Authenticator Diagnostics - D-Link DGS-3324SRi User Manual

Xstack stackable gigabit layer 3 switch
Hide thumbs Also See for DGS-3324SRi:
Table of Contents

Advertisement

Authenticator Diagnostics

This table contains the diagnostic information regarding the operation of the Authenticator associated with each port. An
entry appears in this table for each port that supports the Authenticator function. To view the Authenticator Diagnostics,
click Monitoring > Port Access Control > Authenticator Diagnostics.
The user can specify a switch in a switch stack using that switch's Unit ID by using the pull down menu in the top left
hand corner. The user may also select the desired time interval to update the statistics, between 1s and 60s, where "s"
stands for seconds. The default value is one second.
The following fields can be viewed:
Parameter
Port
Connect Enter
Connect LogOff
Auth Enter
Auth Success
Auth Timeout
Auth Fail
Auth Reauth
xStack Stackable Gigabit Layer 3 Switch Manual
Figure 9- 22. Authenticator Diagnostics window
Description
The identification number assigned to the Port by the System in which the Port
resides.
Counts the number of times that the state machine transitions to the CONNECTING
state from any other state.
Counts the number of times that the state machine transitions from CONNECTING to
DISCONNECTED as a result of receiving an EAPOL-Logoff message.
Counts the number of times that the state machine transitions from CONNECTING to
AUTHENTICATING, as a result of an EAP-Response/Identity message being
received from the Supplicant.
Counts
the
number
AUTHENTICATING to AUTHENTICATED, as a result of the Backend Authentication
state machine indicating successful authentication of the Supplicant (authSuccess =
TRUE).
Counts
the
number
AUTHENTICATING to ABORTING, as a result of the Backend Authentication state
machine indicating authentication timeout (authTimeout = TRUE).
Counts
the
number
AUTHENTICATING to HELD, as a result of the Backend Authentication state
machine indicating authentication failure (authFail = TRUE).
Counts
the
number
AUTHENTICATING to ABORTING, as a result of a reauthentication request
(reAuthenticate = TRUE).
of
times
that
the
of
times
that
the
of
times
that
the
of
times
that
the
267
state
machine
transitions
state
machine
transitions
state
machine
transitions
state
machine
transitions
from
from
from
from

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dgs-3324srDxs-3326gsrDxs-3350sr

Table of Contents