Advertisement

Quick Links

www.newsmartsafe.com
iSmartEV RT100 User Manual
Copyright Information
Copyright © 2021 by SHENZHEN SMARTSAFE TECH CO.,LTD.
All rights reserved. No part of this publication may be reproduced,
stored in a retrieval system, or transmitted in any form or by any
means, electronic, mechanical, photocopying, recording or
otherwise, without the prior written permission of SMARTSAFE.
Neither SMARTSAFE nor its affiliates shall be liable to the
purchaser of this unit or third parties for damages, losses, costs,
or expenses incurred by purchaser or third parties as a result of:
Accident, misuse, or abuse of this unit, or unauthorized
modifications, repairs, or alterations to this unit, or failure to
strictly comply with SMARTSAFE operating and maintenance
instructions. SMARTSAFE shall not be liable for any damages or
problems arising from the use of any options or any consumable
products other than those designated as Original SMARTSAFE
Products or SMARTSAFE Approved Products by SMARTSAFE.
All information, specifications and illustrations in this manual are
based on the latest information available at the time of printing.
SMARTSAFE reserves the right to make changes at any time
without prior written or oral notice.
Trademark Information
is
a
registered
trademark
of
SHENZHEN
SMARTSAFE TECH CO.,LTD. in China and other countries. All
other SMARTSAFE trademarks, service marks, domain names,
logos, and company names referred to in this manual are either
trademarks, registered trademarks, service marks, domain names,
logos, company names of SMARTSAFE or are otherwise the
property of SMARTSAFE or its affiliates. In countries where any
of the SMARTSAFE trademarks, service marks, domain names,
logos and company names are not registered, SMARTSAFE
I

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iSmartEV RT100 and is the answer not in the manual?

Questions and answers

Summary of Contents for SmartSafe iSmartEV RT100

  • Page 1 SMARTSAFE. Neither SMARTSAFE nor its affiliates shall be liable to the purchaser of this unit or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of:...
  • Page 2 You may not use any trademark, service mark, domain name, logo, or company name of SMARTSAFE or any third party without permission from the owner of the applicable trademark, service mark, domain name, logo, or company name. You may contact SMARTSAFE by visiting the website at www.newsmartsafe.com, or writing to...
  • Page 3 RT100 User Manual damage to the tester. Conventions The following conventions are used in this manual. Hazards To avoid possible serious or fatal damage under certain conditions and operations. Do not measure circuits with AC/DC voltage above 600V.
  • Page 4 RT100 User Manual Notes Helpful information is presented to avoid damage to the tester and to make accurate measurements. Before measuring resistance, the circuit to be measured must  be completely discharged and isolated from the power circuit.
  • Page 5: Table Of Contents

    RT100 User Manual Contents 1. Product Introduction ..............1 1.1 Overview .................1 1.2 Packing List ................1 1.3 Composition ................2 1.4 Technical Parameters ............4 2. Operating ................... 6 2.1 Charging and On/Off .............. 6 2.1.1 Charging ................. 6 2.1.2 Turn On/Off ..............6...
  • Page 7: Product Introduction

    With microcomputer technology design as the core, and a combination of large-scale integrated circuit and digital circuit, iSmartEV RT100 insulation tester is equipped with powerful measurement and data processing software; thus, it can complete measurement of the insulation resistance, voltage, and other parameters.
  • Page 8: Composition

    RT100 User Manual www.newsmartsafe.com iSmartEV RT100 insulation tester X 1  Switching Power Supply X 1  Test Clip X 3  User Manual X 3  Packing list X 1  1.3 Composition Name Description Earth Port Connected to a green single-cord wire.
  • Page 9 RT100 User Manual : When the insulation resistance is measured periodically, it is used to decrease the measurement duration; When the comparative measurement mode is used to measure the insulation resistance, it is used to decrease the resistance comparison value.
  • Page 10: Technical Parameters

    RT100 User Manual www.newsmartsafe.com Indicator Calibration For tester verification tests and standard resistance Terminal calibration. USB Type-C Reserved expansion port. Port For connection of the power adapter. Warning: Please use the attached power adapter for charging. We will not be responsible for any damage or loss...
  • Page 11 RT100 User Manual  AC/DC Voltage Testing Voltage Type DC Voltage AC Voltage Measurement Range ±30~±600V 30~600V Resolution Measurement Accuracy ±2% ±2% Note: Under any test voltage, if the measured resistance is less than 10MΩ, do not continuously measure for more than 10 seconds.
  • Page 12: Operating

    RT100 User Manual www.newsmartsafe.com 2. Operating 2.1 Charging and On/Off 2.1.1 Charging Note: After using the tester for the first time or not using the tester for a long time, the tester may fail to start up because of low battery. Please charge the tester for a period before trying to start up.
  • Page 13: Display

    RT100 User Manual 2.2 Display Name Name Battery Indicator Continuous Measurement Prompt Scale Negative Pole Symbol High Voltage Prompt DC Voltage Symbol Buzzer Symbol AC Voltage Symbol Output Voltage Timing Display Pass (Pass the Comparative Unit Symbol Measurement) Prompt...
  • Page 14: Ac/ Dc Voltage Measurement

    RT100 User Manual www.newsmartsafe.com continuous measurement mode is preset when startup, and the output voltage is 500V. (2) Please make sure that the tester is fully charged (if the battery icon is blank, it needs to be charged before testing).
  • Page 15 RT100 User Manual (2) Insert the red test clip into the LINE port on the tester and the green test clip into the Earth port on the tester. (3) Connect the red and green alligator clips to the circuit to be tested.
  • Page 16: Insulation Resistance Measurement

    RT100 User Manual www.newsmartsafe.com Note: Do not input a voltage higher than 600V or 600Vrms. Measuring higher  voltages risks may damage the tester. Special attention should be paid to avoid electric shock when measuring high  voltages. After completing all measurement, disconnect the test clip from the circuit to ...
  • Page 17 RT100 User Manual object and output the voltage from the LINE port. (4) Select the following insulation resistance measurement mode. After the system is powered on, the system enters the  insulation resistance continuous measurement mode by default. Press to select the output voltage and press TEST for 1 second to start measurement.
  • Page 18 RT100 User Manual www.newsmartsafe.com The timer area of the screen starts to display a countdown. The system will automatically end the measurement at the set time. Press the COMP button to enter the insulation resistance  comparative measurement mode, and the comparative measurement prompt will appear on the screen.
  • Page 19: Single-Point Calibration Of Onboard Resistance

    RT100 User Manual Schematic Diagram of Insulation Resistance Measurement Mode Switching 2.3.3 Single-point calibration of onboard resistance After using the tester for a period, it is recommended to calibrate the onboard resistance. The specific steps are as follows: (1) Connect the test clip to the resistance calibration terminal on the tester as shown below.
  • Page 20 RT100 User Manual www.newsmartsafe.com (2) Under the startup state, long press the COMP button to enter the calibration state of 200MΩ resistance. The screen will display the character of CAL and the resistance value of 200MΩ.
  • Page 21 RT100 User Manual (3) Long press the TEST button to start the measurement, and then press the TEST button to finish the measurement when the value is stable. (4) Long press the COMP button for 5 seconds to exit the calibration, then the calibration is complete.
  • Page 22: Maintenance

    RT100 User Manual www.newsmartsafe.com 3. Maintenance • Please use clean water wet soft cloth or sponge (without clear water residue) to wipe the surface of the casing. • Do not immerse the tester in water to avoid damaging it.
  • Page 23: Warranty

    • Customer Service Center If the equipment needs to be repaired, please send the equipment to SmartSafe, together with the purchase invoice and problem description. If the equipment is within the scope of the warranty, SmartSafe offer free maintenance; If the...

Table of Contents