Download Print this page

SmartSafe iSmartEV EC100 Quick Reference Manual

Advertisement

Quick Links

Statement: Pictures illustrated herein are for reference only, We reserve the right to modify this Quick Reference Guide.
iSmartEV EC100 is a current clamp developed by SMARTSAFE for the detection
of new energy vehicles. It needs to be used with detection equipment (such as
iSmartEV P01). The current clamp has small volume, high accuracy and stable
performance, and supports AC / DC current test and DC voltage test.
+
1. Jaw
φ16mm×18mm
2. Direct Current Positive Input Indication
3. Clamp Mouth
4. Trigger
Control opening and closing of clamp head.
5. Indicator
Power: Power Indicator. It illuminates after power-on.
BT: Bluetooth Indicator. It flashes when communicating with
diagnostic equipment.
LO BAT: Battery Indicator. It illuminates when the battery is low.
6. Power Switch
7. Rope Chain Hole
8. Aviation Socket
9. Illuminating Lamp
10. Illuminating Lamp Switch
11. ZERO Button
When measuring DC current, zero adjustment
shall be conducted before measurement.
12. Battery Cover Fixing Screw
13. Battery Cover
Main Unit
Function
AC / DC current test and DC voltage test
Battery
9V dry battery
Test Mode
Clamp CT, non-contact measurement
Jaw Size
φ16mm×18mm (outer diameter of clampable wire)
Input Range
0~200A AC/DC
Resolution
1mA AC/DC
Accuracy
±3%FS (23℃±5℃, below 75%rh)
The ZERO button can be used for zero adjustment to eliminate the
Zero Adjustment
interference of geomagnetic field and external electric field.
Frequency Response
DC~50kHz
±48V DC
Voltage Test
When the battery is low, the LO BAT indicator on the current clamp will be on.
Please shut down and replace the battery in time. Use a cross screwdriver to open
the battery cover when installing the battery. Pay attention to the polarity of the
battery to avoid damaging the current clamp. Please use 9V dry battery for replace-
ment. When the current clamp is not used for a long time, take out the battery.
Test Clip
9V Square Battery

Advertisement

loading
Need help?

Need help?

Do you have a question about the iSmartEV EC100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SmartSafe iSmartEV EC100

  • Page 1 Statement: Pictures illustrated herein are for reference only, We reserve the right to modify this Quick Reference Guide. iSmartEV EC100 is a current clamp developed by SMARTSAFE for the detection of new energy vehicles. It needs to be used with detection equipment (such as iSmartEV P01).
  • Page 2 Statement: Pictures illustrated herein are for reference only, We reserve the right to modify this Quick Reference Guide. 4. Ensure that the current clamp is not in use. Press the ZERO button on the current clamp until the reading on the screen is 0. Notes: The effect of external electric field or geomagnetic field on the current clamp can be eliminated by using the 1.Start the Current Clamp app at the detection equipment and enter the following interface.