Page 1
DPO8000 series Digital oscilloscope User Manual 202304...
Page 2
Hantek certified DPO series oscilloscope to meet China's national industry standards and has passed the CE certification. Contact us If you have any questions when using the products of Qingdao Hantek Electronic Co., LTD., you can obtain service and support through the following ways: Email: service@hantek.com, support@hantek.com...
Utility label before clicking Language menu. Document content conventions: DPO8000 series tablet oscilloscope consists of the following models. Unless otherwise specified, this manual uses DPO8054E as an example to describe the DPO8000 series and basic operations. Model Bandwidth Channel Signal source...
Horizontal direction pinch can adjust the horizontal gear of the waveform. Figure 4.13 Pinch & Stretch Gesture Rectangle Drawing: Click on [Hantek], then click on the AreaSel to switch to rectangular drawing mode. Drag your finger on the screen to draw a rectangle,. Move your finger away from the screen, and a menu will appear on the screen.
Segmented menu, and enter the settings menu. Alternatively, click on the navigation icon [Hantek] in the upper left corner of the screen and select segmented acquisition. Entering the settings menu and lighting up the label means opening segmented collection. The segmented collection results appear in the middle of the screen.
⚫ Click [Math] in the button area to enter the mathematical operation menu. ⚫ Click on the navigation icon [Hantek] in the upper left corner of the screen, select FFT, and enter the FFT menu. This chapter includes: ⚫...
The menu can be accessed through the following methods: ⚫ Click on the button area [Meas] to enter the measurement menu. ⚫ Click on the navigation icon [Hantek] in the upper left corner of the screen, select Measure, and enter the measurement menu. This chapter includes: ⚫...
In [Utility] -> Pass/Fail, enter the Pass/Fail function menu. ⚫ Click on the navigation label [Hantek] in the upper left corner of the screen, select Pass/Fail, and enter the Pass/Fail function menu. 13.4.1 To Enable or Disable the Pass/Fail Test Function...
⚫ Click on the navigation icon [Hantek] in the upper left corner of the screen, select shortcut operations, and enter the settings menu. Quick setting include: Save Image, Save Wave, Save Setup, All Measure, Stat Reset, Record, Save Group.
Self Check menu. ⚫ Click on the navigation icon [Hantek] in the upper left corner of the screen, select Self Check, and enter the Self Check menu. The self-test options include Key Test, Screen Test, and Touch Test.
Protocol 15 Protocol This series of machines support a variety of protocol generator functions, click the navigation icon [Hantek] in the upper left corner of the screen, select Protocol, enter the setting menu. The contents of this chapter include: ⚫...
Burst menu tab to manually trigger once. 15.3 CAN Protocol Click the navigation icon [Hantek] to open the protocol generator menu. Type: Click the Type menu tab and select the "CAN" type for specific Settings. After the protocol generation type is selected, the menu changes to the CAN Settings menu.
Burst menu tab to manually trigger once. 15.5 IIC Protocol Click the navigation icon [Hantek] to open the protocol generator menu. Type: Click the Type menu tab and select the "IIC" type for specific Settings. After the protocol generation type is selected, the menu changes to the IIC Settings menu.
⚫ Click on the navigation icon [Hantek] in the upper left corner of the screen, select the frequency counter, and enter the settings menu. After enabling the frequency meter function, enter the frequency meter settings menu and select the signal source and measurement item.
Click the key area [Analyze] -> to enter the DVM setting menu. ⚫ Click the navigation icon [Hantek] in the upper left corner of the screen, select the digital voltmeter, and enter the setting menu. DVM: Click the menu label of DVM, select to turn on or off DVM function, select to turn on DVM, as shown in the figure below, including signal source, channel mode, voltage value, calibration, etc.
Check if the fuse is intact. If a fuse needs to be replaced, please use a fuse that meets the specifications of this product. If the button board still does not light up, please contact Hantek technical support department in a timely manner.
Page 255
Check if the oscilloscope is close to a strong magnetic field. If it is close to a strong magnetic field, please stay away first. If you still cannot use the touch screen, please contact Hantek technical support department in a timely manner.
During the warranty period, if the product is proved to be defective, Hantek will repair or replace the product free of charge. Please refer to the description on Hantek official website for detailed warranty regulations.
Need help?
Do you have a question about the DPO8000 Series and is the answer not in the manual?
Questions and answers