Functional test
Test the function before every use.
Action:
Push both handles
towards below.
Let one handle
loose, then the
other.
Let both handles
loose.
Check the oil level before every use –
see chapter "Maintenance".
Splitting
• Place the log on the table, hold it with
both handles, press the handles down.
As soon as the splitting knife enters the
wood, push the handles down and to the
outside at the same time. This prevents
the wood from putting pressure on the
holder plates.
• Only split straight cut logs.
• Split the logs in vertical position.
• Never split in horizontal position or
across.
• Wear protective gloves when splitting.
Rational working method
-
Upper position approx. 5 cm above log.
-
Lower position approx. 10 cm above ta-
ble.
32
GB
Result:
Splitting knife goes
down to approx. 10
cm above the table.
Splitting knife stops
in the desired
position.
Splitting knife
returns to upper
position.
11. Electrical connection
Check electrical connection cables regularly
for damage. Ensure that the connecting ca-
ble is not attached to the mains when you
are checking it.
Electrical connecting cables must corre-
spond to the relevant VDE and DIN regula-
tions. Only use connecting cables with the
code H 07 RN.
The type designation must be printed on the
connecting cable by regulation.
Faulty electrical connecting cables
Insulation damage often occurs at electrical
connecting cables.
Causes include:
• Pinch points when connecting cables are
run through window or door gaps.
• Kinks resulting from incorrect attachment
or laying of the connection cable.
• Cuts resulting from running over the con-
necting cable.
• Insulation damage resulting from forceful-
ly pulling out of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables
must not be used as the insulation damage
makes them extremely hazardous.