanced Configuration with Model 400-005 as Master Figure 14. Master/Slave Balanced Configuration with Model 400-005 as Slave Figure 15. Balanced Common Line Configuration P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-561A.docx 04/22...
  • Page 18 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document.

This manual is also suitable for:

Gai-tronics 400-006

Table of Contents